Lower and upper parts of measuring chamber are spherical in shape. Inside the chamber is the disc, which is set in motion by the liquid. The flow causes an oscillating movement of the disc, opening and closing alternately the inlet and outlet orifices of the measurement chamber. The frequency of disc oscillations is magnetically transmitted to the totalizer.
The water-meter must be installed on a horizontal pipe, full of liquid.
BCP 48: Counter/ down counter
These water-meters are suitable for totalization of clean or slightly dirty liquids, raw water or demineralized water.
Flow ranges | M25: 1 to 100 l/min |
M40: 2 to 160 l/min | |
Viscosity | 500 cPo |
Nominal pressure | PN 16 |
Temperature | Max. 50 °C |
Accuracy | ±1.5% |
Download Data Sheet: Water-Meter in Plastic M 25 – M 40
Ref: bamo.eu