Bamo RTM Continuous Level Transmitter

Bamo RTM Continuous Level Transmitter

Bamo RTM Continuous Level Transmitter consists of a Reed chain (REED contacts connected by resistors) switching when magnetic float passes in front.

The resulting resistor value is directly in correspondence with the level. The necessary magnetic field is created by the MNR 6/7, MAGTOP floats or SFA counterweight. The T2F transmitter in the head converts the resitor value into a 4-20 mA signal. Manufactured according to your application; Installation and commissioning are simplified on site (factory calibration). Measurement display: The RTM may be connected to a BAMOWIZ or to an ITU unit.

Bamo RTM Continuous Level Transmitter Features

  • Output signal: or 4-20 mA or resistor
  • Customized models
  • Direct mounting on top of a tank
  • Direct mounting on MAGTOP and SFA series

Application

Continuous level measurement on containers

Another Article:

Bamo RTM Continuous Level Transmitter Specification

Measuring height  From 250 mm up to 2,000 mm
Temperature  PVC-U: 0 … +50 °C; PPH: 5 … +80 °C
PVDF: 0 … +100 °C; AISI 316L: -10 … +110 °C
Pressure 1 bar max. at 20 °C for plastic versions 20 bar max. at 20 °C for AISI 316L version

Materials:

Stem and fitting PVC, PP, PVDF, or AISI 316L
Float PP, PVDF, or AISI 316L
Head housing PBT for plastic versions, IP65 Aluminum for AISI 316L version, IP65

Output signal:

Resistor output 2- from * xΩ to 10 kΩ
wire transmitter  4-20 mA; Power supply: 13 … 30 V DC
Accuracy By steps of 10 mm (resolution)

Download Data Sheet: Continuous Level Transmitter RTM

Ref: bamo.eu