TE KPSI 320 Submersible Level Transducer

TE KPSI 320 Submersible Level Transducer is a submersible hydrostatic level transducer specifically designed for small bore applications and to meet the rigorous environments encountered in groundwater level meter. This transducer provides repeatable, precision depth measurements under most adverse conditions.

Every KPSI Transducer utilizes a highly accurate pressure sensor assembly specifically designed for hostile fluids and gases. The assembly is integrated with supporting electronics in a durable waterproof housing constructed of 316 stainless steel or titanium.

he attached electrical cable is custom manufactured and includes para-aramid synthetic fiber members to prevent errors due to cable elongation and a unique water block feature that self-seals in the event of accidental cuts to the cable. Each vented reference transducer is shipped with our Superdry Vent Filter that prevents moisture from entering the vent tube for at least one year without maintenance, even in the most humid environments.

TE KPSI 320 Submersible Level Transducer

Features

  • Submersible level transducer
  • Small-bore, 0.75” diameter
  • ±0.25% FSO static accuracy
  • Custom polyurethane or ETFE cable lengths
  • Welded 316SS or titanium body
  • Custom level ranges up to 700 ft. (210 m) H2O
  • Multiple analog outputs
  • Ported nose cap
  • Optional lifetime lightning protection
  • Long-life vent filter or aneroid bellows
  • Available molded cable seal

Applications

  • Surface water monitoring
  • Well monitoring
  • Groundwater monitoring
  • Pump control
  • Slug tests
  • Level control
  • Ballast tank control

TE KPSI 320 Submersible Level Transducer

Specification

ParameterComment
Level Ranges
Full-scale level ranges
(Intermediate level ranges are available)
5 thru 700 ft. H2O, (1.5 thru 210 m H2O)Vented gage reference
10 thru 700 ft. H2O, (3 thru 210 m H2O)Sealed gage reference
35 thru 700 ft. H2O, (10 thru 210 m H2O)Absolute gage reference
Proof pressure1.5 x FS
Burst pressure2.0 x FS
Static Performance
Static accuracy
(Combined effects of non-linearity, hysteresis
and repeatability, best fit straight-line method)
±0.25% FSOBFSL method
Resolution+0.0001% FS
Electrical
Excitation9-28 V – VDC output
9-28 V – mA output
15-28 V – VDC output
10-28 V – VDC output
0-5 V, 0-2.5 V, 0-4 V
4-20
0-10 V
1.5-7.5 V
Input current20 mA max., 3.5 mA max.For mA output, for VDC output
Output4-20 mA, 0-5 VDC, 0-2.5 VDC,
0-4 VDC, 0-10 VDC, 1.5-7.5 VDC
For ranges < 5 ft. (1.5 m) H2O,
only 4-20 mA output is available
Zero offset±0.25 mA for mA output
< 0.25 VDC for VDC output
Output impedanceSee loop diagram at Datasheet for mA output
20 ohm for VDC output
Insulation resistance100 megaohm at 50 VDC
Circuit protectionPolarity, surge/shorted output
Physical
Approximate weight0.47 lbs. (224 g) transducer
0.05 lbs./ft. (79 g/m) cable
Cable jacket materialPolyurethane (standard),
ETFE (optional)
Cable pull strength200 lbs. (90 kg)Polyurethane
Cable number of conductors4
Cable conductor size22 AWG
Cable sealMolded polyurethane
FKM Gland
For polyurethane cable
For ETFE cable

Download Datasheet: TE Connectivity KPSI 320 Submersible Level Transducer

Another Article:

author

Rudy Wiratama

rudywinoto.com/wmablog.com/flowmasonic.com

Similar Posts

Discover more from Indonesia Industrial Parts

Subscribe now to keep reading and get access to the full archive.

Continue reading