Technical Details

  • Accuracy:
    ± 2,5% of full scale
    ± 5% of full scale (OEM version)
  • Linearity: 1% of full scale
  • Medium temperature: -40…+70°C
  • Ambient temperature: -30…+60°C
  • Max. operating pressure:10 bar
  • Protection: IP 65

Kobold DPL Materials

  • Housing: polypropylene
  • Rotating vane: polypropylene
  • Axle/bearing: sapphire
  • Vane mount: polysulfone
  • Gasket: NBR, FPM or EPDM

Operating Principles

The medium flows through a specially shaped flow housing and causes a vane to rotate. This rotary motion is sensed by optoelectronics in a non-contacting manner, and converted to an asymmetric frequency signal or an analogue signal. A frequency divider with symmetrical output is available as an option. The frequency is proportional to the flow velocity. The vane is sapphire-supported: this ensures a high degree of linearity and long service life.

Kobold DPL Electronics

Frequency output (OEM without CE-Sign)

  • Power supply: 4.5 – 12 VDC
  • Supply current: typ. 7 mA
  • Signal amplitude high: approx. power supply
  • Signal amplitude low: ≤0.2 V
  • Transmitter cut-off voltage: 3 V max.
  • Transmitter supply current: 8 – 12 mA
  • Output loss: max. 2.5 mWatt
  • Electrical connection: solder pins
  • Pulse output: NPN, Open Collect., max.10 mA

Frequency output (option frequency divider)

  • Power supply: 24 VDC ±20%
  • Supply current: 40 – 50 mA
  • Signal amplitude high: approx. power supply
  • Signal amplitude low: ≤0.2 V
  • Output loss: max. 2.5 mWatt
  • Electrical connection: plug M12x1 (option: 2 m PVC cable)
  • Division ratio (option): 1…1⁄128 factory set
  • Pulse output: PNP, open collector, max. 20 mA

Analogue output (option plug-on display)

  • Power supply: 24 VDC ±20%
  • Output: 0-20 mA or 4-20 mA, 3-wire technology
  • Max. load: 500 Ω
  • Electrical connection: plug connector M12x1 or DIN 43 650
  • Option: plug-on display (with plug connector DIN 43 650 only)

Compact electronics

  • Display: 3-position LED
  • Analogue output: (0)4…20 mA adjustable, max. 500 Ω
  • Switching outputs: 1 (2) semiconductor PNP or NPN, factory set
  • Contact operation: programmable N/C/ N/O contact
  • Setting: via 2 buttons
  • Power supply: 24 VDC ±20%, approx. 100 mA, 3-wire technology
  • Electrical connection: plug connector M12x1

     Another Article:

Kobold DPL Rotating Vane Flowmeters
Pulse Output DPL-..F5

Measuring range: 0.025 – 0.5  … 1 – 25 l/min water

Connection: G ½ male thread or hose connector
Material: polypropylene
pmax10 bar
tmax: 70°C
Linearity: ±1 %
Pulse output, frequency divider

Kobold DPL Rotating Vane Flowmeters
Analogue Output DPL-..L3

 

Measuring range: 0.025 – 0.5  … 1 – 25 l/min water
Connection: G ½ male thread or hose connector
Material: polypropylene
pmax10 bar
tmax: 70°C
Linearity: ±1 %
Analogue output

Kobold DPL Rotating Vane Flowmeters
Analogue Output DPL-..L4 with AUF

Measuring range: 0.025 – 0.5  … 1 – 25 l/min water

Connection: G ½ male thread or hose connector
Material: polypropylene
pmax: 10 bar
tmax: 70°C
Linearity: ±1 %
Analogue output, digital indicator

 

Kobold DPL Rotating Vane Flowmeters
Compact Electronic DPL-..C3

Measuring range: 0.025 – 0.5  … 1 – 25 l/min water

Connection: G ½ male thread or hose connector
Material: polypropylene
pmax10 bar
tmax: 70°C
Linearity: ±1 %
Analogue output, contacts NPN / PNP, digital indicator

Kobold DPL Rotating Vane Flowmeters
Counter DPL with ZED

 

Measuring range: 0.025 – 0.5  … 1 – 25 l/min water
Connection: G ½ male thread or hose connector
Material: polypropylene
pmax10 bar
tmax: 70°C
Linearity: ±1 %
Analogue output, totalizer, contacts, digital indicator