Dynalco Monitoring TMP-200DC 24-Channel DC Powered Pyrometers, The TMP-200DC Multi-Point Digital Pyrometer measures the temperature of up to 24 points in any process. 24-channel temperature indicator is powered by 24 VDC. Accepts most popular grounded and ungrounded thermocouple types as well as 100 ohm platinum RTD, depending on model. Integral cold junction compensation. Dynalco serves a variety of customers in the Oil and Gas, Chemical Process, Construction and off-road equipment, Transportation, Power Generation, Marine, Mining, Water and Waste Water and Factory Automation Markets.

Another Article:

Dynalco Monitoring TMP-200DC  Features

  • Powered by 24VDC
  • Digital readout with 1° resolution
  • Integral 2-pole selector switch permits using grounded or ungrounded thermocouples
  • Fits existing cutouts and mounting holes of other popular pyrometers
  • Fully gasketed; rugged construction

Dynalco Monitoring TMP-200DC Specification

Display: 3-1/2 digit (–999 to +1999), 0.5″ high, liquid crystal display, 1° increment. Brightness increases with ambient light (no outdoors fadeout). Open thermocouple or RTD indicated by a number 1 in the thousands column; all other digits blanked.
Environment Temperature: 0°F to +165°F (–18°C to +74°C); 0.25% maximum effect on readout.

Reference : dynalco.com

Download : Datasheet

Dynalco Monitoring SPD Series Signal Powered Tachometer

Advertisements

Dynalco Monitoring  SPD Series Signal Powered Tachomete, Dynalco serves a variety of customers in the Oil and Gas, Chemical Process, Construction and off-road equipment, Transportation, Power Generation, Marine, Mining, Water and Waste Water and Factory Automation Markets.

Dynalco Monitoring  SPD Features

  • Signal and power derived totally from magnetic pickup or pulser.
  • Intrinsically safe. Can be used in hazardous environments with approved Dynalco pickups. (See THIRD PARTY APPROVALS, next page.)
  • No power supply connections. High immunity to electrical noise.
  • Can be field-calibrated.
  • High accuracy: 1 rpm resolution.
  • High shock and vibration resistance.
  • Standard SAE case size fits panels with 3-3/8 inch (86 mm) openings.
  • Gasketed and spray-proof.
  • Ideal for OEM use.
  • Can be paralleled with governors and/or speed switches.
  • Can share existing pickups or pulsers; draws only microamperes.
  • Ground-free terminals have no polarity; easy installation.

Another Article:

Dynalco Monitoring  SPD Spesification :

  1. External Power Requirements: All models are signal-powered. Lighted versions: 12 or 24 Vdc, depending on model.
  2. Display: Four active digits (0 to 9999), non-blinking LCD display; character height of 0.5 inches (14 mm). Display contrast increases with increasing ambient light.
  3. Input Valve Voltage: From pickups, pulsers, shaft encoders, etc.
    ‹ Minimum signal amplitude: 2.5 Vrms.
    ‹ Maximum permissible signal: 15 Vrms.
    The SPD-100 automatically limits pickup signals at approximately 10 volts peak-topeak. Input impedance is 100 Ω in series with a 6 volt Zener diode.
  4. Input Signal Frequency:
    Maximum input signal frequency of 20,000 Hz. Lowest frequency range limited by gate time and corresponding numerical display.
  5. Isolated Circuit: All circuitry is totally floating, i.e. totally isolated and insulated from the case and from ground.
  6. Operating Temperature Range: –5oF to +175oF (–20oC to +80oC).
  7. Storage: –40oF to +195oF (–40oC to +90oC).
  8. Vibration: MIL STD 810C; Method 514.2; Curve Q; Procedure V; Modified to 500 Hz upper limit. 5 Hz to 10 Hz @ 0.2 inches D.A.; 10 Hz to 18 Hz @ 1.0 g (peak); 18 Hz
    to 57 Hz @ 0.06 inches D.A.; 57 Hz to 500 Hz @ 10 g (peak).
  9. Accuracy: One rpm resolution; within 0.5% (0.1% typical at room ambient) under all combined environmental conditions.
  10. Gate Time Ranges: SPD-100 Series : field-selectable from 0.26 to 5.7 seconds. SPD-108 Series: field-selectable from 0.13 to 2.85 seconds.
    • This accommodates calibrations for an extremely broad range of corresponding pulses per second.
  11. Magnetic Pickups:
    Dynalco Magnetic Pickups M102 and M107 are used with the SPD-100 Series in most applications. Refer to Dynalco Magnetic Pickup brochure for various types and characteristics.
    For low-speed applications, or to permit operation with larger gaps, the ultrahigh sensitivity M142 can be used.
    For intrinsically safe applications Dynalco Controls offers various models, with the M202 and M134 the most frequently used.
  12. Weight: 1 lb (0.45 kg)

Dynalco Monitoring  SPD Series Signal Powered Tachometer :

  1. SPD-100 Tachometer
    • TACHOMETER: signal-powered, 4- digit, intrinsically safe, unlighted display
    • The SPD-100 is a solid- state, intrinsically safe tachometer. The gate time range (0.26 to 5.70 seconds) is field- programmable. It is well- sealed for rugged indoor and outdoor applications. It has 4-digit, unlighted, LCD display. CSA and ABS Type approved.
  2. SPD-100L Tachometer
    • TACHOMETER: signal-powered, 4- digit, lighted display
    • The SPD-100L is a solid- state tachometer. The gate time range (0.26 to 5.70 seconds) is field-programmable. It is well-sealed for rugged indoor and outdoor applications. It has 4-digit, lighted, LCD display.
  3. SPD-108 Tachometer
    • TACHOMETER: signal-powered, 4- digit, instrinsically safe, unlighted display, ½ gate time range of SPD-100
    • The SPD-108 is a solid- state, intrinsically safe tachometer with a gate time range (0.13 to 2.85 sec) that is field- programmable. It is well- sealed for rugged indoor and outdoor applications. It has 4-digit, unlighted, LCD display. CSA and ABS Type approved.
  4. SPD-108L Tachometer
    • TACHOMETER: signal-powered, 4- digit, lighted display, ½ gate time range of SPD-100
    • The SPD-108L is a solid- state, tachometer with a gate time range (0.13 to 2.85 sec) that is field-programmable. It is well-sealed for rugged indoor and outdoor applications. It has 4- digit, lighted, LCD display.

Reference : dynalco.com

Download : Datasheet

Dynalco Monitoring Catalyst Monitor Engine Monitoring & Controls

Advertisements

Dynalco Monitoring Catalyst Monitor Engine Monitoring & Controls, 6 Channel Monitor / Data Logger. Designed for catalyst monitoring and data logging on Spark Ignited and Diesel engines.

  • NSCR (3-way) & Oxidation (2-way) type catalysts

Dynalco was started in 1968 with three products and a goal of producing engineered solutions for the oil and gas industries. Today, Dynalco has become a worldwide industry leader, recognized for its high-quality instruments and controls used in the oil & gas, chemical, power, marine and construction industries. In October 2011 Dynalco was acquired by its sister company Barksdale, Inc. and is now part of Barksdale’s family of brands

Another Article:

The following parameters are monitored:

  • Catalyst Inlet / Outlet Temperatures plus Differential
  • Catalyst Inlet / Outlet Pressures plus Differential
  • Left Bank / Right Bank O2 Sensor Outputs for ensuring proper AFRC operation
  • Engine Hours (5-digit non-resettable)
  • Engine Speed
  • Can be configured to alarm if inlet temperature out of compliance
  • On-Board Data Logging of thousands of values with time / date stamp. Monitors catalyst inlet temperature based on 4 hour rolling average per RICE NESHAP requirements – data is saved to non-volatile flash memory
  • Modbus RS-485 Communications Protocol for communications w/ SCADA or DCS
  • CSA Class I, Division 2 Groups A, B, C & D approved
  • Fully programmable from front keypad
  • High capacity on board flash memory
  • Power loss will not erase memory
  • Log Reader software allows data download to PC with USB cable p/n 270A-13020

 

Dynalco Monitoring Catalyst Monitor Specification :

Electrical:

  • Supply Voltage: 10 – 36 VDC
  • Input Types: J, K type thermocouple
    • 4 – 20 mA
    • 0 – 1 VDC
    • 0 – 5 VDC
    • 0 – 10 VDC
    • Plus (1) pulsed input for RPM display
  • Output Type: (2) digital outputs rated 0.15 A @ 48 VDC
  • Scan Rate: All channels scanned in 100 milli-seconds
  • Accuracy: 0.2%
  • Mechanical:
    • ¼ DIN package (3 ½” width X 3 ½” height) for panel mount
    • Splash-proof front panel
    • Removable connectors on back of enclosure

 

Reference : dynalco.com

Download : Datasheet

Dynalco Monitoring D-100 Engine Monitoring & Controls

Advertisements

Dynalco Monitoring D-100 Engine Monitoring & Controls, New high resolution CANbus monitor to simply display your engine parameters. D-100 CANbus monitor offers J1939 compatibility for displaying engine performance parameters as well as providing over/under speed threshold protection. The D-100 can also monitor and display various types of
inputs to help measure parameters such as temperature, pressure, and RPM. Plus it can send output signals to trigger controls via 4 independent relays.

Another Article:

Dynalco Monitoring D-100 Features

  • High resolution 320 x 240 color LCD, clear high contrast screen
  • 7 analog, 2 digital, and 1 signal inputs
  • 4 relay outputs
  • Full sunlight readable with maximum brightness of 750 NIT (cd/m2)
  • User configurable single and quadruple screens
  • 5 soft keys provide easy, full local configuration
  • Select digital values, analog gauges, or both to meet your preference
  • Displays TIER 4 engine information
  • Alarms provide immediate visual and audible indications
  • Password protected to avoid unauthorized changes
  • IP66 enclosure rating

CANbus Engine Monitor Applications

  • CANbus Enabled Engines
  • CANbus Enabled Power Generators

Dynalco Monitoring D-100 General Spesification

  1. Enclosure Material : ABS
  2. Enclosure Rating : IP 66 front and IP 67 back
  3. Electrical Connection : Two 12-pin Deutsch DT04-12P receptacles
  4. Power Supply : 10 – 30 VDC
  5. Communications : RS232, 2 CANbus 2.0B, USB2.0
  6. Inputs:
    • (7) Analog Inputs :
      • Each input can be selected as:
      • 0 to 2.5 VDC
      • 0 to 10 VDC
      • 0 to 1K ohms
    • (2) Digital Inputs :  Switch contact to ground or open collector type sensor. Max frequency 50 Hz.
    • (1) Signal Input (Magnetic Pickup) 0 to 5000 Hz
  7. Outputs : 4 relay outputs rated 0.5 A
  8. Display: 3.5” Color TFT LCD, QVGA resolution 320 x 240 pixels
    • Viewing Angle : Wide horizontal and vertical viewing
      angle
    • Brightness : 750 NIT Full sunlight readable
  9. Temperature Range:
    • Operating: -40 to +158 °F (-40 to +70 °C)
    • Storage: -40 to +176 °F (-40 to +80 °C)
  10. Displayed Data If received from the engine and transmission*
    • Electrical, Fuel, Pressure, Temperature, Speed, Percentage, Time.
      *Refer to Operations Manual for more details
  11. Dimension : 3.3” diameter cutout 3.75” x 3.75” bezel [panel]

 

Reference : dynalco.com

Download : Datasheet

Quincy Compressor QRNG Natural Gas

Advertisements

Quincy Compressor QRNG Natural Gas,  Based on the proven performance of the QR-25, an air compressor with over 80 years of reliable service, but engineered exclusively for natural gas applications, the Quincy QRNG is constructed of heavy-duty cast iron for strength and durability. The cylinders are cast with horizontal cooling fins and machined to rigid tolerances. The Quincy QRNG features an advanced-design pressure lubrication system, rebuildable connecting rods and low-lift valves. Optional gas unloaders available.

QRNG Single & Two Stage Natural Gas Compressors, Our air compressor product lineup also includes rotary screw and reciprocating models for natural gas applications. The rotary screw options feature slow-turning, large-diameter motors that provide maximum operating efficiency. You’ll also find single-and two-stage reciprocating units that provide the strength and durability that is essential for natural gas use.

A natural gas compressor increases the pressure of a gas by reducing its volume. The natural gas enters the cylinder through the intake valves, where it is compressed and forced out through discharge valves. A gas air compressor is one form of natural gas compressor that is used in a wide range of industrial applications where either high pressure or lower volumes of gas are required. Examples include:

  • Petroleum refineries, natural gas processing plants and chemical plants: Used for the compression of intermediate and end-product gases
  • Industrial manufacturing and building: Provides compressed air that powers various pneumatic tools and equipment
  • Pipelines: Transporting natural gas from the production site to the end user
  • 2 – 600 hp
  • Single & two-stage recips
  • Direct drive rotaries
  • Over 20 models

Quincy Compressor QRNG Specification

A reciprocating gas compressor uses crankshaft-driven pistons to provide compression. The thrust is provided by a positive displacement pump that moves the gas through the system and enhances the gas’s pressure and density. Benefits of reciprocating gas compressors include their ability to produce high power and high pressure compressed gas, as well as the absence of an oil carryover problem. Reciprocating compressors also generally require a lower initial investment than other compressor types.

  • 2-34 hp
  • Single & Two-Stage
  • 400 psig max discharge

Reference : quincycompressor.com

Download : Datasheet

Quincy Compressor QVMS Vacuum Pump

Advertisements

Quincy Compressor QVMS Vacuum Pump, Quincy Compressor is your headquarters for high-quality, reliable vacuum pump units that are the product of nearly 100 years of unrivaled industry expertise. Quincy vacuum pumps are used by companies across the United States and around the world due to their uncompromising reliable and unbeatable performance. They’re also backed by superior 24-hour service and support from our extensive worldwide distributor network. There are various Quincy vacuum pump models to choose from, ensuring you’ll be able to find the right one for your applications.

QVMS 2-10 hp NFP 99 Compliant Direct Drive Vacuum Pump. The Quincy QVMS has been uniquely designed to meet your medical vacuum needs. Engineered for flexibility and easy installation, the QVMS features reliable, direct drive pumps and one-side access for necessary maintenance. Developed for hospital applications that demand high capacity and constant vacuum levels, at the heart of every QVMS is a Quincy QV rotary vane vacuum pump.

Another Article:

 

Quincy Compressor QVMS Vacuum Pump Spcification

  • its through standard doorway
  • Multi-stage demister/separator
  • Air cooled
  • Direct-drive pumps
  • Fully NFPA 99 compliant
  • 2-66 hp, 10-66 scfm
  • TEFC motors
  • NEMA 12 control panel
  • Gas ballast & anti-suck valves
  • Up to 2-Year Warranty Available

Reliable Operation When Lives Are on the Line

Any vacuum pump used in a hospital must be reliable, sanitary and easy to use. Engineered specifically for medical applications, the QVMS direct drive vacuum pump offers a host of features that make it ideal in any healthcare environment. These include:

  • An air-cooled design that operates continuously at vacuum levels as low as to 29.9” HgV (0.5 Torr), while avoiding the need for bulky, cumbersome water management systems
  • A totally enclosed, fan-cooled (TEFC) motor that is exceptionally reliable, shift after shift and day after day
  • A gas ballast and anti-suckback valve system that automatically accommodates changing vacuum levels
  • Built-in cooling fins and a spin-on fluid filter that allow for use in temperatures up to 104° F, or 40° C
  • A multi-stage demister/separator that filters outs impurities by achieving a minimum 99.9% fluid/air separation at all times

The QVMS vacuum pump is powered by a Quincy Compressor QV-series rotary vane vacuum pump and paired with either a horizontal or vertical mounted tank. Ten different configurations are available, delivering anywhere from 10-66 SCFM (2 to 10 HP) flow rates.

Every QVMS system is fully compliant with NFPA 99 standards for the safe installation, inspection, testing and maintenance of medical gas and vacuum systems. For detailed specifications, download the product brochure or contact Quincy directly to speak with one of our vacuum air experts.

World-Class Performance in a Small Package

Another notable feature of the QVMS direct drive vacuum pump is its small footprint. In facilities where space is at a premium, the unit’s modular design can be adapted to fit easily in any room. Small enough to move through any doorway, it is simple to install without requiring extensive infrastructure modification. This not only frees up floor space and eliminates clutter for a more streamlined workflow, it also keeps installation costs to a minimum — an important bonus for today’s increasingly budget-conscious healthcare providers.

Use the QVMS in any situation in which an NFPA-compliant direct drive vacuum pump is required. Many of our clients have purchased QVMS pumps as an economical and convenient alternative to central vacuum systems. For more information about potential applications, contact a Quincy representative directly.

 