H2Scan HY-ALERTA 1600 Intrinsically Safe Area Hydrogen Monitor

Description

H2Scan HY-ALERTA 1600 Intrinsically Safe Area Hydrogen Monitor provides hydrogen-specific leak detection and measurement for hydrogen concentrations as low as 4000 ppm and can be scaled to any concentration up to 5% hydrogen by volume, a range representing 10% to 125% of hydrogen’s low flammability limit.

The monitor is designed for either ceiling or wall mount and has an RS422 capability that extends an intrinsically safe interface from the hydrogen sensor to the controller to several hundred feet.  H2scan’s hydrogen-specific sensor technology has no cross-sensitivity to other combustible gases, thus eliminating false positive alarms and ensuring safety system reliability. An example application where this product and its benefits have been demonstrated is in the measurement of hydrogen in a Hydrogen-cooled Generator.

H2Scan HY-ALERTA 1600 Applications

  • Battery Rooms
    • H2 monitoring during lead acid battery charging
  • H2 monitoring during lead acid battery charging
    • Leak detection during operation
  • Control Rooms / Analyzer Buildings
    • Detection of potentially flammable H2 buildup in occupied areas
  • Industrial Gas Supply and Hydrogen Production
    • Leak detection around H2 storage facilities and pipes
  • Laboratories
    • General hydrogen safety monitoring
  • Furnaces and Manufacturing
    • Area monitoring for unburnt hydrogen
  • Alternative Energy
    • Hydrogen refueling station safety monitoring fuel cell and electrolyzer leak monitoring
  • Other Applications
    • General area monitoring wherever there is a risk of hydrogen accumulation

Advantages

  • Highly reliable
  • Wide hydrogen-specific detection range
  • H2Scan Intrinsically Safe Area: Low life cycle cost
  • Works in air, oxygen, or inert gas background
  • Easy to install and operate
  • Does not degrade over time
  • Minimal maintenance required
  • Non-consumable solid-state technology
  • No cross-sensitivity to combustible gases
  • Field-configurable settings
  • Not vulnerable to poisoning like other detectors
  • Will not saturate with exposure to hydrogen

H2Scan HY-ALERTA 1600 Performance

  • Hydrogen Sensitivity Range: 0.4% to 5% hydrogen by volume, 10% to 125% hydrogen lower flammable limit
  • Accuracy: ± (0.03 x indication + 0.2) percent hydrogen by volume
  • Typical Response Time: T90 of 60-sec maximum
  • Ingress Protection: IP64 capable
  • Calibration Interval: 90 days
  • Product Life Expectancy: 10 years

Interface Options

  • Power Barrier Input Voltage: 24 VDC nominal
  • Power Barrier Input Voltage Range: 20 VDC to 28 VDC
  • Intrinsically Safe Sensor Input Voltage: 10 VDC
  • Sensor Input Voltage Range: 5 VDC to 28 VDC
  • Input Power: 10 W
  • Analog Output: 4 mA to 20 mA
  • Serial Communication: RS422

Operating Conditions

  • Operating Humidity: 0% to 95% RH
  • Operating Temperature Range: -20ºC to 40ºC
  • Storage Temperature Range: -40ºC to 50ºC
  • Calibration Background Gas: Air

Included Accessories

  • Intrinsically Safe Power Barrier
  • Armored Power / Analog Cable: 4 m
  • Calibration Cup

Optional Accessories

  • Single Channel Intrinsically Safe Analog Output Barrier (with or without relays)
  • Single Channel Intrinsically Safe RS422 Serial Interface Barrier
  • Serial Interface Cable: 4 m (custom lengths available)
  • Armored Power / Analog Cable (custom lengths available)

Dimensions

  • Total Length: 8.1 in.
  • Total Width: 4.4 in.
  • Depth: 1.6 in.

HY-ALERTA™ is a registered Trademark of H2scan. Specifications are subject to change without prior notice.