Pressure and Level Transmitter TPF 200/201 Hengesbach

 

Pressure and Level Transmitter TPF 200/201

The TPF pressure transmitters are suitable for taking pressure and filling level measurements in pipelines and containers. The wide range of hygienic process connections enables use in all applications in the food and pharmaceutical industries.

The vacuum-proof measuring cell with stainless steel membrane works on the basis of the piezoresistive measuring principle The TPF pressure transmitters are designed to measure from -1/0…0.35 to -1/0…100bar. Special measuring ranges are also available on request. Given the nature of the design for long-term medium temperatures of up to 125°C / 200°C, CIP and SIP cleaning methods can be used on the transmitters. The high protection classes of IP67 and IP69K also mean that the devices can be safely cleaned on the outside with foam and a high-pressure cleaner and that moisture is reliably prevented from entering into the device.

Features:

  • High precision 0.05% fs, turn down 10, vacuum safe
  • Wide range of process connections for hygienic applications
  • Optional with hart®-protocol
  • Tank linearisation for standard tank shapes and special designs thanks to volumetric measurement
  • Diagnosis function for monitoring of devices
  • Copying of device parameters with easy transfer
  • Application strengths: measurement of content of pressurised tanks / vacuum measurements with high temperatures

Another Article:

Specification:

General details

Device type / measuring principle TPF 200/201/200H/201H: piezoresistive

Input

Measuring ranges TPF 200/201/200H/201H TPF 200/201/200H/201H
Standard nominal measuring ranges [bar] relative OP absolute OP
OP = overload protection [bar] 0…0.35 1
0…1 3 0…1 3
-1/0…2.5 8 0…2.5 8
Special measuring ranges  -1/0…5 15 0…5 15
-1/0…10 30 0…10 30
All measuring cells are vacuum-proof -1/0…30 90 0…30 90
-1/0…100 250 0…100 250
Setting the measuring ranges Via the keypad of the OPUSi display and operating module / via the integrated on-site display
Optional: via HART®
Setting ranges Start the measuring zero: 0…90% of the sensor’s nominal measuring span TD=10
Measuring span span: 10…100% of the sensor’s nominal measuring span
Burst pressure DIN16086 ≥ 4-fold measuring range

Output

Output signal 2-wire:   4…20mA with a test circuit connection in the device
Optional: 4…20mA HART®
Fault signal Optional: 3.8mA, 22mA, hold (i.e. holding the last value)
Current limitation 3.85mA and 21.5mA (normal operation)
Integration time Continuously selectable between 0 and 300s (setting time after a pressure leap)

Measuring accuracy

Reference conditions acc. to DIN IEC 770
Linearity, hysteresis and repeatability as per the limit point method DIN IEC 770 ≤ ± 0.05% of the sensor’s nominal measuring range
Activation time < 5s (the device will carry out a self-test.)
Setting time (without damping) < 200ms
Long-time drift ≤ 0.2% of the span per year
Thermal hysteresis ≤ ± 0.75% beginning of the measuring range / ≤ ± 0.8% end of the measuring range (VRM)
≤ ± 0.2% of the sensor’s nominal measuring range / 10K (-20… +80°C) from 4 bar (PZM)
≤ ± 0.3% of the sensor’s nominal measuring range / 10K (-20… +80°C) up to 0.6 bar (PZM)

Conditions of use

Installation position / calibration position Any position / standing vertically (position-dependent zero point displacement)
Medium temperature T1: -40…+125°C (140°C over one hour at the most)
T2: -40…+200°C (high-temperature version)
Ambient storage temperature Type 201/201H: -40…+85°C
Type 200/200H: -30…+75°C
(Below -20°C cable breakage might occur and the display’s function may be impaired.)
Protection class acc. to EN60529 IP 67 and IP 69K
Electromagnetic compatibility Sensitivity against interference: acc. to DIN IEC 61000-6-2
Interference radiation: acc. to DIN IEC 61000-6-4

Construction

Electrical connection – Standard: cable screw connection M16x1.5, nickel-plated brass, stainless steel available on request
– Optional: round plug-in connector M12x1, nickel-plated brass, stainless steel available on request
– Optional: angle plug acc. to EN 175301-803
– Optional: reference cable
Process connection – All standard front-mounted process connections and those that are commonly used by the manufacturer
– Membrane, flush-welded on the front, CrNiSt, other materials available on request

Download Data Sheet: Pressure and Level Transmitter TPF 200/201

Ref: hengesbach.com

Be the first to comment