Kobold DSV Float Flow Meter and Switches

Kobold DSV Float Flow Meter and Switches are based on the principle of the well-known float-type flowmeters except for the conventional tapering measuring tube.

These patented instruments are provided instead with a cylindrical flow tube with conical slots around the periphery. This eliminates the usual problems of guiding the cylindrical float within a tapering measuring glass. The novel design including the provision of an appropriately dimensioned annular gap of constant width between the float and the flow tube has enabled the sensitivity to dirt to be considerably reduced.

The float contains a permanent magnet which actuates a bistable reed contact external to the measuring tube, that is, the flowing medium is hermetically separated from the electrical contact. In addition it is embedded in a height adjustable switch housing thus ensuring that the contact is protected even in an aggressive atmosphere.

As the medium enters the instrument the float rises. Once its magnetic field reaches the contact tips of the reed switch the contact connects. As the flow increases the float rises further until it reaches its stop. This prevents the float from going beyond the contact range of the magnetic operating tube, that is, the contact remains connected thus ensuring bistable switching. The top edge of the float serves to indicate the flow on the measuring glass in l/min.

Kobold DSV Float Flow Meter and Switches DSV-1

Float-type Flowmeters Switches DSV-1
Float-type Flowmeters Switches DSV-1

Measuring range: 0.25 – 1.25 … 10 – 130 l/min water
Connection: G ¼ … G 1¼ , ¼ … 1¼” NPT female thread
Material: brass, stainless steel
pmax: 10 bar
tmax: 100°C
Accuracy: ±4 % of full scale

Kobold DSV Float Flow Meter and Switches DSV-3

Measuring range: 0.25 – 1.25 … 10 – 130 l/min water
Connection: G ¼ … G 1¼ , ¼ … 1¼” NPT female thread
Material: brass, stainless steel
pmax: 10 bar
tmax: 100°C
Accuracy: ±4 % of full scale
2 reed contacts

Kobold DSV Float Flow Meter and Switches Features

Applications

  • Machine tools
  • Glass-melting tanks
  • Cooling circuits
  • Welding machines
  • Induction furnaces
  • Pumps
  • Prevention of low water levels

Specifications

Technical Details

  • Housing: aluminium anodised (not media-contacted)
  • Connections:
    DSV-x1..: brass Ms 58, nickel-plated
    DSV-x2..: stainless steel 1.4301
  • Float: see order details
  • Nozzle:
    DSV-x1..: brass Ms 58, nickel-plated
    DSV-x2..: stainless steel 1.3955
  • Measuring glass: borosilicate glass
  • Seals:
    DSV-x1..: NBR
    DSV-x2..: FPM
  • Max. temperature: 100°C (metal float)
    70°C (PP or PVDF float)
  • Max. pressure: 10 bar
  • Accuracy: ±4% of full scale
  • Installation position: vertical, flow in the upward direction

Download Datasheet: Kobold Float-type Flowmeters/Switches

Reference: kobold.com

Another Article:

Similar Posts

Discover more from Indonesia Industrial Parts

Subscribe now to keep reading and get access to the full archive.

Continue reading