Description
Hengesbach DSA 1010 Digital Display for wall structures is suitable for 0/4…20 mA or 0…+10 V DC input signals. The measuring input is galvanically separated from the supply voltage. The transmitter supply allows direct connection of 2- and 3-wire transmitters, e.g. for pressure or temperature. Display range and decimal points are freely programmable within the digits ± 9999. The fact that several parameters can be programmed allows universal application of the device.
The DTA 1010 digital tank content indicator can determine the content of tanks of various shapes, even when there is no linear relationship between filling height and content, i.e. the system compensates for non-standardized tank shapes. The measurement is based on the hydrostatic pressure or differential pressure (with 2 pressure sensors) or on distance sensors (e.g. ultrasound, radar, potentiometer).
The device provides the option of connecting an additional level sensor. When a specific level is reached, the display is corrected to the value that corresponds to the filling height in the tank in which the level sensor has been installed. Programming is performed at the membrane keyboard in front. The alarm outputs can be programmed as min. or max. functions. The switching states are indicated by LEDs. When the digital filter is activated, the mean of 16 measuring values is continuously calculated and displayed. An analog signal in the range 0…20 mA / 0…10 V DC or 4…20 mA / 2…10 V DC that is proportional to the tank content is provided. Switching from a current to a voltage signal is load-dependent (> 500 Ω to voltage).
Hengesbach DSA 1010 Digital Display Features:
Hengesbach is a company from Deutschland. For more than 50 years Hengesbach develops, manufactures and distributes innovative measuring technology for applications in production processes where functionality, reliability and accuracy of the instruments are of highest priority even under extreme process conditions.
Hengesbach develop and produce measuring instruments with a clear focus on the worldwide active dairy, food and beverage industry. Especially within these applications, highest hygienic requirements for the production of safe products are essential prerequisites. The product of Hengesbach Such as level measuring, flow measuring, pressure measuring, temperature measuring, analytical measurement, evaluation. One of the product that come from Hengesbach is evaluation.
- for standard signals 0/4…20 mA and 0…10V DC
- Simple installation due to the wall structrue with field housing
- display range and decimal point freely programmable
- field housing with hinged LID
- optional with 2 alarm outputs, relay
Specification:
General information
Device type | DSA 1010 digital display for wall structures |
Applications | Display of standard signals |
Input
Current input | 0/4…20 mA; Ri = 10 Ω |
Voltage input | 0…10 V; Ri = <100 k Ω |
Potentiometer | 0…1 kΩ/100 kΩ |
Basic accuracy | < 0,1% ±2 Digit |
Temperature coefficient | 0.004%/K |
Transmitter supply | U0 approx. 24V, Ri approx. 150 Ω, max. 50 mA (max. 25 mA at 4 relay outputs) |
Display
Display scope | ± 9999(0) digits with suppression of leading zeroes |
Additional display | LED 2 digits, red, 7 mm (display for parameter and switching state) |
Output
Relay | Change-over contact < 250 V AC < 250 VA < 2A, < 300 V DC < 50 VA < 2 A |
Analog output | 0/4…20 mA working resistance ≤ 500 Ω; 0/2…10V working resistance > 500 Ω, No galvanic separation, output switches automatically (load-dependent) |
Accuracy | 0.1%; TK 0.01 %/K |
Conditions for use
Operation temperature | -20…+55 °C |
Auxiliary energy
Supply voltage | 230 V AC ± 10%; 115 V AC ± 10%; 24 V AC ± 10 % or 24 V DC ± 15% |
Power input | max. 3.5 VA |
Rated voltage | 250 V~ according to VDE 0110 between input/output/auxiliary voltage, Overvoltage Category III |
Test voltage | 4 kV= between input/output/auxiliary voltage |
CE conformity | EN55022, EN60555, IEC61000-4-3/4/5/11/13 |
Design configuration
Housing | Glassfibre-reinforced polyamide PA6-GF 15/15 for wall structures |
Dimensions | see dimensional drawing |
Weight | max. 450 g |
Connection | Spring-loaded clamps, 2 mm² single wire, 1.5 mm² single wire, AWG14 |
Type of protection | IP 65, clamps IP 20, contact protected according to BGV A3 |
Download Data Sheet: Digital Display for Signal Input DSA 1010
Ref: hengesbach.com
Another Article:
- Digital Display for Signal Input DSA 9648 Hengesbach
- Bamo TS 11 Temperature Probe with Pt 100 Ω Sensor
- Hengesbach Digital Temperature Transmitter TE 42
- Digital Tank Level Display DTA 1010 Hengesbach
- Hengesbach Pressure and Level Transmitter PZM Series 050D
- Hengesbach PZM/VRM 200/201 Pressure and Level Transmitter
- Flush-Mounted Pressure Transmitter VRM050D Series Hengesbach
- Flush-Mounted Pressure Transmitter TCF050D Hengesbach
- Hengesbach Pressure Measurement
- Pressure Transducer DMU 100 Series Hengesbach
- Conductive Level Sensor Type NKS 11 Hengesbach
- Hengesbach NC1 Level Module
- Hengesbach TE 32 Digital Temperature Transmitter
- Hengesbach Digital Temperature Transmitter TE 42
- Digitemp Single Color Thermometers
- TX-600N Data-Logging Thermometer
- 16 Event Liquid Crystal Thermometers – Thermax
- Cable Resistance Thermometer – Ephy Mess
- Hengesbach NKS 13 Conductive Level Sensor
- Flush-Mounted Pressure Transmitter TCF050D Hengesbach
- LEEG Pressure Transmitter, Sensor and Switch
- Flush-Mounted Pressure Transmitter VRM050D Series Hengesbach
- Hengesbach DM-73 Diaphragm Seals
- Hengesbach TE 32 Digital Temperature Transmitter
- D22 Pressure Transmitter Delta Mobrey