Aquaread LeveLine Mini CTD Water Level

Aquaread LeveLine Mini CTD Water Level is a titanium water level, temperature, conductivity and salinity measuring sensor that has been specifically designed to bring conductivity and salinity measurements to your telemetric deployments.

The LeveLine-Mini-CTD is available in both absolute and gauge versions. If your chosen datalogger / telemetry device includes a built-in air pressure sensor, we recommend the absolute version as the logging device can utilise the air pressure reading for compensation. If an air pressure sensor is unavailable then the gauge version is best suited for telemetric logging.

Gauge sensors require vented cables and desiccant cartridges to remove any moisture from the vent to prevent blocking and inaccurate compensation.

Aquaread LeveLine Mini CTD Water Level Specifications

General

LEVELINE – (Abs & Gauge)LEVELINE – BAROLEVELINE- MINILeveLine-CTDLeveLine-Mini-CTD
Temperature rangesOperational: -20-80° C (-4-176° F)
Storage: -40-80° C (-40-176° F)
Compensated: -20-80° C (-4-176° F)
Operational: -20-80° C (-4-176° F)
Storage: -40-80° C (-40-176° F)
Compensated: -20-80° C (-4-176° F)
Operational: -20-80° C (-4-176° F)
Storage: -40-80° C (-40-176° F)
Compensated: -20-80° C (-4-176° F)
Operational: -20-80° C (-4-176° F)
Storage: -40-80° C (-40-176° F)
Compensated: -20-80° C (-4-176° F)
Operational: -20-80° C (-4-176° F)
Storage: -40-80° C (-40-176° F)
Compensated: -20-80° C (-4-176° F)
Diameter22.2mm (0.875 in)22.2mm (0.875 in)22.2mm (0.875 in)22mm22mm
Length186mm (7.32 in)186mm (7.32 in)87mm (3.43 in)260mm146mm
Weight150g (5.3oz)160g (5.6oz)120g (4.2oz)250g210g
MaterialsTitanium body, Delrin nose coneStainless Steel body, Delrin nose coneStainless Steel body, Delrin nose coneTitanium body, Delrin nose coneTitanium body, Delrin nose cone
Output optionsModbus/RS485, SDI-12, Aquaread proprietaryModbus/RS485, SDI-12, Aquaread proprietaryModbus/RS485, SDI-12, Aquaread proprietaryModbus/RS485, SDI-12, Aquaread proprietaryModbus/RS485, SDI-12, Aquaread proprietary
Battery type & life3.6V lithium; up to 10 years (see note 1)3.6V lithium; up to 10 years (see note 1)N/A3.6V lithium; up to 10 years (see note 1)N/A
External power6 – 30 VDC6 – 30 VDC6 – 30 VDC6 – 24 VDC6 – 24 VDC

Memory

LEVELINE – (Abs & Gauge)LEVELINE – BAROLEVELINE- MINILeveLine-CTDLeveLine-Mini-CTD
Size8.0 MB2.0 MBN/A8.0 MBN/A
Data records500,000150,000N/A500,000N/A
Log typesLinear, Event & User-Selectable
Schedule with Future Start, Future Stop,
Deploy Start and Real Time View
Linear, Event & User-Selectable
Schedule with Future Start, Future Stop,
Deploy Start and Real Time View
N/ALinear, Event & User-Selectable Schedule with Future
Start, Future Stop, Deploy Start and Real Time View
N/A
Fastest logging rate & Modbus rate10 per second1 per minute (logging)
5 per second (Modbus)
10 per second (Modbus Rate)1 per second1 per second
Fastest SDI-12 output rate1 per second1 per second1 per second1 per second1 per second
Real-time clockAccurate to 1 second/24-hr period (± 6 minutes/year)Accurate to 1 second/24-hr period (± 6 minutes/year)N/AAccurate to 1 second/24-hr period (± 6 minutes/year)N/A

Sensor

LEVELINE – (Abs & Gauge)LEVELINE – BAROLEVELINE- MINILeveLine-CTDLeveLine-Mini-CTD
Type / MaterialPiezoresistive; ceramicPiezoresistive; ceramicPiezoresistive; ceramicPiezoresistive; ceramicPiezoresistive; ceramic
Range (Absolute)10.0m (32.8 ft), 20.0m (65.6 ft), 50.0m (164 ft), 100m (326 ft), 200m (656 ft)0 to 16.7 psi; 0 to 1.15 bar10.0m (32.8 ft), 20.0m (65.6 ft), 50.0m (164 ft), 100m (326 ft), 200m (656 ft)10.0M (32.8 ft), 50.0M (164 ft), 20.0M (65.6 ft), 100M (326 ft)10.0M (32.8 ft), 50.0M (164 ft), 20.0M (65.6 ft), 100M (326 ft)
Range (Gauge)10.0m (32.8 ft), 20.0m (65.6 ft), 50.0m (164 ft), 100m (326 ft), 200m (656 ft)N/AN/A10.0M (32.8 ft), 50.0M (164 ft), 20.0M (65.6 ft), 100M (326 ft)10.0M (32.8 ft), 50.0M (164 ft), 20.0M (65.6 ft), 100M (326 ft)
Maximum pressureMax 2x range, Burst 2.5x rangeMax 2x range, Burst 2.5x rangeMax 2x range, Burst 2.5x rangeMax 2x range, Burst 2.5x rangeMax 2x range, Burst 2.5x range
Accuracy (FS) (see note 3)±0.05% FS±0.1% FS±0.05% FS±0.05% FS±0.05% FS
Accuracy (FS) (See note 2)±0.1% FS±0.2% FS±0.1% FS±0.1% FS±0.1% FS
Resolution0.005% FS or 1mm whichever is greater0.1mb0.005% FS or 1mm whichever is greater0.002% FS or 1mm whichever is greater0.002% FS or 1mm whichever is greater
Units of measurePressure: psi, kPa, bar, mbar, mmHg, inHg, cmH2O, inH2O, Level: in, ft, mm, cm, mPressure: psi, kPa, bar, mbar, mmHg, inHg, cmH2O, inH2OPressure: psi, kPa, bar, mbar, mmHg, inHg, cmH2O, inH2O, Level: in, ft, mm, cm, mPressure: mbar (psi, kPa, bar, mbar, mmHg, inHg, cmH2O, inH2O, Level: in, ft, mm, cm and m available in LeveLinkPressure: mbar (psi, kPa, bar, mbar, mmHg, inHg, cmH2O, inH2O, Level: in, ft, mm, cm and m available in LeveLink

Electrical Conductivity

LEVELINE – (Abs & Gauge)LEVELINE – BAROLEVELINE- MINILeveLine-CTDLeveLine-Mini-CTD
RangeN/AN/AN/A0 – 200mS/cm (0 – 200,000µS/cm)0 – 200mS/cm (0 – 200,000µS/cm)
ResolutionN/AN/AN/A1µS1µS
AccuracyN/AN/AN/A± 1% reading or ±1µS whichever is greater (see note 5)± 1% reading or ±1µS whichever is greater (see note 5)

Salinity (note 4)

LEVELINE – (Abs & Gauge)LEVELINE – BAROLEVELINE- MINILeveLine-CTDLeveLine-Mini-CTD
RangeN/AN/AN/A0 – 70 PSU / 0 – 70 ppt (g/Kg)0 – 70 PSU / 0 – 70 ppt (g/Kg)
ResolutionN/AN/AN/A0.01PSU / 0.01 ppt0.01PSU / 0.01 ppt
AccuracyN/AN/AN/A±1% reading or ± 0.1 unit if greater±1% reading or ± 0.1 unit if greater

Temperature Sensor

LEVELINE – (Abs & Gauge)LEVELINE – BAROLEVELINE- MINILeveLine-CTDLeveLine-Mini-CTD
Accuracy Resolution±0.1° C
0.01° C
±0.1° C
0.01° C
±0.1° C
0.01° C
±0.1° C; 0.01° C±0.1° C; 0.01° C
Units of measureCelsiusCelsiusCelsiusCelsius (fahrenheit available in LeveLink)Celsius (fahrenheit available in LeveLink)

Warranty

LEVELINE – (Abs & Gauge)LEVELINE – BAROLEVELINE- MINILeveLine-CTDLeveLine-Mini-CTD
StandardN/AN/AN/A2 years2 years
ExtendedN/AN/AN/AOptions AvailableOptions Available

Notes: 1) Dependent on logging rate. 2) Across factory-calibrated pressure range at a constant temperature. 3) Across factory-calibrated pressure and temperature ranges. 4) Readings calculated from EC and temperature values. 5) At the calibration point at 25°C

Reference : aquaread.com