Burkert Type 6011 Plunger Valve 2/2 Way Direct-acting

Valve 6011 is a direct-acting plunger valve. The stopper and plunger guide tube are welded together to enhance pressure resistance and leak-tightness. Various seal material combinations are available depending on the application. A Bürkert-specific flange design (SFB) enables space-saving arrangement of valves on a manifold.

Push-in fittings can be selected for flexible hose connection. In combination with a cable plug in accordance with industry standard Form B or DIN EN 175301-803 Form C, the valves satisfy protection class IP65. This product can be combined with Cable Plug Type 2507 and Type 2516.

Features

  • Direct-acting and compact small-format valve with diameter of up to DN 2.4
  • Screwed coil system
  • Simple and quick flange or manifold installation
  • Quick coupling (push-in fitting) for plug-in hose connections

Specifications

Technical Data

Product properties

Dimensions Detailed information can be found in chapter “4. Dimensions” on page 5 of datasheet.
Material
Seal FKM
Body Standard version: Brass, polyamide (PA), stainless steel 1.4305
Analytical version: Brass, stainless steel 1.4305
Weight Ca. 125 g

Performance data

Duty cycle/single valve when mounted as a block on a manifold 100% continuous rating Intermittent operation 60% (30 min) or with 2 W coil (on request)
Circuit function A

Electrical data

Operating voltage
Standard version 24 V DC, 24 V/50 Hz, 110/230 V/50 Hz
Analytical version 24 V DC, 230 V/50 Hz
Voltage tolerance ±10%

Medium data

Medium
Standard version Technical vacuum, neutral gases and fluids (e.g. compressed air, water, hydraulic oil)
Neutral/aggressive medium that do not attack the body and seal materials
Analytical version
Viscosity Max. 21 mm²/s
Medium temperature -10…+100 °C

Approvals and certificates

Degree of protection IP65 with cable plug

Product connection

Port connection
Standard version M5, G ⅛, sub-base
Analytical version G ⅛, sub-base
Electrical connection To DIN EN 175 301-803 Form C for cable plug Type 2516 (see “5.4. Ordering chart accessories” on page 11 of datasheet)
To industry standard connector Form B for cable plug Type 2507 (see “5.4. Ordering chart accessories” on page 11 of datasheet)
Environment and installation
Installation position As required, preferably with actuator upright
Ambient temperature (max.) +55 °C
Installation instructions No oil, grease or silicones to be used as installation aids
Share