Bamo BAMOFLONIC – PFA Ultrasonic Flow Meter

Bamo BAMOFLONIC – PFA Ultrasonic Flow Meter

Bamo BAMOFLONIC – PFA Ultrasonic Flow Meter applies propagation ultrasonic waves principle to measure the speed of a liquid, then to calculate the corresponding flow-rate. Therefore, it is convenient for liquids electrically conductive or not. Note: The liquid must be homogeneous and clear. As no moving parts are concerned, BAMOFLONIC operates without mechanical wear. Wet parts are of PFA.

BAMOFLONIC – PFA can operates without its remote display unit. If liquid properties are different to water (viscosity, waves propagation, etc.), it is recommended to use the remote display unit. It allows to display and modify the flow-meter parameters (output signals, reset of totalizer, dosing function, etc.).

Bamo BAMOFLONIC – PFA Ultrasonic Flow Meter Features:

  • 4 models ND 7 to ND 20
  • Measuring ranges from 0.09 up to 120 l/min
  • Wet parts in PFA; Casing in PP
  • 1 Analogue output 0/4-20 mA
  • 1 Digital output, to set up

Application:

Flow measurements or dosing sequences of aggressive or neutral liquids:

  • Chemicals strongly alkaline or acidic
  • CIP (Clean In Place)
  • Lixiviates, etc.

Another Article:

Specification:

Power supply 24VDC/3.6W
Outputs 1 Digital output (to set as pulses or empty tube alarm,
reverse flow, dosage, min. or max. flow-rate)
1 Analogue output 0/4-20 mA
Interface For settings and/ or display on remote unit
Connector M12, 5 pins (included)
Accuracy ± 2 % of reading and ± 0.3 mm/s
Repeatability ≤0.5%
Liquid temperature 0… +60 °C
Pressure 6 bar at 20 °C
Protection IP 65
Fittings Quick coupling connectors (flare type, see the table)
Materials Body: PFA (Perfluoralkoxy); Casing: PP

Options:

To launch a dosage (Connector M12 8 pins)
Digital input
Accuracy ± 1 % of reading and ± 0.3 mm/s

Download Data Sheet: Ultrasonic Flow-Meter BAMOFLONIC – PFA

Ref: bamo.eu

Share