Eltra CHS 580A Carbon Sulfur Analyzer

Eltra CHS 580A Carbon Sulfur Analyzer is the ideal analyzer for the simultaneous determination of carbon, hydrogen and sulfur in organic samples. ELTRA’s 580A analyzers (A = Autoloader) are equipped with an automatic sample loader, allowing for analysis of large numbers of samples without operator intervention.

The sample loader is available in two versions to accommodate 36 or 130 crucibles. The CHS-580A is based on the technology of the CHS-580 analyzer and features a vertical resistance furnace with ceramic tube. The temperature can be set in steps of 1 °C to a maximum of 1,550 °C.

Thanks to sample weights of up to 500 mg and more even in-homogeneous materials can be reliably analyzed. The analyzer can be equipped with up to three independent infrared cells according to the user’s requirements, allowing for a great variety of applications.

Eltra CHS 580A Carbon Sulfur Analyzer Advantages

  • Simultaneous carbon, sulfur and hydrogen determination with minimal sample preparation
  • Wide range of organic materials can be analyzed
  • Rapid, precise, accurate and reliable element determination
  • Resistance furnace can be set up to 1550 °c in steps of 1 °c
  • Customized infrared cells provide wide, dynamic measuring range
  • Due to gold ir path, increased cell live time for analysis of halogen or acid containing samples
  • Powerful software (multilingual, customized display, export of results)
  • Single and multi-point calibration
  • Low maintenance
  • Robust design allows usage in production control and laboratory

Application

Coal, Coke, Oil, Plant Materials, Rubber, Soot, Tobacco, Waste, etc.

Eltra CHS 580A Carbon Sulfur Analyzer Specification

Measured elementscarbon, hydrogen, sulfur
Samplesorganic
Furnace alignmentvertical
Sample carrierceramic crucibles
Field of applicationagriculture, biology, chemistry / plastics, coal / power plant, construction materials, environment / recycling, medicine / pharmaceuticals
Furnaceresistance furnace (ceramic tube), adjustable up to 1550 °C (steps of 1 °C)
Detection methodsolid state infrared absorption
Number of IR cells01-Mar
Material of IR pathgold
Typical analysis time60 – 180 s
Chemicals requiredmagnesium perchlorate, sodium hydroxide
Gas requiredoxygen 99.5 % pure (2 – 4 bar / 30 -60 psi) compressed air (4 – 6 bar / 60 – 90 psi)
Power requirements230 V, 50/60 Hz max. heat up current 2000 W
Dimensions (W x H x D)55 x 100 x 60 cm 85 x 35 x 45 cm (Autoloader for 130 crucibles)
Weight~ 90 kg (analyzer) ~ 15 kg (Autoloader for 130 crucibles)
Required equipmentbalance (resolution 0.0001g), monitor, PC
Required accessoriesAutoloader (for 36 or 130 crucibles)
Optional accessoriesTIC module, voltage stabilizer 5 KVA

Download Data Sheet: Carbon / Sulfur / Hydrogen Analyzer CHS-580A

Ref: eltra.com

Other Article:

Similar Posts

Discover more from Indonesia Industrial Parts

Subscribe now to keep reading and get access to the full archive.

Continue reading