J. Schneider C-TEC 2410 5.8kJ

Description

J. Schneider C-TEC 2410 5.8kJ Capacitor buffered Power Supply, The DC UPS of the CTEC series has inside of the housing ultracaps as energy storage. In mains operation, the ultracaps will be charged by an external controlled DC power supply. In the event of interruption of DC power supply, the energy of the ultracaps will be released in a controlled way. The load will be fed until the C-TEC is discharged.

The buffer time depends on the output current and the energy of the ultracaps.

The C-TEC 2410 is characterized by the following properties:

  • Maintenance-free due to durable ultracaps
  • Micro-controller supported charging and discharging of the ultracaps
  • Operation monitoring and charge status monitoring by LEDs
  • Fast charging by active current charging control
  • IPC management by time triggered and output current triggered shutdown function
  • Numerous customer-specific parametrization settings by USB interface

J. Schneider C-TEC 2410 5.8kJ Technical Data

Input

Nominal input voltage*

12 V DC / 24 V DC (SELV / PELV)

Input voltage range in charge mode

Nominal input voltage 12 V DC (decoupled / non-decoupled)

Nominal input voltage 24 V DC (decoupled / non-decoupled)

11.9…17.4 V DC ±0 % / 11.4…17.4 V DC ±0 %
23.9…27 V DC ±0 % / 23.4…27 V DC ±0 %

Nominal input current

10 A

@ (Ue = 24.0 V DC, Ua = 23.2 V DC, Ia = 9.9 A

Inrush current

≤ 35 A / 2 ms

Charging current

Max. 7 A; active charging current control

Nominal input power

240 W
@ (Ue = 24.0 V DC, Ua = 23.2 V DC, Ia = 10 A)

Output

Nominal output voltage

12 V DC / 24 V DC

Nominal output voltage in buffer mode (system voltage)**

Nominal input voltage 12 V DC

Nominal input voltage 24 V DC

11.2 V DC ±4 %
23.2 V DC ±2 %

Nominal output current

10 A

Current limitation in discharge operation

11.25 A ±0.75 A

Limiting current monitoring in discharge operation
by switching-off

10.3 A ±0,1 A after 1.5 s

Energy capacity (typical)

NCPA0606G01

5,8 kJ (kWs) @ (Ua = 23.2 V DC, Ia = 2 A)

Efficiency

95,1 %
@ (Ue = 24.0 V DC, Ua = 23.2 V DC, Ia = 10 A)

Internal consumption in buffer mode

1.7 W

Short-circuit resistance

Mains operation

Buffer mode

Conditional short-circuit proof
Short-circuit proof

Fuse

Fuse output circuit

External

General

Protection class of the housing

IP20

Overvoltage category

II

Pollution degree

2

Dimensions (H x W x D)

6.78 in x 4.55 in x 5.65 in

(172 mm x 116 mm x 143 mm)

Weight

3.97 lbs 1.8 kg)

Operating temperature / storage temperature

Operating temperature UL tested

-40 °F(-40 °C)…140 °F (+60 °C)

50 °F (+10 °C)…140 °F (+60 °C)

Relative humidity

≤95 % non-condensing

Max. height above sea level (without power reduction)

6561.1 ft (2000 m)