Fluidwell F112 Flow Rate Indicator/Totalizer

Introduction

The Fluidwell F112 is a versatile flow rate indicator/transmitter and totalizer with the ability to precisely linearize the flowmeter signal. In addition to the average K-Factor or Span, fifteen linearization points can be entered with their frequencies or values. The unit will interpolate between these points, greatly enhancing accuracy in any flow range, even for very low-frequency applications. This linearization affects all displayed information as well as the output signals.

Fluidwell F series Flow Rate and totalizer
Fluidwell F series Flow Rate and totalizer

Intrinsically Safe

The display shows flow rate, total, and accumulated total. On-screen engineering units are easily configured from a comprehensive selection.

Advantages

  • Robust aluminum or stainless steel 316L field enclosure (IP66, IP67 / NEMA Type4X).
    It is so rugged, a truck can even stand on it!
  • Intrinsically Safe available – ATEX and IECEx approval for gas and dust applications.
  • Familiar easy operation with the Fluidwell “Know one, know them all” configuration structure, saving time, cost and aggravation.
  • Very diverse mounting possibilities: walls, pipes, panels or directly onto outdoor sensors.

Features

  • Fifteen point linearization of the flow curve – with interpolation.
  • Accumulated total – not resettable: eleven 8mm (0.31″) digits.
  • Analog and pulse outputs.
  • LED backlight.
  • Displays total and flow rate simultaneously.
  • Flow rate: seven 17mm (0.67″) or 8mm (0.31″) digits.
  • Total – resettable: seven 17mm (0.67″) digits.
  • Ambient temperature: -40°C to +80°C (-40°F to 176°F).
  • Separate engineering units for flow rate and total on the display.
  • The remote control input to reset total or to lock the “clear total” button.
  • Intrinsically safe according to ATEX and IECEx.
  • Large digit selection for flow rate or total.
  • GRP, Aluminum, or high-grade stainless steel enclosure.
  • Auto backup of settings and running totals in EEPROM memory.
  • Various accessories are available for this product.

Applications

  • Liquid flow measurement with mechanic flowmeters where a precise calculation over the full measurement range is required. Also, re-transmission of the flow rate and/or totalizer functions or serial communication is desired.
  • The F-Series is your first and best choice for field mount indicators in safe and hazardous area applications. Especially in harsh weather conditions like rain, snow, sandy deserts, salty atmospheres, and temperatures between -40°C up to +80°C (-40°F up to 176°F).

Specification

Signal Inputs

  • Flowmeter Inputs

    • Pulse-type inputs:
      Reed-switch, NAMUR, NPN/PNP pulse, Sine wave (coil), active pulse signal.
    • (0)4 – 20mA.
  • Status Inputs

    • Remote control: external reset for clearing total or to disable manual clearing by the keypad.

Signal Outputs

  • Pulse outputs

    • Function: Scaled pulse output according to accumulated total (e.g. a pulse every 3.25 gallons).
      Max. frequency: 500Hz.
      Adjustable pulse length from 0.001 sec. to 9.999 seconds.
    • Type: One passive NPN transistor, active PNP transistor, or isolated electro-mechanical relay.
  • Alarm outputs

    • None
  • Analog outputs

    • Function: Re-transmitting the linearized flow rate – the output can be scaled to any range (e.g. 200 L/min to 1200 L/min).
    • Type: One passive isolated, floating, or loop powered 4 – 20mA output or one active (0)4 – 20mA or 0 – 10V DC output.

Supply

  • Power Supply

    • Long-life Lithium battery.
    • 4 – 20mA, input Loop-powered.
    • 8 – 24V AC/DC.
    • 115 – 230V AC.
    • Basic: 8 – 30V DC.
  • Sensor Supply

    • 3.2, 8.2, 12, 24V DC.

Hazardous Area

  • Intrinsically Safe

    • ATEX:
      Gas: II 1 G Ex ia IIC T4 Ga
      Dust: II 1 D Ex ia IIIC T100°C Da
    • IECEx:
      Gas: Ex ia IIC T4 Ga
      Dust: Ex ia IIIC T100°C Da
    • CSA:
      I.S. Class I/II/III, Div 1, Grp A…G, T4 Class I, Zone 0, AEx ia IIC T4
    • FM:
      I.S. Class I/II/III, Div 1, Grp A…G, T4 Class I, Zone 0, AEx ia IIC T4
  • Explosion Proof

    • ATEX:
      Gas: II 2 G / Ex d IIB T5 Gb
      Dust: II 2 D / Ex t IIIB T100°C Db

Communication

    • Modbus communication is available on F1-Series products.
      • HART communication is available with the F018 & E018 Flow rate Monitor / Totalizers

Characteristics

Measured value   : flow

Display  : LCD display

Type  : panel-mount

Other characteristics : 4-20 mA, analog output, intrinsically safe, pulse output

Applications : for hazardous areas

Download Datasheet: Fluidwell F112 Flow Rate Indicator