Description
Signet 2552 Metal Magmeter Flow Sensor from Georg Fischer features all-stainless steel construction. The PVDF nosepiece and FKM O-rings are the only other wetted materials. The 2552 installs quickly into standard 1¼ in. or 1½ in. pipe outlets, and is adjustable to fit pipes from DN50 to DN2550 (2 to 102 in.). Two sensor lengths allow maximum flexibility to accommodate a variety of hardware configurations, including ball valves for hot-tap installations.
When equipped with the frequency output, the 2552 is compatible with any externally powered Signet flow instrument, while the digital (S3L) output enables multi-channel compatibility with Signet 8900, 9900 or 9950 Multi-Parameter instruments. Select the blind 4 to 20 mA current output to interface directly with data loggers, PLCs or telemetry systems. Key features include Empty Pipe Detection, LED-assisted troubleshooting, and bi-directional span capability (in 4 to 20 mA models).
The Signet 3-0252 Configuration Tool is available to customize every performance feature in the 2552 so it can be adapted to the user’s application requirements.
Signet 2552 Metal Magmeter Features
- NIST test certificate included
- Award winning hot-tap magnetic flow sensor up to DN2550 (102 in.)
- Patented Magmeter technology*
- Operating range 0.05 to 10 m/s (0.15 to 33 ft/s)
- Reliable operation in harsh environments
- Repeatable: ±0.5% of reading @ 25 °C
- Three output options: 4 to 20 mA, Frequency/Digital (S3L)
- ISO or NPT Threads
Applications
- Municipal Water Distribution
- Process and Coolant Flow
- Chemical Processing
- Wastewater
- Mining Applications
- Water Process Flow
- HVAC
Signet 2552 Metal Magmeter Specifications
General | |||
Operating Range | Minimum | 0.05 m/s | 0.15 ft/s |
Maximum | 10 m/s | 33 ft/s | |
3 m/s | 10 ft/s | ||
Pipe Size Range | DN50 to DN2550 | 2 to 102 in. | |
Linearity | ± 1% reading plus 0.1% of full scale | ||
Repeatability | ±0.5% of reading @ 25 °C | ||
Accuracy | ±2% of measured value* | ||
*In reference conditions where the fluid is water at ambient temperature, the sensor is inserted at the correct depth and there is a fully developed flow profile which is in compliance with ISO 7145-1982 (BS 1042 section 2.2) | |||
Minimum Conductivity | 20 µs/cm | ||
Wetted Materials | |||
Body and Electrodes | 316L stainless steel | ||
Insulator | PVDF | ||
O-rings | FKM | ||
Cable | 4-cond + shield, PVC jacket (Fixed cable models) or Water-resistant rubber cable assembly with Turck® NEMA 6P connector | ||
Power Requirements | |||
4 to 20 mA | 24 VDC ±10%, regulated, 22.1 mA maximum | ||
Frequency | 5 to 24 VDC ±10%, regulated, 15 mA maximum | ||
Digital (S3L) | 5 to 6.5 VDC 15 mA maximum | ||
Reverse Polarity and Short Circuit Protected | |||
Cable Options | |||
Fixed Cable | 7.6 m | ||
Detachable water tight sensor cable with Turck® connector (sold separately) two lengths: 4 m (13 ft) or 6 m (19.5 ft) | |||
Electrical | |||
Current Output (4 to 20 mA) | Programmable and Reversible | ||
Loop Accuracy | 32 µA max. error (@ 25 °C @ 24 VDC) | ||
Temperature Drift | ±1 µA per °C max. | ||
Power Supply Rejection | ±1 µA per V | ||
Isolation | Low voltage < 48 VAC/DC from electrodes and auxiliary power | ||
Maximum Cable | 1000 ft | ||
Maximum Loop Resistance | 300 ? | ||
Error Condition | 22.1 mA | ||
Frequency Output | Compatible with | Signet 8900, 9900, 9900-1BC and 9950 | |
Maximum Pull-up Voltage | 30 VDC | ||
Short Circuit Protected | ?30 V @ 0 ? pull-up for one hour | ||
Reverse Polarity Protected | to -40 V for 1 hour | ||
Overvoltage Protected to +40 V for 1 hour | |||
Maximum Current Sink | 50 mA, current limited | ||
Maximum Cable | 1,000 ft | ||
Digital (S3L) Output | Compatible with | Signet 8900, 9900, 9950 and 0486 | |
Serial ASCII, TTL level 9600 bps | |||
Maximum Cable | Application dependent (See 8900 or 9900 manual) in non-icing conditions | ||
Operating Temperature | Ambient (non-icing conditions) | 5 °F to 158 °F | |
Media | 5 °F to 185 °F | ||
Max. Operating Pressure | 20.7 bar @ 25 °C | 300 psi @ 77 °F | |
Hot-Tap Installation Requirements | |||
Maximum Installation Pressure | 300 psi | ||
Maximum Installation Temp (Insertion/Removal) | 104 °F | ||
Do not use hot-tap installation where temperatures will exceed 40 °C or if hazardous liquids are present. | |||
Shipping Weights | |||
3-2552-2X-A-11/A-12 | 2.50 kg | 5.51 lb | |
3-2552-2X-B-11/B-12 | 2.30 kg | 5.07 lb | |
3-2552-3X-A-11/B-11/A- | 4.00 kg | 8.81 lb | |
12/B-12 | |||
Standards and Approvals | CE, FCC | ||
RoHS compliant, China RoHS | |||
NEMA 4 (IP65) | Fixed cable models | ||
NEMA 6P (IP68) | Submersible cable models only. Signet recommends maximum 3 m (10 ft) submersion depth for maximum 10 days continuous submersion. | ||
Manufactured under ISO 9001 for Quality and ISO 14001 for Environmental Management and OHSAS 18001 for Occupational Health and Safety |
Model 2552
Ordering Notes
- 1) Sensor insertion depth is the distance from the bottom of the sensor housing to the tip of the sensor.
- 2) Hot-Tap installations require a 1¼ in. or 1½ in. ball valve.
- 3) See Sensor Selection Guide on previous page to determine the sensor length required.
Accessories and Replacement Parts
- Application Tips
- Minimum process liquid conductivity requirement is 20 ?S/cm.
- 1½ x 1¼ inch and 2 x 1¼ inch (2552-1 and 2552-2 only) retrofit adapters are available for replacement installations of Signet
2550 and 2540 sensors
Download Datasheet: Signet 2552 Metal Magmeter Flow Sensor
Reference : gfps.com