Kobold DRG Rotating Vane Flow Meter

Description

Kobold DRG Rotating Vane Flowmeters is used for measuring and monitoring low viscous liquids. Series DRG flow meters are working according to the well-known rotating vane principle. A magnet fitted in the vane and hermetically sealed from the medium transfers non-contacting the rotary motion to a Hall-effect sensor mounted in the housing.

The sensor converts the rotary motion which is proportional to the flow to a frequency signal. A series-connected electronics unit converts the signal to an analog output, limit contacts or display.

Kobold DRG Fields of Application

  • Cooling water monitoring
  • Agricultural machinery
  • PCB board industry
Kobold DRG L Rotating Vane Flowmeters
Kobold DRG L Rotating Vane Flowmeters
  • Measuring range: 0.5 – 12 … 10 – 140 l/min water
  • Connection: G ? … G 1, ? … 1″ NPT
  • Material: brass, stainless steel, polypropylene
  • pmax: 40 bar
  • tmax: 80°C
  • Accuracy: ±3 % of full scale
  • Pulse output, analogue output
  • Measuring range: 0.5 – 12 … 10 – 140 l/min water
  • Connection: G ? … G 1, ? … 1″ NPT
  • Material: brass, stainless steel, polypropylene
  • pmax: 40 bar
  • tmax: 80°C
  • Accuracy: ±3 % of full scale
  • Analogue output, digital indicator
Kobold DRG C Rotating Vane Flowmeters
Kobold DRG C Rotating Vane Flowmeters
  • Measuring range: 0.5 – 12 … 10 – 140 l/min water
  • Connection: G ? … G 1, ? … 1″ NPT
  • Material: brass, stainless steel, polypropylene
  • pmax: 40 bar
  • tmax: 80°C
  • Accuracy: ±3 % of full scale
  • Analogue output, contacts NPN / PNP, digital indicator

 

Kobold DRG AD1 Rotating Vane Flowmeters
Kobold DRG AD1 Rotating Vane Flowmeters
  • Measuring range: 0.5 – 12 … 10 – 140 l/min water
  • Connection: G ? … G 1, ? … 1″ NPT
  • Material: brass, stainless steel, polypropylene
  • pmax: 40 bar
  • tmax: 80°C
  • Accuracy: ±3 % of full scale
  • Pulse output, analogue output, contacts, digital indicator

 

Kobold DRG Rotating Vane Flowmeters
Kobold DRG Rotating Vane Flowmeters

 

  • Measuring range: 0.5 – 12 … 10 – 140 l/min water
  • Connection: G ? … G 1, ? … 1″ NPT
  • Material: brass, stainless steel, polypropylene
  • pmax: 40 bar
  • tmax: 80°C
  • Accuracy: ±3 % of full scale
  • Relays, analogue output, batcher, digital display

Kobold DRG Technical Details

  • Material combinations: see order details in datasheet
  • Max. operating pressure: see order details in datasheet
  • Max. temperature: see order details in datasheet
  • Measuring accuracy: ±3% of full scale
  • Electrical connection: plug connector DIN 43 650, plug connector M12x1
  • Pressure loss: max. 1 bar at max. range
  • Protection: IP 65

Electronics

Frequency output (…F300)

  • Power supply: 12-28 VDC
  • Power consumption: 10 mA
  • Pulse output: PNP, open collector max. 25 mA
  • Electrical connection: plug connector M12x1

Frequency output with frequency divider

  • Power supply: 24 VDC ±20%
  • Power consumption: 15 mA
  • Pulse output: PNP, open collector, max. 25 mA
  • Electrical connection: plug connector M12x1
  • Division ratio: 1… 1/128, factory set

Analogue output (Option plug-on display)

  • Power supply: 24 VDC ±20%
  • Output: 0-20 mA or 4-20 mA, 2-wire or 3-wire
  • Max. load: 500 ?
  • Electrical connection: plug connector M12x1 or DIN 43650
  • Option: plug-on display (with plug connector DIN 43650 and output 4-20 mA only), 2-wire

 Compact electronics

  • Display: 3-segment LED
  • Analogue output: (0)4…20 mA adjustable, max. 500 W
  • Switching outputs: 1 (2) semiconductor PNP or NPN factory set
  • Contact operation: N/C / N/O contact frequency programmable
  • Setting: with 2 buttons
  • Power supply: 24 VDC ±20%, 3-wire technology approx. 100 mA
  • Electrical connection: plug connector M12x1

Download Datasheet: Kobold DRG Rotating Vane Flowmeters