Overview
Katronic KATflow 170 provides a corrosion-resistant option as part of a fully ex-certified package for applications where harsh environmental conditions demand a more rugged instrument. The flow meters is intended for permanent operation in Zone 1 and 2 hazardous areas and is an economical choice for a variety of metering applications. The KATflow 170 demonstrates that even the most complex technical requirements can be met with straightforward solutions.
The KATflow 170 flow meters is designed around a choice of explosion-proof housings available in either offshore industry compliant epoxy-coated copper-free aluminium, or stainless steel. The instrument is extremely easy to use and is programmed with a magnetic pen and a glass-fronted keypad for increased safety. The robustness and reliability of the KATflow 170 is further enhanced by its encapsulated IP 68 transducers which are manufactured from stainless steel and have a sturdy cable conduit.
Katronic KATflow 170 Feature
- Suitable for installation in hazardous areas
- Dual flow monitoring with sum, average, difference and maximum calculations
- IP 68 stainless steel sensors as standard
- Process output options including current,open-collector, relay
- Communication options RS 485, Modbus RTU,Profibus PA and HART compatible output
- ATEX-certified PT100 probe for temperaturecompensation
Application
- Oil and Gas
- Oil blending skids
- Produced water measurements
- Methanol and water injection systems
- Product recognition and interface detection systems
- Coiled tubing systems
- Petrochemical
- Measurement of refined products
- Measurement of corrosive or toxic chemicals
- Boiler feedwater measurements
- Marine and Shipbuilding
- Tanker unloading systems
- Fire suppression systems
- Water and Wastewater
- Effluent measurement in hazardous areas
- General Industry
- Distillery process measurements
- Automated process control
- Production chemical measurements in hazardous areas
Specification
| Flow velocity range | 0.01 … 25 m/s |
| Resolution | 0.25 mm/s |
| Repeatability | 0.15 % of measured value, ±0.015 m/s |
| Accuracy | Volume flow: |
| ±1 … 3 % of measured value depending on application | |
| ±0.5 % of measured value with process calibration | |
| Flow velocity (mean): | |
| ±0.5 % of measured value | |
| Turn down ratio | 1/100 (equivalent to 0.25 … 25 m/s) |
| Measurement rate | 100 Hz (standard) |
| Response time | 1 s (standard), 90 ms (optional) |
| Damping of displayed value | 0 … 99 s (selectable by user) |
| Gaseous and solid content of liquid media | < 10 % of volume |
| Power supply | 100 … 240 V, AC 50/60 Hz |
| 9 … 36 V DC | |
| Temperature range | -50 °C to +115 °C (-58 °F to +239 °F |
Download : Datasheet Katronic KATflow 170
For futher info please contact us, sales@wmablog.com
Ref: https://www.katronic.com/
Other Article:
- Seametrics EX800 Fixed Depth Insertion Magmeter
- Onicon F3500 Series Insertion Electromagnetic Flow Meter
- PE 202 Seametrics Low-Flow Magmeter
- Alia AMF301 electromagnetic water flow meter
- Yokogawa ADMAG Magnetic Flowmeters