Chalwyn MPX Series Shut Down Valves

DESCRIPTION

Chalwyn MPX CE236 Pressure to Close Butterfly Valve with Manual Close is designed to mechanically latch in the open position for the diesel engine to run. In the event of an engine over speed condition, direct pneumatic pressure is applied to release the latching mechanism and allow positive spring action to close the valve. The valve is designed to be opened manually. The valve includes options for a micro switch position indication, local stop button close, pushbutton manual cable close, and pull “T” handle manual cable close.

A range of 3”, 5” and 8” bore slim butterfly air intake shut down valves with air pressure actuated shut down combined with manual reset and the optional addition of manual shut down. Suitable for both hazardous and non-hazardous area applications. MPX valves are available in basic flange mounted form or fitted with hose adaptors. Valve body and disc are manufactured in corrosion resistant hard anodized aluminum with PTFE coating. The valve spindle and mechanism is made from stainless steel.

MPX CE236 Pressure to Close Butterfly Valve Features

  • For use with automatic or manual electric systems when electric-to-air valve is incorporated (see accessory SVA-200)
  • Suitable for hazardous and non-hazardous area applications
  • Pressure to close valve is between 29 to 145 psi (2 to 10 bar)
  • Local and cable operated manual close options
  • Slim-fit 3”, 5”, and 8” (76mm, 127mm, and 203mm) valve body
  • Basic flange mount with hose adaptors available (1½” to 8” | 38 to 203mm)
  • Valve bodies and discs are PTFE coated hard anodized aluminum
  • Shaft and mechanisms are stainless steel

Applications

  • Drilling rigs (onshore & offshore)
  • Drilling support equipment
  • Well servicing equipment
  • Refinery support equipment
  • Mining equipment
  • Road vehicles with air brakes
  • Large cranes with pneumatic systems

Chalwyn MPX CE236 Pressure to Close Butterfly Valve Specifications

Pressure to close: Min to Max29 psi to 145 psi2 bar to 10 bar
Actuation options:Microswitch Position Indication (3” and 5” only)
Local Manual Stop Button
Remote Pushbutton Cable Close (1m to 3m available)
Remote Pull “T” Handle Cable Close (1m to 3m available)
Valve body size:3” (76 mm)5” (127 mm)8” (203 mm)
Hose adapter size:1½”–4”
(38-102 mm)
3½”-6”
(89-152 mm)
7”-8”
(178-203 mm)

Chalwyn MPX CE236 Pressure to Close Butterfly Valve Operation

MPX Pressure to Close Valve

The Chalwyn MPX Pressure to Close Butterfly Valve with Manual Close is designed to mechanically latch in the open position for the diesel engine to run. In the event of an engine overspeed condition, direct pressure from the engine pneumatic or hydraulic control system is applied to release the latching mechanism. The positive spring action in the MPX valve will close the valve to shut down the engine.

The valve is designed to be opened manually using a reset lever on the top of the valve. The valve should be positioned where the reset is easily and safely accessible.

The basic MPX Valve is available with the options for a microswitch position indication. The microswitch position indication is not available on models with manual close.

Manual Close Options

The MPX Valve has 3 options to allow an operator to manually close the valve: local stop button, remote pushbutton manual cable, and remote “T” pull handle manual cable.

When using the local stop button option the valve, as mentioned in the prior paragraph, should be located where both the reset lever and stop button will be easily and safely accessible. For types with a remote manual stop, position the valve and select the cable length to give a reasonably straight cable run between the MPX valve and the proposed stop button or pull “T” handle position. Cables are available in lengths of 1.0, 1.5, 2.0 and 3.0 meters.

SELECTION

Determine the size and position of the MPX valve to be installed. Within the various constraints imposed in the application, the valve should be as generously sized as possible. Check that the valve can be positioned such that the reset lever and, where applicable, the stop button will be easily and safely accessible. For types with a remote manual stop, position the valve and select the cable length to give a reasonably straight cable run between the MPX valve and the proposed stop button position.

Air Pressure

A clean, dry air supply is required. An air pressure of approximately 2 bar is required to close the valve. Maximum air pressure must not exceed 10 bar.

OPERATION

Prior to starting the diesel engine the MPX valve must be latched in the open position by rotating the reset lever clockwise as far as possible. Once latched, the reset lever and valve will remain in the latched open position until released by application of air pressure or by operating the stop button.

After an emergency shut down by air pressure or by operating the stop button, the MPX valve must always be reset before re-starting the engine. After a normal (diesel fuel only) shut down, the MPX valve will not require reset.