Categories: Electrical Parts

Dynalco Catalyst 6 Channel Monitor – Data Logger

Overview

Dynalco was started in 1968 with three products and a goal of producing engineered solutions for the oil and gas industries. Today, Dynalco has become a worldwide industry leader, recognized for its high-quality instruments and controls used in the oil & gas, chemical, power, marine and construction industries.

In October 2011 Dynalco was acquired by its sister company Barksdale, Inc. and is now part of Barksdale’s family of brands. Monitors catalyst inlet temperature based on 4 hour rolling average per RICE NESHAP requirements – data is saved to non-volatile flash memory

Feature

Dynalco Monitoring Catalyst Monitor Engine Monitoring & Controls, 6 Channel

  • Monitor / Data Logger. Designed for catalyst monitoring and data logging on Spark Ignited and Diesel engines.
    • NSCR (3-way) & Oxidation (2-way) type catalysts
  • The following parameters are monitored:
    • Catalyst Inlet / Outlet Temperatures plus Differential
    • Catalyst Inlet / Outlet Pressures plus Differential
    • Left Bank / Right Bank O2 Sensor Outputs for ensuring proper AFRC operation
    • Engine Hours (5-digit non-resettable)
    • Engine Speed
  • Can be configured to alarm if inlet temperature out of compliance
  • On-Board Data Logging of thousands of values with time / date stamp
  • Modbus RS-485 Communications Protocol for communications w/ SCADA or DCS
  • CSA Class I, Division 2 Groups A, B, C & D approved
  • Fully programmable from front keypad
  • High capacity on board flash memory
  • Power loss will not erase memory
  • Log Reader software allows data download to PC with USB cable p/n 270A-13020

The following parameters are monitored:

  • Catalyst Inlet / Outlet Temperatures plus Differential
  • Catalyst Inlet / Outlet Pressures plus Differential
  • Left Bank / Right Bank O2 Sensor Outputs for ensuring proper AFRC operation
  • Engine Hours (5-digit non-resettable)
  • Engine Speed
  • Can be configured to alarm if inlet temperature out of compliance
  • On-Board Data Logging of thousands of values with time / date stamp. Monitors catalyst inlet temperature based on 4 hour rolling average per RICE NESHAP requirements – data is saved to non-volatile flash memory
  • Modbus RS-485 Communications Protocol for communications w/ SCADA or DCS
  • CSA Class I, Division 2 Groups A, B, C & D approved
  • Fully programmable from front keypad
  • High capacity on board flash memory
  • Power loss will not erase memory
  • Log Reader software allows data download to PC with USB cable p/n 270A-13020

Dynalco Monitoring Catalyst Monitor Specification :

Electrical:

  • Supply Voltage: 10 – 36 VDC
  • Input Types: J, K type thermocouple
    • 4 – 20 mA
    • 0 – 1 VDC
    • 0 – 5 VDC
    • 0 – 10 VDC
    • Plus (1) pulsed input for RPM display
  • Output Type: (2) digital outputs rated 0.15 A @ 48 VDC
  • Scan Rate: All channels scanned in 100 milli-seconds
  • Accuracy: 0.2%

Mechanical:

    • ¼ DIN package (3 ½” width X 3 ½” height) for panel mount
    • Splash-proof front panel
    • Removable connectors on back of enclosure

Reference : dynalco.com

Download : Datasheet

Other Article:

Inaparts Author