Flocorp UltraFlo™ UFD3 Ultrasonic Portable Flow Meter

Flocorp UltraFlo™ UFD3 is a fixed or portable, clamp-on flow meter that is easy to install, accurate, and simple to use. The UltraFlo™ UFD3 is equipped with intelligent software to ensure high accuracy and low-velocity response. The flow meter has the ability to be a fixed unit or a portable unit.

The UltraFlo™ UFD3 ultrasonic flow meter is widely used in applications such as oil and gas, water treatment, pure water, chemical, and much more.

Flocorp UltraFlo™ UFD3 Features and Benefits

  • Backlit bright LCD display
  • RS232/RS485 or Modbus communication
  • Portable or Fixed unit
  • Highly accurate and easy to install
  • Clamps onto the pipe, requires no need to cut pipe
  • 5-year warranty

Specifications

PERFORMANCE
FLOW RANGE±0.09ft/s ~ ±40ft/s (±0.03m/s ~ ±12m/s)
ACCURACY±0.5% of reading (for ±1.5ft/s~±40ft/s)
REPEATABILITY0.15% of measured value
LINEARITY±0.5%
PIPE SIZE1” to 200” (25mm to 5000mm). Pipe size under 1” is an option
FUNCTION
OUTPUTSAnalog output: 4~20mA, max load 750Ù.
Pulse output: 0~9999Hz, OCT, (min. and max. frequency is adjustable) Relay output: SPST, max 1Hz,(1A@125VAC or 2A@30VDC)
COMMUNICATIONRS232 & RS485
MEMORYTF card (Max 4G)
POWER SUPPLY90 to 245 VAC, 48 to 63 Hz. Or 10 to 36VDC
DISPLAY240*128 back lit LCD
Transmitter: -40º~140º (-40º~60º)
TEMPERATURETransducer:-40º~176º (-40º~80º, standard)
HUMIDITYUp to 99% RH, non-condensing
PHYSICAL
TRANSMITTERIP65
TRANSDUCERIP68
Encapsulated design
Double-shielded transducer cable Standard/maximum cable length: 30ft/900ft(9m/274m)
Specifications are subject to change without notice.

 

 

PERFORMANCE

 

TEMPERATURE

Transmitter: -40º~140º (-40º~60º)

Transducer:-40º~176º (-40º~80º, standard)

 

FLOW RANGE

±0.09ft/s ~ ±40ft/s (±0.03m/s ~ ±12m/s)
 

HUMIDITY

 

Up to 99% RH, non-condensing

 

ACCURACY

±0.5% of reading (for ±1.5ft/s~±40ft/s)
 

PHYSICAL

REPEATABILITY0.15% of measured value
TRANSMITTERIP65
LINEARITY±0.5%
 

 

 

TRANSDUCER

IP68

Encapsulated design

Double-shielded transducer cable Standard/maximum cable length: 30ft/900ft(9m/274m)

 

PIPE SIZE

1” to 200” (25mm to 5000mm). Pipe size under 1” is an option
FUNCTION
 

 

 

OUTPUTS

Analog output: 4~20mA, max load 750Ù.

Pulse output: 0~9999Hz, OCT, (min. and max. frequency is adjustable) Relay output: SPST, max 1Hz,(1A@125VAC or 2A@30VDC)

 

Specifications are subject to change without notice.

COMMUNICATIONRS232 & RS485
MEMORYTF card (Max 4G)
 

POWER SUPPLY

90 to 245 VAC, 48 to 63 Hz. Or 10 to 36VDC
DISPLAY240*128 back lit LCD

Download Datasheet: UltraFlo™ UFD3, Flocorp-Ultrasonic Clamp-On Flow Meter

Ref: Flo-corp.com

Another Article:

Similar Posts

Discover more from Indonesia Industrial Parts

Subscribe now to keep reading and get access to the full archive.

Continue reading