Flush-Mounted Pressure Transmitter TCS Type Hengesbach

Hengesbach TCS Pressure Transmitter  Descriptions

Flush-Mounted Pressure Transmitter TCS Type Hengesbach are ceramic-sensor-based, flush-mounted pressure transmitters with metal membrane – Type TCS – for relative andabsolute pressure with various sensor elements are available with manometer connection or flush-mounted membrane. This connecting concept allows highly overload-resistant pressure measurements and provides high operating safety for industrial process pressure and level measurements.

The devices are cast into stainless steel standard housings and are available according to protection types from IP65
onwards. High-temperature versions for continuous operation at up to 200 ºC are available. Vacuum-resistance guaranteed. Installation into pipes with small nominal diameters is easily possible, due to the compact design.

Appropriate welding sockets and process adaptors can be ordered. The two process connection variants are G ½ or M22x1.5 with a threaded connection. In addition to the standard housing, a field housing design can be selected.

Features:

  • high overload safety for flush mounted applications with o-ring seal
  • measuring ranges from 0…2 bar to 0…400 bar for relative and absolute pressure in standard design
  • high-temperature safe up to 200ºc continuous load
  • shock- and vibration-resistant
  • different process connection adaptors

Specification:

ApplicationsAbsolute and relative pressure measurement in gases, vapours and liquids
Measuring principleThe process pressure acts on the metallic separation membrane of the sensor and is transmitted to the resistance bridge via the filling liquid. The change in output voltage proportion to the pressure is measured.
Input
Measuring ranges (depending on type of device)Relative pressureAbsolute pressure
relativeÜSIrelativeÜSIabsoluteÜSIabsoluteÜSI
Nominal measuring ranges (bar)2bar5100bar2502 bar5200 bar500
ÜSI = Overload protection (bar)02.05bar8200bar5005 bar12400 bar600
5bar12400bar60010 bar25
10bar2520 bar50
20bar5050 bar120
50bar120100 bar250
Adjustable rangesMeasuring span  ± 20%
Zero point ± 20%
Output
Output signal4…20 mA, 2-wire circuit
Working resistanceRb (2-wire),  ≤ Us – 13 V, Us = supply voltage
 0,02A , L129 , Rb = working resistance
Breakdown signaltypical 34 mA, max. 40 mA
Measuring accuracy
Reference conditionsAccording to. EN 60751, Ta = 20°C
Linearity≤ ± 0.4% of the set measuring range, limit point method according to DIN IEC 770
Warm-up time1 s
Rise time≤ 10 ms (without attenuation)
Long-term drift≤ 0.4% relative to the initial measuring range
Temperature coefficient± 0.4% FS / 10 K for zero point, compensation range 0…70°C
± 0.2% FS / 10 K for measuring range
Effect of vibration1.5 mm (10…55 Hz)
Installation positionVertical (above 4 bar no restrictions)
Conditions for use
Medium temperature-40°C… + 125°C, 140°C max. for 1 h (type HT for temperatures up to 200°C)
Environmental temperature -40°C… + 85°C
Storage temperature -40°C… + 85°C
Protective type acc. to EN 60529– IP 65  (with plug connection acc. to EN 175301-803)
0 (with permanently attached reference cable or M12x1 plug)
Electromagnetic compatibilityEMC directives according to EN 50081-2 / 50082-2 are fulfilled, CE-sign
Design configuration
TypeVA rod housing and process connections, flush-mounted
Material– Standard housing made of 1.4301
– Process connections made of 1.4404
Electrical connection–  Standard: Plug connection acc. to EN 175301-803
–  optional:  Permanently connected reference cable, length 1 m
– optional:Round plug M12 x 1
Filling liquidSilicon oil (suitable for food products, FDA), white oil (FDA)
Auxiliary energy
Supply voltage13…30 DC, max. permissible residual ripple 1 Vss
Supply voltage effect≤±0.03%


Download Data Sheet: Flush-Mounted Pressure Transmitter TCS Type