The Hengesbach PZM 100/101 pressure transmitters are suitable for taking pressure and filling level measurements in pipelines and containers. The modular process connection system offers a wide range of connection adapters and helps to cut costs in the long term.
The flush-mounted process connection with O-ring seal and stainless steel membrane is certified to EHEDG type EL-ASEPTIC CLASS 1 and is thus predestined for measurements which satisfy even the most stringent hygiene requirements.
The sensor measuring ranges of the piezoresistive vacuum-proof measuring cell with stainless steel membrane of the Hengesbach PZM pressure transmitters range from -1/0…0.35bar to -1/0…100bar.
Special measuring ranges are possible for both versions. All the pressure transmitters in series 100/101 are designed for universal applications and, in particular, for applications with constantly high temperatures of up to 200°C. Furthermore, using the on-site display with series 100 and the display and operating module OPUS M in series 101, the pressure transmitters can be simply read out, configured and diagnosed.
Features: Hengesbach PZM
- EHEDG-aseptic certified modular process connection system
- precise measurements ≤ ± 0,15% FS
- Turn Down 10
- integrated or external display and operating module OPUSM
- vacuum proof and extremely overload safe
- direct entry of parameters with plain text display
- easy to clean and high protection classes IP 67 and IP69K
- application strengths: content and process pressure measurements / vacuum measurements even at high temperatures
Specification: Hengesbach PZM
General details | |||||||||
Device type / measuring principle | PZM 100/101: piezoresistive | ||||||||
VRM 100/101: capacitive | |||||||||
Input | |||||||||
Measuring ranges | PZM 100/101 | VRM 100/101 | |||||||
Standard nominal measuring range [bar] | relative | OP | absolute | OP | relative | OP | absolute | OP | |
OP = overload protection [bar] | 0…0.35 | 1 | 0…4 | 25 | |||||
0…1 | 3 | 0…1 | 3 | -1/0…4 | 25 | 0…10 | 40 | ||
-1/0…2.5 | 8 | 0…2.5 | 8 | -1/0…10 | 40 | 0…20 | 40 | ||
Special measuring ranges are available on request. | -1/0…5 | 15 | 0…5 | 15 | -1/0…20 | 40 | 0…40 | 60 | |
-1/0…10 | 30 | 0…10 | 30 | -1/0…40 | 60 | 0…70 | 105 | ||
-1/0…30 | 90 | 0…30 | 90 | -1/0…70 | 105 | ||||
-1/0…100 | 250 | 0…100 | 250 | ||||||
Setting the measuring ranges | Via the keypad of the OPUSM display and operating module / via the integrated on-site display | ||||||||
Setting ranges | Start the measuring zero: | 0…90% of the sensor’s nominal measuring span | TD=10 | ||||||
Measuring span: | 10…100% of the sensor’s nominal measuring span | ||||||||
Burst pressure DIN16086 | ≥ 4-fold measuring range | ||||||||
Output | |||||||||
Output signal | 2-wire: 4…20mA with a test circuit connection in the device | ||||||||
Fault signal | Optional: 3.8mA, 22mA, hold (i.e. holding the last value) | ||||||||
Current limitation | 3.85mA and 21.5mA (normal operation) | ||||||||
Integration time | Continuously selectable between 0 and 300s (setting time after a pressure leap) | ||||||||
Measuring accuracy | |||||||||
Reference conditions | acc. to DIN IEC 770 | ||||||||
Linearity, hysteresis and repeatability as per the limit point method DIN IEC 770 | ≤ ± 0.15% of the sensor’s nominal measuring range | ||||||||
DIN IEC 770 | |||||||||
Activation time | < 5s (the device will carry out a self-test.) | ||||||||
Setting time (without damping) | < 200ms | ||||||||
Long-time drift | ≤ 0.2% of the span per year | ||||||||
Thermal hysteresis | ≤ ± 0.75% beginning of the measuring range / ≤ ± 0.8% end of the measuring range (VRM) | ||||||||
≤ ± 0.2% of the sensor’s nominal measuring range / 10K (-20…+80°C) from 4 bar (PZM) | |||||||||
≤ ± 0.3% of the sensor’s nominal measuring range / 10K (-20…+80°C) up to 0.6 bar (PZM) | |||||||||
Conditions of use | |||||||||
Installation position / calibration position | Any position / standing vertically | ||||||||
Medium temperature | PZM: | T1: | -40…+125°C (140°C over one hour at the most) | ||||||
T2: | -40…+200°C (high-temperature version) | ||||||||
VRM: | -40…+140°C | ||||||||
Ambient storage temperature | Type 101: | -40…+85°C | |||||||
Type 100: | -30…+75°C | ||||||||
(Below -20°C cable breakage might occur and the display’s function may be impaired.) | |||||||||
Protection class acc. to EN60529 | IP 67 and IP 69K | ||||||||
Electromagnetic compatibility | Sensitivity against interference: acc. to DIN IEC 61000-6-2 | ||||||||
Interference radiation: | acc. to DIN IEC 61000-6-4 | ||||||||
Construction | |||||||||
Electrical connection | – Standard: cable screw connection M16x1.5, nickel-plated brass, stainless steel available on request | ||||||||
– Optional: round plug-in connector M12x1, nickel-plated brass, stainless steel available on request | |||||||||
– Optional: angle plug acc. to EN 175301-803 | |||||||||
– Optional: reference cable | |||||||||
Process connection | – Membrane, flush-welded on the front, CrNiSt, other materials available on request | ||||||||
– EHEDG type EL-ASEPTIC CLASS 1, certified connection system PZM / VRM | |||||||||
with press screw M38x1.5 and elastomer sealing | |||||||||
– Process seal EPM (FDA) (temperature range: -20…+150°C) | |||||||||
– Process seal FPM (FDA) (temperature range: -40…+200°C) | |||||||||
Materials | – Field housing / lid: | CrNiSt 1.4301 (304) | |||||||
– Housing seal: | FPM (Viton®) | ||||||||
– Pressure compensation element: | polyamide | ||||||||
– Inspection gauge (type 100): | polycarbonate | ||||||||
– Process connection/connection adapter: | CrNiSt 1.4404 (316L) | ||||||||
– Process membrane: | CrNiSt 1.4435/1.4404 (316L) | ||||||||
– Locking screw (type 101): | CrNiSt 1.4301 (304) | ||||||||
– Reference cable: 5-wire with reference tube: PUR (recommended: 80m maximum) | |||||||||
Filling fluid | PZM: | silicon oil (FDA) | |||||||
VRM: | medical mineral oil (FDA) | ||||||||
Display and operation | |||||||||
Display | LCD, 4-digit numerical display, and 5-digit alphanumerical display | ||||||||
Type 100: | integrated on-site display (cannot be separated from the device) | ||||||||
Type 101: | external OPUSM display and operating module | ||||||||
Displayable units | Pressure: | mbar, bar, psi, Pa, mH2O, mmHg, Torr, atm, at, kg/cm² | |||||||
Temperature*1: | °C, °F, K, °R, °Ré | ||||||||
Additional displays | Output current in mA or % (in relation to the span) | ||||||||
Operation | 100.00.00 | via the configuration menu with the integrated on-site display | |||||||
101.00.00 | via the configuration menu with the external OPUSM display and operating module | ||||||||
Auxiliary energy resources | |||||||||
Power supply/burden | 12-36V DC, max. burden: (V supply – 12V) / 24mA | ||||||||
Accessories 100 series | |||||||||
OPUSM display and operating module | External display and operating module, CrNiSt, IP 67, 41x70mm, 1m connection cable and round plug-in connector M12x1 | ||||||||
Certificates | Calibration certificate | ||||||||
Declaration of conformity | |||||||||
Material inspection certificates as per EN 10204 | |||||||||
EHEDG certificate |
Download Data Sheet: Flush-Mounted Pressure and Level Transmitter PZM 100_101 Series
Other Article:
- LEEG Pressure Transmitter, Sensor and Switch
- D22 Pressure Transmitter Delta Mobrey
- 8000 SAN Pressure Transmitter Delta Mobrey
- Differential Pressure Transmitter D32 Series Delta Mobrey
- Pressure Transmitter 2HT Series Delta Mobrey
Ref: Hengesbach.com