Advanced Sensors SA-100P(2)/1000P(2) In-line Oil In Water Analyzer

Advanced Sensors In-line Oil The SA-100P and the SA-100P2 are respectively single and dual in-line probe Oil in Water analyzers suitable for non-hazardous areas; they both use fluorescence to provide continuous accurate measurements of oil concentrations in water.

The additional probe on the SA-100P2 allows the monitoring of two process points simultaneously with dual readings displayed on the analyzer. Reliable real-time data enables operators to take accurate measurements and to improve efficiency enabling cost reductions. The SA Series is ideally suited for refineries, and marine, industrial, and general waste-water monitoring. In addition to the standard probe features, the 1000 models offer spectral analysis.

Advanced Sensors In-line Oil Features

  • Adaptive ultrasonic cleaning.
  • Laser-Induced Fluorescence (LIF).
  • Remote management and diagnostics.
  • Easy to install.
  • Spectrometer (with SA-100P model)
  • Dual probe (with SA-100P2/ 1000P2)
  • For the option of hot insertion/ extraction, an extraction tool, and gearbox are recommended for pressures in the range of 3-5 bar. For pressures above 6 bar a gearbox is essential for hot insertion/ extraction.
  • Digital input and output.

Advanced Sensors In-line Oil Benefits

  • No user required maintenance.
  • Consistent accurate performance.
  • No sample conditioning system is required. Inserted directly in-process pipe.
  • Accurate OIW measurements over the laser lifetime of 18 months. No recalibration is required and no degradation of signal over the period of 18 months.
  • During process shutdown, the analyzer can be turned to standby mode through remote digital input. All signals are accessible remotely through Modbus/ Ethernet connectivity.
  • The spectrum of light wavelength is monitored and helps to find any process surge due to changes in process/ chemical addition. Oil-type switching is also feasible.
  • Simultaneous display of two-stream measurements in one device. Effective means of monitoring the performance of separation equipment both inlet and outlet.
  • With a double block and bleed valve, the probe can be inserted/ removed without the process shutting down.

Specifications

Measurement Performance

  • Measurement principle: Laser-Induced Fluorescence (LIF)
  • Cleaning: Ultrasonic (automatic)
  • Range: 0-20,000 ppm*
  • Repeatability: ±1% of measurement range
  • Accuracy: ±1% of full-scale range**
  • Response time: 1 Second, continuous results

Operating Conditions

  • Process temperature: Up to 200°C
  • Process pressure (MAWP): Up to 100 barg
  • Advanced Sensors In-line Oil Process flow: Nominal 10 m/s
  • Operational ambient temperature: -20°C to +55°C

Spectrometer Specifications (1000 models only)

  • Measurement wavelength range: 400-1,100 nm
  • Advanced Sensors In-line Oil Resolution: 0.5 nm

Utilities

  • Power supply: 110 or 230 VAC (Pre-configured)
  • Power frequency: 50 or 60 Hz
  • Power consumption: 60 W normal, 300 W peak

Certification

  • Ingress Protection Probe: IP66 (except IP68 for wetted portion)
  • Ingress Protection Enclosure: IP66 / NEMA 4X
  • CE Compliant:  CE
  • Analyzer: IMO MEPC-107 (49), ABS Type Approval

Weight & Dimensions (for shipping)

  • Weight (including stand): Sidestream or single probe 100kg, Dual probe 120kg
  • Dimensions: L 92 cm x W 83 cm x H 148 cm (except 980 mm probes);L 92 cm x W 83 cm x H 176 cm (with 980 mm probes)

Communications

  • 4-20 mA (1): Passive, Configurable for measurement readings/temperature
  • Advanced Sensors In-line Oil Digital Input (1): Start/Stop cycle control
  • Digital Output (s): Configurable as alarm contacts
  • Remote access: Windows Remote Desktop
  • Internal data storage: >10 years
  • Security: 2-level password protection

Optional Communications

  • Additional 4-20mA: Passive, Configurable for measurement readings/temperature
  • Advanced Sensors In-line Oil HART: Yes
  • Modbus RTU: Implemented via HART to Modbus converter
  • Extended Ethernet: 2-wire connection, capable of 1.3km distance

Additional Information

  • Hot insertion/extraction: Up to 100barg
  • Flange fitting: 2” ANSI RF (Various flange ratings available upon request)
  • Wetted parts: 316L SS (other materials available upon request)
  • Enclosure Material: 316L SS
  • Advanced Sensors In-line Oil Conduit Length: Up to 50mǂ
  • Dual probe (SA-100P2/1000P2): Allows dual simultaneous measurement

* Dependent on sample matrix & instrument configuration. Users may select any desired measurement from 0-10ppm, 0-100ppm […] up to 20,000ppm.
**Under ideal conditions, with a homogenized sample.
ǂ Please contact ASL to discuss conduit length over 30m.

Download Datasheet: Advanced Sensors SA-100P(2)/1000P(2) In-line Oil In Water Analyzer