Categories: Sensor

E2FM Omron Proximity Sensor with All stainless Housing

Stainless Housing E2FM Proximity Sensor

Omron Proximity Sensor use high-frequency oscillation. They resist heat, chemicals, and water better than Rectangular Sensors. They are available in both shielded and unshielded models.

E2FM Omron Proximity Sensor are available in models using high-frequency oscillation to detect ferrous and non-ferrous metal objects and in capacitive models to detect non-metal objects. Models are available with environment resistance, heat resistance, resistance to chemicals, and resistance to water.

Features

  • Completely stainless-steel housing
  • Aluminum chip immunity
  • Embedding installation to metal (steel) fittings
  • Chemical resistance certified by Ecolab Europe
  • The lineup includes pre-wire models and DC 3-wire NPN output models with fluororesin

Rating and Specifications

Size Shielded

Item                     Model

M8 M12 M18 M30 M12 M18 M30
Shielded
E2FM-X1R5D1-@ E2FM-X2D1-@ E2FM-X5D1-@ E2FM-X10D1-@ E2FM-X2D1- M1T1GJ-T E2FM-X5D1- M1T1GJ-T E2FM-X10D1- M1T1GJ-T
Sensing distance 1.5 mm±10% 2 mm±10% 5 mm±10% 10 mm±10% 2 mm±10% 5 mm±10% 10 mm±10%
Set distance 0 to 1.05 mm 0 to 1.4 mm 0 to 3.5 mm 0 to 7 mm 0 to 1.4 mm 0 to 3.5 mm 0 to 7 mm
Differential travel 15% max. of sensing distance
Sensing object Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on page 7.)
Standard sensing object Iron,

8 ´ 8 ´ 1 mm

Iron,

12 ´ 12 ´ 1 mm

Iron,

30 ´ 30 ´ 1 mm

Iron,

54 ´ 54 ´ 1 mm

Iron,

12 ´ 12 ´ 1 mm

Iron,

30 ´ 30 ´ 1 mm

Iron,

54 ´ 54 ´ 1 mm

Response frequency *1 200 Hz 100 Hz 100 Hz 50 Hz 100 Hz 100 Hz 50 Hz
Power supply voltage (operating voltage range) 12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.
Leakage current 0.8 mA max.
Output configuration With polarity No polarity

Control output

Switching capacity 3 to 100 mA
Residual voltage 3 V max.

(Load current: 100 mA max., Cable length: 2 m)

5 V max.

(Load current: 100 mA max., Cable length: 2 m)

Indicators Operation indicator (red LED), Setting/Operation indicator (green LED)
Operation mode (with sensing object approaching)

NO *2

Protection circuits Surge suppressor, Load short-circuit protection
Ambient temperature range Operating/Storage: -25 to 70°C (with no icing or condensation)
Ambient humidity range Operating/Storage: 35% to 95% (with no condensation)
Temperature influence ±20% max. of sensing distance at 23°C in the temperature range of -25 to 70°C.
Voltage influence ±1% max. of sensing distance at a rated voltage in the rated voltage ±15% range
Insulation resistance 50 MÙ min. (at 500 VDC) between current-carrying parts and case
Dielectric strength 1,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case
Vibration resistance Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions

 

Shock resistance

Destruction: 500 m/s2

10 times each in X, Y, and Z directions

 

Destruction: 1,000 m/s2 10 times each in X, Y, and Z directions

Degree of protection IEC 60529 IP67
Connection method Unmarked: Pre-wired Models (Standard cable length: 2 m)

Models ending with -M1GJ-@: Pre-wired Connector Models (Standard cable length: 300 mm)

Size Shielded

Item                     Model

M8 M12 M18 M30 M12 M18 M30
Shielded
E2FM-X1R5D1-@ E2FM-X2D1-@ E2FM-X5D1-@ E2FM-X10D1-@ E2FM-X2D1- M1T1GJ-T E2FM-X5D1- M1T1GJ-T E2FM-X10D1- M1T1GJ-T

Weight (packed state)

Pre-wired Models (2 m) Approx. 105 g Approx. 190 g Approx. 215 g Approx. 295 g
Pre-wired Connector Models

Approx. 65 g

Approx. 85 g

Approx. 110 g

Approx. 190 g

Approx. 85 g

Approx. 110 g

Approx. 190 g

 

 

 

Materi- als

Case Stainless steel (SUS303)
Sensing surface

(thickness)

Stainless steel (SUS303)
(0.4 mm) (0.8 mm) (0.8 mm)
Clamping nuts Stainless steel (SUS303)
Cable PVC (flame retardant)
Toothed washer Zinc-plated iron
Accessories Instruction manual

 

*1. The response frequency of the DC switching section is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and a set distance of half the sensing distance.

*2. NC (normally closed) models are also available. Contact your OMRON representative.

Download Catalog: Proximity Sensor with All-stainless Housing E2FM