Dinel CLM–36 Capacitive level meter

Dinel CLM–36 Capacitive level meters are designed for continuous level measurement of liquids, powders, and bulk-solid materials in vessels, tanks, sumps, containers, silos, etc. CLM consists of a stainless steel housing with an electronic module and the measuring electrode. The electronic part converts the capacity into the current signal (4 … 20 mA) or voltage signal (0 … 10 V). Sensitivity (SPAN) and initial capacity compensation (ZERO) can be fluently set.

Level meters are produced in the following performances: N – for non-explosive areas, NT – high temperature for non-explosive areas, Xi – Explosion-proof – intrinsically safe for hazardous (explosive) areas, and XiT – high-temperature conf. for explosive environments. CLM is offered in variants with various types of process connections (thread, Tri-clamp).

Dinel CLM–36 For continuous level measurement of liquid and bulk solid materials

  • Direct mounting into containers, silos, basins, vessels, reservoirs, etc.
  • Easy and quick connecting by a connector
  • Continuous adjustment of initial capacity
  • Current (4 … 20 mA) or voltage (0 … 10 V) output
  • Removable electronic module
  • The material of housing and rod electrodes from stainless steel
  • Xi, XiT versions for usage in explosive areas

Dinel CLM–36 Technical Data

Supply voltageCLM – 36N(T)–_ _–_–I9 … 36 V DC
CLM – 36N(T)–_ _–_–U16 … 36 V DC
Current output4 … 20 mA
Voltage output0 … 10 V *
Power consumption (off-load) CLM–36N(T)–_ _–_–U approx. 8mA
Sensitivity ranges20; 30; 50; 100; 150; 300; 500; 1000 pF
Initial capacity regulation ratiomin. 1:2
Nonlinearitymax. 1 %
Temperature errormax. 0,05% / K
Voltage error for current and voltage output max. 0,3 μA/V and 0,1 mV/V
Internal resistance / Electric strength (Electrode – Housing)1 MΩ / 250 V AC
Coupling capacity / Electric strength (Housing – Supply leads) 51 nF / 250 V AC
Protection class
standardIP67 (Housing), IP65 (Connector) IP67
Optional (Connector GAN-DADE 7A / DAEE 7A)
Maximal load (serial) resistance for current output (U = 24 V) Rmax= 750 Ω
Minimal load resistance for voltage output Rmin > 1 kΩ
Maximum tensile strength of the rope electrode 1400 kg
Recommended cablePVC 2×0,75 mm2 (3×0,5 mm2)
Weight (exclude electrode)
Version N, Xiapprox. 0,5 kg
Version NT, XiTapprox. 1 kg