Hengstler ROS Safety Relays is a product from Hengstler. This product comes from safety relay categories. Due to the constant high number of electrical switching cycles, the new H-480 can be used for a broad range of safety applications.
For decades, HENGSTLER has been intensively involved in matters relating to forcibly guided, or captive, contacts and, as a result, with safety relays. Our large, international customer base benefits from this experienced gathered over many years when it comes to developing and manufacturing relays with forcibly guided contacts.
Function / Application | Safety relay |
Product line | KACO |
Relay family | ROS |
Contact set | forcibly guided |
According EN 50205 | Application type A |
Ambient temperature [°C] | -15 … +70 °C |
Soldering heat resistance [°C] | 260 °C |
Max. soldering time [s] | 5 s |
Pins pre-soldered with | Sn 100 |
Approval | TÜV |
cULus | |
Standards | EN 50205 |
IEC 61810-1 | |
UL 508 | |
Meets the requirements | RoHS |
Number of NO contacts | 2 … 3 |
Number of NC contacts | 1 … 2 |
Number of CO contacts | 0 |
Dimensions L x W x H [mm] | 42,0 x 16,0 x 32,2 mm |
Housing | dustproof (RT II) |
Shock resistance NO / NC [g] | 30/30 g |
Puls duration (half sinus) | 11 ms |
Vibration resistance NO / NC [g] | 5/5 g |
Frequency range [Hz] | 10 – 55 Hz |
Operating time NC contact, contact opens [ms] | 9 ms |
Operating time NO contact, contact closes [ms] | 12 ms |
Releasing time NO contact, contact opens [ms] | 5 ms |
Releasing time NC contact, contact closes [ms] | 8 ms |
Mechanical service life (without load) | 10,000,000 switching cycles |
Connection type | Solder pins for pcb |
Weight [g] | 35 g |
Drive system | DC monostable |
Nominal coil voltage [V] | 6 … 250 V |
Coil resistance [Ohm] | 25 … 66,000 Ohm |
Contact material | AgNi + 0,2 … 10 µm Au |
AgSnO + 0,2 … 2 µm Au | |
Max. switching current [A] | 6.00 AM |
Max. switching voltage [V] | 230/240 V |
Max. switching capacity [VA] | 1840 VA |
Switching capacity AC-15 at 230 V [Ie in A] | 4.00 AM |
Switching capacity DC-13 at 24 V [Ie in A] | 1,2 A |
Electrical service life (with nominal load) | 100,000 cycles |
Short-circuit capacity 1000 A / AC 230 V [A] | 8.00 AM |
Insulation | Basic insulation |
Download Data Sheet: Safety Relays Type ROS