Kem Kuppers FOP and OPTV Fibreoptical Amplifier and Light Pulse Receiver

Description

The integral pickup detects the r.p.m. of the gears and the FOP provides a flow-proportional light pulse signal. The Kem Kuppers OPTV receiver will convert the light pulses into a current or voltage square wave signal.

Features

The Kem Kuppers FOP is a fibre-optic amplifier for KEM gear flow meters used in highvoltage applications. Its integral pickup detects the r.p.m. of the gears and the Kem Kuppers FOP provides a low-proportional light pulse signal. The Kem Kuppers OPTV receiver will convert the light pulses into a current or voltage squarewave signal which maybe used for evaluation.

Applications

  • Interference-free Pulse Detection
  • No Electrical Connection to OPTV Receiver
  • Anodised Aluminum Housing
  • Light Weight and Handy Design

Specifications

Technical Data FOP 60

Power SupplyLithium battery (exclusively use original batteries)
Battery LifetimeMax. 2 years with 24h-operation
Ambient Temperature-20 °C up to +50 °C [-4 °F up to +122 °F]
Frequency Range7 up to 1,000 Hz
WeightApprox. 190 g
Ingress ProtectionIP65
Ex-protection, IS ATEXII 2 G EEx ia IIC T4/T5/T6, BVS 03 ATEX E 156 CSA Ex ia IIC Class 1, Zone 0, AEx ia IIC
HousingAnodised aluminum (for dimensions please see drawings)
Technical Data OPTV
Ambient Temperature-20 °C up to +60 °C [-4 °F up to +140 °F]
Supply VoltageUB: 7 up to 30 V
Quiescent CurrentI R < 1,1 mA
OutputFrequency output, constant pulsetime 500 μsec
Electrical Data, AlternativelyVoltage outputs (3-wire connection)
a. Active output High level: Uhigh > UB – 0.6 V – [2.5 kΩ × Iout (mA)]
Low level: Ulow < 0.6 V + [1.3 kΩ × Iout (mA)]
b. Passive output
High level: Uhigh > U – [Iout (mA) × 1.3 kΩ] Low level: Ulow < 0.6 V + [1.3 kΩ × Iout (mA)]
U is the voltage applied at the output, max. 30 V
Current output (2-wire connection)
a. For UB < 9 V (NAMUR supply units)
High level: Ihigh > 2.2 mA
Low level: Ilow < 1.1 mA
b. For UB 7 up to 30 V
High level: Ihigh = [(UB – 0.6 V)/1.3 kΩ] + Ilow
Low level: Ilow = (UB – 4 V)/7.5 kΩ
Frequency Range3 up to 1,500 Hz according to flow meter
Electrical ConnectionTwo off 4-pin screw terminals for supply and output signals (see wiring schemes)
Ex Protection ATEXII2 G EEx ia IIC T6, DMT 03 ATEX E 089X
HousingGrey-coloured polycarbonate for DIN hat top rail mounting

Download Datasheet: FOP and OPTV Kem Kuppers Fibreoptical Amplifier and Lightpulse Receiver