Description
H2Scan HY-ALERTA 2620 Explosion Proof Area Hydrogen Monitor provides hydrogen-specific leak detection and measurement for hydrogen concentrations as low as 4000 ppm and can be scaled to any concentration up to 5% hydrogen by volume, a range representing 10% to 125% of hydrogen’s low flammability limit.
The monitor is designed for either ceiling or wall mount. H2scan hydrogen monitor sensor technology has no cross-sensitivity to other combustible gases, thus eliminating false positive alarms and ensuring safety system reliability.
H2Scan HY-ALERTA 2620 Applications
- Battery Rooms
- H2 monitoring during lead acid battery charging
- Hydrogen Cooled Generators and Turbines
- Leak detection during operation
- Control Rooms / Analyzer Buildings
- Detection of potentially flammable H2 buildup in occupied areas
- Industrial Gas Supply and Hydrogen Production
- Leak detection around H2 storage facilities and pipes
- Laboratories
- General hydrogen safety monitoring
- Furnaces and Manufacturing
- Area monitoring for unburnt hydrogen
- Alternative Energy
- Hydrogen refueling station safety monitoring Fuel cell and electrolyzer leak monitoring
- Other Applications
- General area monitoring wherever there is a risk of hydrogen accumulation
- General area monitoring wherever there is a risk of hydrogen accumulation
H2Scan Explosion Proof Area Advantages
- Highly reliable
- Wide hydrogen-specific detection range
- Low life cycle cost
- Works in air, oxygen, or inert gas background
- Easy to install and operate
- Does not degrade over time
- Minimal maintenance required
- Non-consumable solid-state technology
- No cross-sensitivity to combustible gases
- Field-configurable settings
- Not vulnerable to poisoning like other detectors
- Will not saturate with exposure to hydrogen
H2Scan HY-ALERTA 2620 Performance
- Hydrogen Sensitivity Range: 0.4% to 5.0% hydrogen by volume, 10% to 125% hydrogen lower flammable limit
- Response Time: T90 < 60 sec
- Ingress Protection: IP64 capable
- Calibration Interval: 90 days
- Product Life Expectancy: 10 years
- Accuracy: ± (3% of reading + 0.2) percent hydrogen by volume
Interface Options
- Input Voltage Range: 90 VAC to 240 VAC
- Input Power: 15W
- Analog Outputs:
- Output Currents
– 4 mA to 20 mA
– 0 mA to 20 mA
– User-specific mA range
- Output Currents
- Serial Communication Options: RS232 or RS422
- Relay Contacts: Two programmable relays and one fault relay with both normally open (N.O.) and normally closed (N.C.) contacts:
– 5A/240VAC
– 5A/ 30 VDC
H2Scan HY-ALERTA 2620 Dimensions
- Width: 13.8 cm (5.4 in)
- Length: 19.2 cm (7.5 in)
- Depth: 13.0 cm (5.7 in)
Operating Conditions
- Operating Temperature Range: -20ºC to 55ºC
- Storage Temperature Range: -30ºC to 80ºC
- Operating Humidity: 0% to 95% RH (non-condensing)
- Calibration Background Gas: Air
Adapter Fittings
- 1/4 in. Tube for Calibration Gas Connection
Download: Datasheet
Other Article:
- H2Scan Technology
- Eltra Hydrogen Analyzer CHS 580
- H2Scan HY-ALERTA 2620 Explosion Proof Hydrogen Monitor
- H2Scan HY-ALERTA 600B Fixed Area Hydrogen Monitor
- H2Scan HY-ALERTA 1600 Intrinsically Proof Hydrogen Monitor
- Eska Double Stage Gas Pressure Regulators
- Roots Flow Meter
- Delta Mobrey Flow, Steam and Water, Conductivity Probe