Aquaread LeveLine Mini CTD Water Level is a titanium water level, temperature, conductivity and salinity measuring sensor that has been specifically designed to bring conductivity and salinity measurements to your telemetric deployments.
The LeveLine-Mini-CTD is available in both absolute and gauge versions. If your chosen datalogger / telemetry device includes a built-in air pressure sensor, we recommend the absolute version as the logging device can utilise the air pressure reading for compensation. If an air pressure sensor is unavailable then the gauge version is best suited for telemetric logging.
Gauge sensors require vented cables and desiccant cartridges to remove any moisture from the vent to prevent blocking and inaccurate compensation.
Aquaread LeveLine Mini CTD Water Level Specifications
General
LEVELINE – (Abs & Gauge) | LEVELINE – BARO | LEVELINE- MINI | LeveLine-CTD | LeveLine-Mini-CTD | |
Temperature ranges | Operational: -20-80° C (-4-176° F) Storage: -40-80° C (-40-176° F) Compensated: -20-80° C (-4-176° F) |
Operational: -20-80° C (-4-176° F) Storage: -40-80° C (-40-176° F) Compensated: -20-80° C (-4-176° F) |
Operational: -20-80° C (-4-176° F) Storage: -40-80° C (-40-176° F) Compensated: -20-80° C (-4-176° F) |
Operational: -20-80° C (-4-176° F) Storage: -40-80° C (-40-176° F) Compensated: -20-80° C (-4-176° F) |
Operational: -20-80° C (-4-176° F) Storage: -40-80° C (-40-176° F) Compensated: -20-80° C (-4-176° F) |
Diameter | 22.2mm (0.875 in) | 22.2mm (0.875 in) | 22.2mm (0.875 in) | 22mm | 22mm |
Length | 186mm (7.32 in) | 186mm (7.32 in) | 87mm (3.43 in) | 260mm | 146mm |
Weight | 150g (5.3oz) | 160g (5.6oz) | 120g (4.2oz) | 250g | 210g |
Materials | Titanium body, Delrin nose cone | Stainless Steel body, Delrin nose cone | Stainless Steel body, Delrin nose cone | Titanium body, Delrin nose cone | Titanium body, Delrin nose cone |
Output options | Modbus/RS485, SDI-12, Aquaread proprietary | Modbus/RS485, SDI-12, Aquaread proprietary | Modbus/RS485, SDI-12, Aquaread proprietary | Modbus/RS485, SDI-12, Aquaread proprietary | Modbus/RS485, SDI-12, Aquaread proprietary |
Battery type & life | 3.6V lithium; up to 10 years (see note 1) | 3.6V lithium; up to 10 years (see note 1) | N/A | 3.6V lithium; up to 10 years (see note 1) | N/A |
External power | 6 – 30 VDC | 6 – 30 VDC | 6 – 30 VDC | 6 – 24 VDC | 6 – 24 VDC |
Memory
LEVELINE – (Abs & Gauge) | LEVELINE – BARO | LEVELINE- MINI | LeveLine-CTD | LeveLine-Mini-CTD | |
Size | 8.0 MB | 2.0 MB | N/A | 8.0 MB | N/A |
Data records | 500,000 | 150,000 | N/A | 500,000 | N/A |
Log types | Linear, Event & User-Selectable Schedule with Future Start, Future Stop, Deploy Start and Real Time View |
Linear, Event & User-Selectable Schedule with Future Start, Future Stop, Deploy Start and Real Time View |
N/A | Linear, Event & User-Selectable Schedule with Future Start, Future Stop, Deploy Start and Real Time View |
N/A |
Fastest logging rate & Modbus rate | 10 per second | 1 per minute (logging) 5 per second (Modbus) |
10 per second (Modbus Rate) | 1 per second | 1 per second |
Fastest SDI-12 output rate | 1 per second | 1 per second | 1 per second | 1 per second | 1 per second |
Real-time clock | Accurate to 1 second/24-hr period (± 6 minutes/year) | Accurate to 1 second/24-hr period (± 6 minutes/year) | N/A | Accurate to 1 second/24-hr period (± 6 minutes/year) | N/A |
Another Article: |
Sensor
LEVELINE – (Abs & Gauge) | LEVELINE – BARO | LEVELINE- MINI | LeveLine-CTD | LeveLine-Mini-CTD | |
Type / Material | Piezoresistive; ceramic | Piezoresistive; ceramic | Piezoresistive; ceramic | Piezoresistive; ceramic | Piezoresistive; ceramic |
Range (Absolute) | 10.0m (32.8 ft), 20.0m (65.6 ft), 50.0m (164 ft), 100m (326 ft), 200m (656 ft) | 0 to 16.7 psi; 0 to 1.15 bar | 10.0m (32.8 ft), 20.0m (65.6 ft), 50.0m (164 ft), 100m (326 ft), 200m (656 ft) | 10.0M (32.8 ft), 50.0M (164 ft), 20.0M (65.6 ft), 100M (326 ft) | 10.0M (32.8 ft), 50.0M (164 ft), 20.0M (65.6 ft), 100M (326 ft) |
Range (Gauge) | 10.0m (32.8 ft), 20.0m (65.6 ft), 50.0m (164 ft), 100m (326 ft), 200m (656 ft) | N/A | N/A | 10.0M (32.8 ft), 50.0M (164 ft), 20.0M (65.6 ft), 100M (326 ft) | 10.0M (32.8 ft), 50.0M (164 ft), 20.0M (65.6 ft), 100M (326 ft) |
Maximum pressure | Max 2x range, Burst 2.5x range | Max 2x range, Burst 2.5x range | Max 2x range, Burst 2.5x range | Max 2x range, Burst 2.5x range | Max 2x range, Burst 2.5x range |
Accuracy (FS) (see note 3) | ±0.05% FS | ±0.1% FS | ±0.05% FS | ±0.05% FS | ±0.05% FS |
Accuracy (FS) (See note 2) | ±0.1% FS | ±0.2% FS | ±0.1% FS | ±0.1% FS | ±0.1% FS |
Resolution | 0.005% FS or 1mm whichever is greater | 0.1mb | 0.005% FS or 1mm whichever is greater | 0.002% FS or 1mm whichever is greater | 0.002% FS or 1mm whichever is greater |
Units of measure | Pressure: psi, kPa, bar, mbar, mmHg, inHg, cmH2O, inH2O, Level: in, ft, mm, cm, m | Pressure: psi, kPa, bar, mbar, mmHg, inHg, cmH2O, inH2O | Pressure: psi, kPa, bar, mbar, mmHg, inHg, cmH2O, inH2O, Level: in, ft, mm, cm, m | Pressure: mbar (psi, kPa, bar, mbar, mmHg, inHg, cmH2O, inH2O, Level: in, ft, mm, cm and m available in LeveLink | Pressure: mbar (psi, kPa, bar, mbar, mmHg, inHg, cmH2O, inH2O, Level: in, ft, mm, cm and m available in LeveLink |
Electrical Conductivity
LEVELINE – (Abs & Gauge) | LEVELINE – BARO | LEVELINE- MINI | LeveLine-CTD | LeveLine-Mini-CTD | |
Range | N/A | N/A | N/A | 0 – 200mS/cm (0 – 200,000µS/cm) | 0 – 200mS/cm (0 – 200,000µS/cm) |
Resolution | N/A | N/A | N/A | 1µS | 1µS |
Accuracy | N/A | N/A | N/A | ± 1% reading or ±1µS whichever is greater (see note 5) | ± 1% reading or ±1µS whichever is greater (see note 5) |
Salinity (note 4)
LEVELINE – (Abs & Gauge) | LEVELINE – BARO | LEVELINE- MINI | LeveLine-CTD | LeveLine-Mini-CTD | |
Range | N/A | N/A | N/A | 0 – 70 PSU / 0 – 70 ppt (g/Kg) | 0 – 70 PSU / 0 – 70 ppt (g/Kg) |
Resolution | N/A | N/A | N/A | 0.01PSU / 0.01 ppt | 0.01PSU / 0.01 ppt |
Accuracy | N/A | N/A | N/A | ±1% reading or ± 0.1 unit if greater | ±1% reading or ± 0.1 unit if greater |
Temperature Sensor
LEVELINE – (Abs & Gauge) | LEVELINE – BARO | LEVELINE- MINI | LeveLine-CTD | LeveLine-Mini-CTD | |
Accuracy Resolution | ±0.1° C 0.01° C |
±0.1° C 0.01° C |
±0.1° C 0.01° C |
±0.1° C; 0.01° C | ±0.1° C; 0.01° C |
Units of measure | Celsius | Celsius | Celsius | Celsius (fahrenheit available in LeveLink) | Celsius (fahrenheit available in LeveLink) |
Warranty
LEVELINE – (Abs & Gauge) | LEVELINE – BARO | LEVELINE- MINI | LeveLine-CTD | LeveLine-Mini-CTD | |
Standard | N/A | N/A | N/A | 2 years | 2 years |
Extended | N/A | N/A | N/A | Options Available | Options Available |
Notes: 1) Dependent on logging rate. 2) Across factory-calibrated pressure range at a constant temperature. 3) Across factory-calibrated pressure and temperature ranges. 4) Readings calculated from EC and temperature values. 5) At the calibration point at 25°C