Jain Technology Xonic 10G Ultrasonic Gas Flow Meter

Ultrasonic Gas Flow Meter Like Xonic-10G Ultrasonic Flowmeter uses Ultrasonic Transit-Time Technology, it shows superior performance than the conventional pressure gas flow meter. Depends on pipe size, it uses one path or three path ultrasonic sensor(s), and the temperature sensor is embedded for volume compensation.

Ultrasonic Gas Flow Meter Xonic 10G by Jain Technology

Xonic-10G Ultrasonic Flowmeter uses Ultrasonic Transit-Time Technology, it shows superior performance than the existing pressure GFM. Depends on pipe diameter size, it uses one path or three paths ultrasonic sensor(s), and the temperature sensor is embedded to give compensation volume. Xonic-10G is developed as the first ultrasonic type gas flow meter in Korea.

Read More : Flowma WUF 400 J Portable Ultrasonic Flow meter

Characteristic

  • 01 m/s Measuring low flow rates
  • Wide measuring range 200:1
  • No moving parts
  • pressure loss control
  • Easy installation and maintenance
  • 2 Cross paths measurement
  • Temperature sensor, and the volume compensation

Application

  • Natural Gas
  • Flare Gas
  • COG Gas
  • Bio Gas
  • Vapor Gas
  • Fuel Gas
  • Vent Gas

Field of Application

  • Natural Gas Flowmeter
  • AIR Supply Lines
  • Combustion Gas
  • Tunnel Air Flow Control

Ultrasonic Gas Flow Meter Xonic 10G Features

Outstanding Performance

Xonic-10G demonstrates higher and more accurate velocity measurement range compared to the existing mechanical. Direct Command Flow maintains 1% of accuracy, minimum versus maximum flow rates is 200 times over.

Other Articles : Jain Xonic 100P Portable Ultrasonic Flow Meter

Digital Signal Processing

To have accurate analysis of the ultrasonic signal, DSP advanced technique is used to calculate the time lag according to the flow velocity. In worst noise, it consecutively maintains high accuracy by detecting clear signal.

Self-Diagnostic /Test Function

In the field, flowmeter operational status could be checked through Xonic-10G graphic LCD panel. In particular, with a simple manipulation, the oscilloscope ultrasonic signal function makes it possible to determine the operational status gauge in the field.

Other Articles : Xonic 100L Jain Clamp On Ultrasonic Flow Meter

Ultrasonic Gas Flow Meter Xonic 10G Specifications

General Specification

Measurement method ultrasonic transit-time difference
Velocity Measurement -30 m/s ~ 30 m/sec
Minimum Velocity 0.01 m/s
Display Flow (Instant Flow, standard, mass), Total Flow, Velocity
Accuracy (Reading) 0.5%
Reproducibility 0.25%
Diagnostic Function the shape of the ultrasonic signal, value gain, ΔT, FFT
Measuring Gas Type natural gas, gas, AIR, combustion gas
Converter
Temperature -20 ~ +60℃
Explosion Proof IECEx Ex d II C
In / Output Relays Normally open
Analog Cut 4-20mA
Analog In 4-20mA
Communication RS-232C, RS-485 MobBus
Power 12~24VDC
Flange / Transducer
Flange Range 50 ~ 300mm flange type
Material Stainless 304
Temperature -20 ~ +80℃
Working Pressure 20 bar below
Temperature Sensor 500Ω 4 wire, -40 ~ +120℃

Download Catalog : Inline Gas Flowmeter (Xonic 10G)

Share