E2E-X AC 2-Wire Models, Omron-Standard Proximity Sensor

E2E-X AC 2-Wire Models, Omron-Standard Proximity Sensor
E2E-X AC 2-Wire Models, Omron-Standard Proximity Sensor

These Proximity Sensors use high-frequency oscillation. They resist heat, chemicals, and water better than Rectangular Sensors. They are available in both shielded and unshielded models. Proximity Sensors are available in models using high-frequency oscillation to detect ferrous and non-ferrous metal objects and in capacitive models to detect non-metal objects. Models are available with environment resistance, heat resistance, resistance to chemicals, and resistance to water.

Features and Benefits

  • Standard Sensors for detecting ferrous
  • A wide array of variations. Ideal for a variety of
  • Models with different frequencies are also available to prevent mutual
  • Superior environment resistance with standard cable made of oil-resistant PVC and sensing surface made of a material that resists cutting
  • Useful to help prevent
  • Cable protector provided as a standard feature

Ratings and Specifications

Size Shielded

Item                 Model

M8 M12 M18 M30
Shielded Unshielded Shielded Unshielded Shielded Unshielded Shielded Unshielded
E2E-X1R5Y@ E2E-X2MY@ E2E-X2Y@ E2E-X5MY@ E2E-X5Y@ E2E-X10MY@ E2E-X10Y@ E2E-X18MY@
Sensing distance 1.5 mm ±10% 2 mm ±10% 5 mm ±10% 10 mm ±10% 18 mm ±10%
Set distance 0 to 1.2 mm 0 to 1.6 mm 0 to 4 mm 0 to 8 mm 0 to 14 mm
Differential travel 10% max. of sensing distance
Detectable object Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on page 18.)
Standard sensing object Iron,

8 ´ 8 ´ 1 mm

Iron, 12 ´ 12 ´ 1 mm Iron,

15 ´ 15 ´ 1 mm

Iron,

18 ´ 18 ´ 1 mm

Iron, 30 ´ 30 ´ 1 mm Iron,

54 ´ 54 ´ 1 mm

Response frequency 25 Hz
Power supply voltage (operating voltage range)*1  

24 to 240 VAC (20 to 264 VAC), 50/60 Hz

Leakage current 1.7 mA max.
 

Control output

Load current *2 5 to 100 mA 5 to 200 mA 5 to 300 mA
Residual voltage Refer to Engineering Data on page 19.
Indicators Operation indicator (red)
Operation mode (with sensing object approaching)  

Y1 Models: NO     Refer to the timing charts under I/O Circuit Diagrams on page 21 for details. Y2 Models: NC

Protection circuits Surge suppressor
Ambient temperature range *1*2 Operating/Storage: -25 to 70°C (with no icing or condensation) Operating/Storage: -40 to 85°C (with no icing or condensation)
Ambient humidity range Operating/storage: 35% to 95% (with no condensation)
Temperature influence ±10% max. of sensing distance at 23°C in the temperature range of -25 to 70°C ±15% max. of sensing distance at 23°C in the temperature range of -40 to 85°C,

±10% max. of sensing distance at 23°C in the temperature range of -25 to 70°C

Voltage influence ±1% max. of sensing distance at rated voltage in the rated voltage ±15% range
Insulation resistance 50 MÙ min. (at 500 VDC) between current-carrying parts and case
Dielectric strength 4,000 VAC (M8 Models: 2,000 VAC), 50/60 Hz for 1 min between current-carrying parts and case
Vibration resistance Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
 

Shock resistance

Destruction: 500 m/s2

10 times each in X, Y, and Z directions

 

Destruction: 1,000 m/s2 10 times each in X, Y, and Z directions

Degree of protection Pre-wired Models: IEC 60529 IP67, in-house standards: oil-resistant Connector Models: IEC 60529 IP67
Connection method Pre-wired Models (Standard cable length: 2 m) and Connector Models
 

 

Weight (packed state)

Pre- wired Models Model  

Approx. 60 g

 

Approx. 70 g

 

Approx. 130 g

 

Approx. 175 g

Connec- tor Models  

Approx. 15 g

 

Approx. 25 g

 

Approx. 40 g

 

Approx. 90 g

 

 

 

Materials

Case Stainless steel (SUS303) Nickel-plated brass
Sensing surface PBT
Clamp- ing nuts Nickel-plated brass
Toothed washer Zinc-plated iron
Accessories Instruction manual

Download Catalog: Standard Proximity Sensor E2E