Fluidwell F103 Weatherproof Flow Logger Totalizer and Display

Product Descriptions

Fluidwell F103 Totalizer Indicator is your best choice for flow monitoring applications. It is perfect for new installations and to replace existing flow analyzers in the field. Its rugged construction, unique plug-and-play design and attractive pricing makes the F103 the perfect flow logger for liquid and gas flow measurement in Class I, Division 2 hazardous areas.

It is the first F-Series with flow logging besides the various pulse and analog output signals. Even demanding applications are catered for with our base unit configuration.

The display shows flow rate and totals. A current day total (daily total) and 15 historical (previous) day totals can be enabled in the setup menu to be shown at the main display. On-screen engineering units can easily be configured from a comprehensive menu.

Fluidwell F103 Totalizer Indicator Data logging

When you need to easily monitor your flow measurements and historical data events over time, the optional flow logging feature is the perfect tool for you. It replaces the basic 15 previous day totals with a logger that registers 1500 interval, 600 daily and 724 event records.

The log interval can be user defined from every minute to daily. Events, such as cleared total, changed menu settings or factory reset can also be logged. Each log contains flow rate, total, acc. total, date and time stamp and log number.

The flow/data logging is optional available and when chosen, it replaces the basic 15 historical (previous) day totals. Each log contains the flow rate, total, acc. total, time stamp and log number. The log can be downloaded as .csv file with the free software tool.

Advantages

  • Robust aluminum or stainless steel 316L field enclosure (IP66, IP67 / Type4X) .
    It is so rugged, a truck can even stand on it!
  • CSA Class I, Division 2, Non-Incendive rating for the United States and Canada.
  • Familiar easy operation with the Fluidwell “Know one, know them all” configuration structure, saving time, cost and aggravation.
  • Very diverse mounting possibilities: walls, pipes, panels or directly onto outdoor sensors.
  • Easy configurable via PC with free downloadable remote configuration tool and special communication cable (ACE02/06/07).
  • Excellent pricing and fast delivery times.
Fluidwell F103 Display flow indicator Configuration
Fluidwell F103 Display flow indicator Configuration

Fluidwell F103 Totalizer Indicator Applications

  • The F103 is the perfect fit for new installations and to replace existing flow analyzers at liquid and gas flow measurement applications in Class I, Division 2 hazardous areas.
  • The optional data logging is for applications where you easily want to monitor daily operation and unexpected events over time.
  • The F-Series is your first and best choice for field mount indicators in safe and hazardous area applications. Especially in harsh weather conditions like rain, snow, sandy deserts, salty atmospheres and temperatures between -40°C to +70°C (-40°F to +158°F).
Fluidwell F103 Display flow loging application diagram
Fluidwell F103 Display flow loging application diagram

Fluidwell F103 Totalizer Indicator Features

  • Displays simultaneous linearized flow rate and total, as well as accumulated total, daily total and 15 previous day totals.
  • Flow logging to survey daily operation and unexpected events with 600 daily, 1500 interval and 724 event logs (optional).
  • Flow rate: seven 17mm (0.67″) or 8mm (0.31″) digits.
  • Total – resettable: seven 17mm (0.67″) digits.
  • Accumulated total – not resettable: eleven 8mm (0.31″) digits.
  • Separate engineering units for flow rate and total on the display.
  • The quick set-up allows easy configuration of the most often used settings.
  • Easy configurable via PC with free downloadable remote configuration tool and special communication cable (ACE02/06/07).
  • Smart K-factor configuration for volumetric or mass flow.
  • 15 linearization points for high accuracy at the full flow range.
  • Auto backup of settings and running totals in EEPROM memory.
  • Remote control input to reset total or to lock the “clear total” button.
  • LED backlight.
  • CSA Class I, Division 2, Non-Incendive rating for the United States and Canada.
  • GRP, Aluminum or high grade stainless steel enclosure.
  • Ambient temperature: -40°C to +70°C (-40°F to +158°F).
  • Various accessories are available for this product.
Fluidwell F103 Display flow indicator Configuration
Fluidwell F103 Display flow indicator Configuration

Product specifications

  • Display info : Flow rate, total, accumulated total and daily totals
  • Display size : 3.5” x 1.6”  ( 90 x 40 mm )
  • Number of digits f
    • for Total / Daily totals :  7 digits of 0.67” / 17 mm
    • for Accumulated total :  11 digits of 0.31” / 8 mm
    • for Flow rate :  7 digits of 0.31” / 8 mm
  • Measurement units :
    • For Total  : L, m3, US gal, igal, cf, Oil bbl, kg, ton, US ton, lb, nL, nm3
      or no unit.
    • for Flow rate : mL, L, m3, mg, g, kg, ton, US ton, US gal, igal, Oil, bbl, lb, cf, rev, none, scf, nm3, nL or p. /sec, /min, /hr, /day
    • Data protection : Manual back-up of Total Settings and Totals are automatically stored
  • Signal Inputs
    • Pulse type inputs:
      Non-isolated: Coil / sine wave, NPN/PNP, open collector, reed switch.
      Isolated : Active pulse input 3 – 30V DC
    • Turbine meter input (Coil), Isolated pulse input 3-30V DC max. max. 7kHz, NPN, PNP, Reed
  • Status Inputs
    • Isolated and non-isolated remote control: external reset for clearing total or to disable manual clearing by the keypad.
  • Signal Outputs
    • Pulse outputs
    • Function: Scaled pulse output according to linearized accumulated total (e.g. a pulse every 3.25 gallons) and unscaled pulse input retransmission.
      Max. frequency: 500Hz.
      Retransmission: Minimum pulse duration: 50µs, square wave output based on frequency of (sine wave or coil) input signal. Adjustable pulse length from 1 msec. Up to 10 seconds.
      Isolated Scaledpulse output : max. 50Hz. Pulse length user definable between 10msec up to 10 seconds.
    • Type: Two passive transistor outputs and one isolated passive solid state output.
    • Analog outputs
      • Function: Re-transmitting the linearized flow rate – the output can be scaled to any range (e.g. 200 L/min to 1200 L/min).
      • Type: One galvanically isolated, loop powered 4 – 20mA output.
  • Supply
    • Power Supply
      • Long life Lithium battery.
      • 4 – 20mA Loop-powered.
      • Basic: 6 – 30V DC.
      • 8 – 30V DC + sensor supply.
    • Sensor Supply
      • 3.2, 8.2, 12, 24V DC.
  • Communication
    • Function: Reading display information, clear total, reading / writing all configuration settings and data log extraction.
    • Type: RS232, RS485 2-wire Modbus ASCII / RTU.
    • Remote configuration via free downloadable remote configuration tool (see dropdown download above).
    • Free configuration : software and downloadable
  • Data logging :
    • 600 daily logs,
    • 1500 interval logs (configurable),
    • 724 event logs
  • Log data : Flow rate, total at contract hour. accumulated total. date / time stamp, log number
  • Ambient Temperature :  -40°F to 158°F (-40°C to 70°C)
  • Housing Classification :
    • IP class: Weatherproof Type 4X / IP67
    • Housing : aterial : Glass reinforced polymer. (Aluminium & Stainless Steelare available as well)
  • Hazardous Area
    • Non-Incendive  CSA: Class I, Division 2, Groups A, B, C, D T5.
    • Safe area according CE : optional.
  • Installation : Safely covered electronics and Plug-in connectors
  • Options : Backlight, Aluminium enclosure, Stainless Steel enclosure