Kobold KSM Variable Area Flow Meter and Switches Plastic

Description

Kobold KSM Variable Area Flowmeters and Switches Plastic are based on the float principle with the float moving freely without friction in the measuring tube. From nominal size DN65 the devices are provided with a guide rod to stabilize the floats. The indication point is at the greatest diameter of the float. The standard flowmeters are supplied with a scale for water (+20°C), a percentage scale, O-rings, two setpoint indicators and a guide rail for accessories.

The measuring tube is available in polysulfone (KSM2…) for less aggressive media or in Trogamide (model KSM-1…) for simple water or air applications. The materials are resistant to impact, bending and compressive stresses. Optional threaded fittings can be fitted on the external threads integrally extruded at the ends. The floats are supplied with integrated magnets for operation with a bistable reed contact.

Kobold KSM Special Advantages

  • Rugged and corrosion resistant
  • Special scales can be attached
  • Guide rails for limit switches (can also be retrofitted, only replacement of thefloat is necessary).
  • Nominal sizes, measuring range and measuring tube material are all marked on the measuring tube.

Applications

  • Cooling circuits
  • Water treatment
  • Plant engineering

Specifications

  • Measuring / switching range:
    • 15 – 150 … 8000 – 60 000 l/h water
    • 0.8 – 5 … 300 – 2500 m³/h air (0 bar rel, 20°C)
  • Connection: ½” … 3½”
  • Material: trogamide-T, polysulfone
  • pmax: 16 bar
  • tmax: 60°C (trogamide), 100°C (polysulfone)
  • Accuracy: Cl. 4 according to VDI
  • Option: reed contact

Kobold KSM Technical Details

Housing:KSM-1…: Trogamide-T
KSM-2…: Polysulfone
Connections:see table Order Details of datasheet
Float:PVDF
Guide rod:PVDF stainless steel for the 3 largest sizes
Seals:EPDM (KSM-1… / KSM-2…)
Max. temperature:KSM-1…: 0-60°C
KSM-2…: 0-100°C
with contact max. 85°C
Max. pressure:KSM-x0xx, KSM-x1xx: 16 bar KSM-x201, KSM-x301, KSM-x601: PN10
Accuracy:±4% of full scale
Repeatability:?1%

Download Datasheet: KSM Kobold Variable Area Flowmeters and Switches-Plastic