Valcom Pressure Instrument

Since 1974 Valcom® designs, develops and manufactures instrumentation for measuring and control of storage of fluids and solids. Since the birth of Valcom® today many things have changed, and the company has been evolved in different aspects; from a logistical transfer and expansion of the sales department,

it has followed the technological evolution that the company has always tried to encourage and drive, on one hand making of own property some technologies once entrusted to third parties, on the other focusing on the internal research and development department.

 

Valcom Product

ModelFuctionMeasuring RangeProses Temperature
T7N Series• Level Continous-1∼ 0 barStandard: -40 ∼ +85°C
• Pressure0 ∼1000 barFinned body: -40 ∼ +130°C
Capillary: -40 ∼ +280°C
T7D Series• Level Continous-18 ∼ 18 mbarStandard: -40 ∼ +85°C
• Differential Flow-10000 ∼ 10000 mbarCapillary: -40 ∼ +280°C
ASL SeriesLevel On-Off (Switch)On-Off SwitchStandard: -40 ∼ +85°C
Finned Body T1: -60 ∼ +150°C
Finned Body T2: -200 ∼ +450°C
MFM SeriesFlow MultiphaseVariable (Multiphase)Standard: -40 ∼ +80
up to 283°C (On request)
MFU SeriesFlow MultiphaseVariable (Multiphase)Standard: -40 ∼ +80
up to 283°C (On request)
WGE SereisFlowVariable (Multiphase)WGE body: -40°∼ 280°C
With integral manifold: -40°C ∼ 180°C
SPG SeriesGauge0 ∼ 1(std) … up to 10 (optional) mH2O-20 ∼ +130°C
LSG SeriesLevel On-Off (Switch)On-Off SwitchStandard: -20 ∼ +85°C
Finned body: -40 ∼ +130°C
T7W SeriesWater in Oil0 ∼ 45% Concentration of Water in Oil-10 ∼ +150°C
T76 Series• Level Continous-1 ∼ 0 barStandard: -40 ∼ +85°C
• Pressure0 ∼ 1000 barFinned body: -40 ∼ +130°C
Capillary: -40 ∼ +280°C
T79 Series• Level Continous-1 ∼ 0 barStandard: -40 ∼ +85°C
• Pressure0 ∼ 1000 barFinned body: -40 ∼ +130°C
Capillary: -40 ∼ +280°C
T7I Series• Level Continous-1 ∼ 0 barStandard: -40 ∼ +80…283°C
• Pressure0 ∼ 1000 bar
T7L SeriesLevel Continous0.6 ∼ 10 mStandard: -40 ∼ +85°C
Finned body: -40 ∼ +130°C
KRG SeriesLevel Continous0 ∼ 30 mCone and Rod Antenna: -40 ∼ +150 °C
PTFE Antenna: -40 ∼ + 200 °C
T7T SeriesTemperatureStandard: -40 ∼ +85°CStandard: -40 ∼ +85°C
Nipple-Union-Nipple: Tmax = 150°CNipple-Union-Nipple: -40 ∼ +150°C
Remote: Tmax = 350°C or 500°CRemote: -40 ∼ +500°C
T7B Series• Pressure0.3 ∼ 10 m-100 ∼ +200°C (Finned: +350°C)
• Density
T7V seriesAccessoriesNot Applicable4 ∼ 20 mA
T7C seriesConsistency1.50 ∼ 12 % CS+5 ∼ +90°C
T7S seriesDensity0…250 g/lStandard: -10 ∼ +130°C
0…3000 g/l
T7M SeriesTemperature0∼50 (std)… up to 300(on request) °CStandard: -40 ∼ +85°C
OMD SeriesOil Mist0 ∼ 2 mg/l-20 ∼ 70 °C
T72 seriesLevel Continous0 ∼ 0,35 bar-10 ∼ +80°C
0 ∼ 50 bar
BMS SeriesSystemsNot ApplicableStandard: -40 ∼ +85°C
HMI SeriesSystemsNot ApplicableStandard: +5 ∼ +60 °C
THP seriesPressureMax: 0 ∼ 8 bar-10 ∼ +80°C
Min: 0 ∼ 1.5 bar
18I seriesLevel Continous0 ∼ 1 bar-10 ∼ +80°C
0 ∼ 100 bar
27A seriesPressure-1 ∼ 0 barStandard: -40 ∼ +85°C
0 ∼ 1000 barFinned body: -40 ∼ +130°C
Capillary: -40 ∼ +280°C
M3 seriesAccessoriesNot ApplicableStandard: -40 ∼ +85°C
27I seriesLevel Continous-1 ∼ 0 bar-40 ∼ +85°C
0 ∼ 1000 bar
27D series• Level Continuous-0.1 ∼ 0 barStandard: -40 ∼ +85°C
• Differential Pressure0 ∼ 16 barCapillary: -40 ∼ +280°C
27L seriesLevel ContinuousStarting from 0 ∼ 0.5 mStandard: -40 ∼ +85°C
Finned body: -40 ∼ +130°C
86A series• Level Continuous< ± 0.25 % FS-40 ∼ +85°C
• Pressure
27M seriesPressure0 ∼ 0.003 bar-40 ∼ +85°C
0 ∼ 16 bar
JBX seriesAccessoriesNot Applicable-20 ∼ +125°C
LSG-02 seriesLevel On-Off (Switch)On-Off SwitchStandard: -20 ∼ +85°C
Glass Reed Relay: -40 ∼ +130°C
TSU seriesAccessoriesNot Applicable-20 ∼ +55°C
VCM seriesAccessoriesNot ApplicableStandard: -40 ∼ +85°C
M1 seriesAccessoriesNot ApplicableStandard: -40 ∼ +85°C
M2 seriesAccessoriesNot ApplicableStandard: -40 ∼ +85°C
M5 seriesAccessoriesNot ApplicableStandard: -40 ∼ +85°C
HART® ServerSoftwareNot ApplicableNot Applicable