Bamo Metallic CDV Flow Controllers and Indicators

Bamo Metallic CDV Flow Controllers and Indicators is used to monitor and visualize the flow-rate of a fluid free of suspended particles.

Bamo Metallic CDV Flow Controllers and Indicators Features:

  • Operates in all positions
  • Flow indicators, plus 1 flow contact
  • Versions: Stainless steel or brass
  • Pressure max. 16 bar
  • Flow ranges from 0.005 up to 150 l/min

Operation:

The fluid drives a magnetic orifice plate inside the cylindrical measuring tube. A spring balances its movement and allows to operate in all positions. The upper edge of the diver corresponds to the flow-rate on the graduated scale (in ml/min or l/min). A Reed contact, N.O. with no flow, is adjustable all along the scale, its status changes with the passage of the plate.

With these equipment, the CDV operates independently of the pressure, even in low flow rates.

Application:

Control and indication of flow-rate in cooling, high pressure pipings, dry-run pump prevention, etc.

Bamo Metallic CDV Flow Controllers and Indicators Specification:

Pressure limits16 bar for fittings ¼” & ½”; 10 bar for fittings 1”
Temperature-20 … +100 °C
Measuring scale unitl/min of water at 20 °C
Accuracy±10 % F.S.
Pressure drop0.02 … 0.4 bar (BSP 1”)
0.2 … 0.3 bar (BSP ½”)
0.2 … 0.2 bar (BSP ¼”)
SwitchN.O. without flow
HysteresisAbout 1.5 mm
ConnectionDIN 43650 plug-in socket
IP 65
Brass versionAnodized aluminum
Body
Fittings & orifice plateNickel plated brass
SpringAISI 316 Ti (1.4571)
SealsNBR
MagnetFerrite
Glass tubeGlass DURAN® 50
AISI versionAnodized aluminum
Body
Fittings, orifice plateAISI 316 Ti (1.4571)
SpringAISI 316 Ti (1.4571)
SealsFPM
MagnetFerrite
Glass tubeGlass DURAN® 50