Emerson Rosemount 3051CFP Coplanar™plat formenables integration of primary elements,manifolds,and remoteseal solutions, Best in Class performance with up to 0.05% high accuracy option, IEC 62591(WirelessHART®)Protocol enables cost effective installations
Maximize installation and application flexibility with the coplanar platform
- Improve reliability and performance with integrated DP Flow meters, DP Level solutions, and integral manifolds.
- Easy installation with all solutions fully assembled, leak-tested, and calibrated.
- Meet your application needs with an unsurpassed offering.
Proven best-in-class performance, reliability, and safety
- More than seven million installed
- Reference accuracy 0.04 percent of span
- Installed total performance of 0.14 percent of span
- 10-year stability of 0.2 percent of URL
- SIL2/3 certified (IEC 61508)
Emerson Rosemount 3051CFP Feature
- Local Operator Interface (LOI) offers easy to use configuration capabilities at the transmitter
- Protocols available include HART®4–20mA,FOUNDATION™Fieldbus,PROFIBUS®PA,HART1–5VdcLow Power
- Selectable HART Revision prepares your plant for the latest HART capabilities while ensuring seamless integration with today’s systems
- SIL2/3safety certification to IEC61508 is available with the full 4–20mA HART offering to simplify compliance
Another Article: |
This product data sheet covers HART, Wireless, FOUNDATION Fieldbus, and PROFIBUS PA Protocol sunless specified.Conformance to specification (±3s[sigma])Technology leadership, advanced manufacturing techniques, and statistical process control ensure specification conformance toat least ±3s.Reference accuracyStated reference accuracy equations include terminal based linearity, hysteresis, and repeatability.
For Wireless,FOUNDATION Fieldbus, and PROFIBUS PA devices, use calibrated range in place of span.
Models | Standard | High performance option, P8 | |
Rosemount 2051C | |||
Range 1 |
±0.10% of spanFor spans less than 15:1, accuracy =±æ0.025+0.005 —U—-R—L—–ö %ofspanè Spanø |
N/A |
N/A |
Ranges 2–4 |
±0.065% of spanFor spans less than 10:1, accuracy =±æ0.025+0.005 —U—-R—L—–ö %ofspanè Spanø |
Ranges 2–4 |
High accuracy option, P8±0.05% of spanFor spans less than 10:1(1), accuracy =±æ0.015+0.005 —U—–R—L— ö %ofspanè Spanø |
Range 5 |
±0.075% of spanFor spans less than 10:1, accuracy=±æ0.025+0.005 —U—–R—L— ö %ofspanè Spanø |
Range 5 |
High performance option, P8±0.065% of spanFor spans less than 10:1, accuracy=±æ0.015+0.005 —U—-R—L—- ö %ofspanè Spanø |
Rosemount 2051T, 2051G | |||
Ranges 1–4 |
±0.065% of spanFor spans less than 10:1, accuracy =±æ0.0075 —U—-R—L—–ö %ofspanè Spanø |
Ranges 1–4 |
High accuracy option, P8±0.05% of spanFor spans less than 10:1(1), accuracy =±æ0.0075 —U—-R—L—- ö %ofspanè Spanø |
Range 5(2) | ±0.075% of spanFor spans less than 10:1, accuracy =±æ0.0075 —U—-R—L—–ö %ofspanè Spanø | N/A | N/A |
Rosemount 2051L | |||
Ranges 2–4 | ±0.075% of spanFor spans less than 10:1, accuracy =±æ0.025+0.005 —U—–R—L— ö %ofspanè Spanø | N/A | N/A |
1. For protocol code F, accuracy specification is for spans less than 7:1. Not available with out put codeW.2. Rosemount 2051G is not available with Range5.