Lorric FP-AS510 Paddlewheel Flow Meter

Overview

LORRIC is the Taiwanese manufacturer of industrial nozzles and flow meters established in 1991, and since then has dealt in independent research and development, design, production, marketing, and sales.

The Philosophy we believe as below makes us to design and manufacture best products and improved and grow up

We at LORRIC pride ourselves in creating industry-used high-grade nozzles through our meticulous techniques and exclusive knowledge. Through our craftsmen’s vast experience and diligence in understanding our customers’ requests, our products’ high quality ensures that even under the harshest of environments, they will perform as accurate as ever.

LORRIC takes to heart its clients’ demands for performance, and cautiously tackles every challenge presented. Taking inspiration from whales, who deep down in the wide blue ocean sing their songs to call their peers in an extraordinary frequency of 52 hertz, LORRIC too are looking for clients who embrace similar values, and like-minded global partners. Let us together become a community, and share with the world our values and uncompromising spirit.

LORRIC wishes to prove to the world that Taiwan also has the capability for the most exquisite and precise of industrial production. Our company’s founder henceforth prides himself in knowing that LORRIC today stands as a world leader in the manufacturing of nozzles and flowmeters, and as such is also able to place Taiwan as a shining radiant spot on the map.

Lorric FP-AS510 AxleSense paddlewheel flowmeter

The Patented AxleSense Technology

Patent received technology – LORRIC improved upon the conventional design of placing the magnet on top of the paddle, creating a unique patented “AxleSense paddle”. On top of that, LORRIC redesigned the flow measurement algorithm, thus introducing the new patented “AxleSense” technology, which allows for a substantial upgrade in the sensing capabilities of extremely small flow rates, as well as the immediate monitoring of any paddle abnormalities.

Patented product with a measuring range that doubles that of other brands, which allows for the detection of any disappearance of the paddle which tends to cause zero-flow problems, on top of large indicator lights and a large screen that allows for more convenient on-site supervision.

Lorric FP-AS510 Paddlewheel Flow Meter has a measuring range that doubles that of other brands, which allows for the detection of any disappearance of the paddle which tends to cause zero-flow problems, on top of large indicator lights and a large screen that allows for more convenient on-site supervision.

Inspected and proofed by SGS, RoHS compliant, the FP-AS510 has a measuring range that doubles that of other brands, which allows for the detection of any disappearance of the paddle which tends to cause zero-flow problems, on top of large indicator lights and a large screen that allows for more convenient on-site supervision.

Benefit

A wider flowrate detection range  (0.15 m/s~10m/s)

In traditional paddle wheel flowmeters, the sensing magnet is placed on top of the paddle, which means that during low liquid flow speed phases, flowrate detection has a large margin of error, even to the level of not being able to detect any flow at all. LORRIC’s paddlewheel flowmeter employs the patented AxleSense technology which shifts the direction of flowrate detection, which means that even under low flow speeds, any paddle movement will be accurately sensed, as well as maintaining a low margin of error for flowrate monitoring, which in turn provides the user with a more extensive application range.

An active smart mechanism for the detection of flow problems that arise from paddle disappearance

A flowmeter’s inability to detect flow may originate from problems in the pump, pipes, the equipment itself, or because of problems of crystallization, wear and tear or fracturing of the paddlewheel flowmeter that may cause the paddle to be damaged or fall off. LORRIC’s patented AxleSense technology actively detects any paddle abnormalities and offers clear information for the on-site manager to see, and will not simply display a passive “zero-flow” notice. Regarding industry 4.0 users, LORRIC’s paddlewheel flowmeter’s detailed information can be integrated with the factory’s management system, which helps on-site workers to solve any flow problems even faster.

Bidirectional flow detection

LORRIC’s patented AxleSense technology uses the paddle’s direction to detect the flow’s fundamentals, while at the same time supplying direct information about the flow direction inside the pipelines. This in conjunction with integration with the factory’s management system, makes on-site management more convenient.

Large green, orange and red alarm indicator lights

  • Large bright LED screen allows for data monitoring at any time from far away, which saves the need to constantly check the screen from up close.
  • Green, orange and red indicator lights: Red – Major abnormality; Green – Normal operation; Orange – Non-urgent data display. This system’s big advantage is that no matter how far the user stands from the screen, the changing indicator light’s color can clearly indicate the status of the equipment and whether any abnormality occurs.

Feature

  • LORRIC exclusive patent – The AxleSense Technology
  • Exclusive LCD/LED double screen design, double screen monitoring which makes work
    equivalent to 1+1>2
  • Green, yellow and red indicator lights: Red – Major abnormality; Green – Normal operation;
    Yellow – Non-urgent data display.
  • Daily Accumulation of positive/negative/net flow volume in the past 14 days
  • The screen can change direction according to the pipes’ alignment.
  • Bidirectional flow detectable

Application

  • PCB wet process
  • Panel industry
  • Semiconductor
  • Water treatment
  • Food Manufacturing
  • Dyeing
  • Chemical industry
  • Wastewater without large particle

Lorric FP-AS510 Paddlewheel Flow Meter Specification

Installation methodin-line (Pipe segment)
Fluid in pipes temperatureUnder 0~50 °C (32~122°F)
Device working environment temperature-25~70°C (-13~158°F)
Tee pipe connectorPVC Gluing adaptors(ASTM, JIS, DIN), PVC internal and external thread Connector (BSPT and NPT)
Paddle materialPVDF with embedded magnet + ceramic bearing and shaft
Tee pipe materialUPVC
Power supplyDC 12V to 36V 100mA
Response time< 0.5 second
Waterproof levelIP65 *
Applicable fluid maximum dynamic viscosity300cSt
Applicable fluidClear, oil or chemicals with fewer impurities (<1%)
Linearity± 0.5 % FS (>0.3m/s)
Reproducibility± 0.4 %
OR tolerance± 2.5 % OR
Measuring principlePaddle Wheel
Flow rate range± 0.3~10m/s Can extend to ± 0.15m ~ 10m/s *
Tee pipe diameter (mm)DN20-50 (¾” to 2″)
Transient dataInstantaneous flow and flow rate
Cumulative dataPositive and negative net flow accumulation, past 14 days and long-time accumulative net flow

User Interface

LanguageEnglish, Traditional Chinese, Simplified Chinese (Others customizable)
UnitMetric:Litre, cubic meters, meters
Time:second, minute, hour, day
Imperial:foot, Cubic foot, Uk gallon, US gallon
DisplayDouble screen display: Large 5-Digit LED,
16×3 3-Color Backlit LCD display
Display digitsLED 5 Digits
LCD 10 Digits
Operation button4 Key touch buttons
Wired communicationAnalog output 4-20mA ( External Power Supply Required)
Modbus RTU RS485 Two-line
OCT switch signal(ship with 2-meter cable)
Calendar function batteryCR2032

Datasheet: lorric_catalogue_FP-AS510