Rheonik RHM 015 Coriolis Mass Flow Sensor

Nominal Flow (Qₙₒₘ)*0.6 kg/min (1.32 lb/min)
Maximum Flow (Qₘₐₓ)*1.2 kg/min (2.65 lb/min)
Typical Minimum Flow (Qₘᵢₙ)*0.002 kg/min (0.004 lb/min)
Serial Tube / Single PathFlow rates Qₘₐₓ, Qₙₒₘ and Qₘᵢₙ for “serial” sensors will be 50 % of the above-listed parallel/dual path version.
Operating TemperatureFluid temperature range options cover from -196 °C to +210 °C (-320 °F to +410 °F)
For integral transmitter versions please refer to the transmitter datasheet
Ambient Temperature-50 °C to +80 °C (-60 °F to +180 °F).  High-temperature version for oven installation up to +210 °C (+410 °F) available
Pressure Ratings1481 bar (21480 psi) – dependent upon material
Electrical Connection SensorM20 x 1.5 standard cable entry for JM, SM terminal box versions
w/o Integral TransmitterOptional entries available : ½” NPT or M25 x 1.5 (only for SM) or ¾” NPT (only for SM)
M16 x 1.5 standard cable entry for PM terminal box version
Max. cable length to remote RHE transmitter 100 m/330 ft.
Sensor Enclosure MaterialsStainless steel 304 (standard), SS 316 (optional)
Coated aluminum terminal box, SS 316 terminal box (optional)
Enclosure TypeProtection class IP 66, NEMA 4 (standard), IP 66/67, NEMA 4X (optional)
Wetted MaterialsFlow tubes SS 316 L, SuperDuplex, Sandvik HP160®, or Alloy C22
Manifolds SS 316 L, seals FKM, FFKM, FVMQ, EPDM
Standard flanges SS 316 Ti, other connections SS 316 L
Additional/customer-specific materials available upon request
Process ConnectionsNearly any – the Rheonik AnyPipeFit Commitment.  Consult the factory for types/sizes not listed in this data sheet on the Mechanical Construction pages
Pressure Rating CompliancePED 2014/68/EU Article 4, Section 3 (SEP)
Certifications and ApprovalsATEX / IECEx Approvals Zone 0, 1, 2 (see datasheet)
North American Approvals Cl. I, Div. 1, 2, Gr. A, B, C, D, Zone 0, 1, 2 (see datasheet)
American Bureau of Shipping (ABS)
Testing and InspectionAll sensors are hydro-tested, calibrated, and supplied with a traceable calibration certificate. Customized calibration and testing services are available
Project Documentation and QA, ServicesRheonik offers a full set of services for large and complex engineering projects.
Typical services offered are, but are not limited to:
Certificates of origin and conformity, mill certificates
Data books including WPAR, WQS, NDT, test & quality plans, functional testing, calibration procedures, customized packing, factory acceptance, etc.
Painting to project specification
Start-up and commissioning services on/offshore
OptionsCustomization services for machine integration. Consult factory
author

Rudy Wiratama

rudywinoto.com/wmablog.com/flowmasonic.com

Similar Posts

Discover more from Indonesia Industrial Parts

Subscribe now to keep reading and get access to the full archive.