Alia Ultrasonic Flow Meter is a bit of product from alia, and they’ve 3 different installation of ultrasonic flow meter series, there a clamp-on, fixed mount, and portable. Based on microprocessor and programmable flow measurement techniques the process flow can be accurately measured without interrupting the flow and with low installation costs.
Alia AUF770 Ultrasonic flow meter
The AUF770 Series sanitary type ultrasonic flowmeter adopts materials and new processes that meet the sanitary requirements of food industry. It uses stainless steel housing and clamp connection, which is easy to disassembly and cleaning. And it can effectively prevent pollution during using and the residues in the measuring tube.
AUF770 can be widely used in food production process such as mineral water, soy sauce, jam, beer, juice, rice wine and milk, as well as in the fields of sanitation and chemical industry.
Feature :
- Clamp type sensor, non-contact measurement.
- 4 line LCD display with flowrate, totalizer & signal condition.
- Stores up 64 Day / Month / Year Totalizer daily value.
- Batch control function.
- Wide range velocities of 0.01~+/-32 m/s.
- High accuracy of +/-0.5% of reading.
- IDF Tri-Clamp or Union screw Connection.
- Data logger function, include the date, totalizer, signal condition, etc.
Specification
Measuring Principle | : | Transit time difference |
Pipe Size | : | 25-200 mm (1″-8″) |
Body Material | | |
Measuring Tube | : | S.S. 304 / S.S. 316 / S.S. 316L |
Housing | : | S.S. 304 |
Separation Box | : | Aluminum alloy |
Process Connection | : | IDF Tri-Clamp or Screw Union |
Tri-Clamp Standard | : | HAB / DIN32676 / ISO2852 |
Screw Union Standard | : | DIN11851 |
Max. Pressure | : | 1.0 MPa |
Max. Temperature | : | -40~110 °C (Standard) |
| : | -40~160 °C (Optional) |
Display | : | 4 Line LCD with illumination |
Flowrate | : | 5 Digit with decimal point |
Totalizer | : | 8 Digit, Forward, Reverse & Net values. |
Engineer Unit | : | m3, Liter, US Gallon, Imperial Gallon, |
| | Million Gallon, Cubic Feet, US Barrels, |
| | Imperial Barrels, Oil Barrel |
Time Unit | : | Second, Minute, Hour, Day |
Other | : | Velocity, Date, Time, Signal condition. |
Accuracy | : | +/-0.5% of reading (0.5-30 m/s) |
Repeatability | : | +/-0.2% of reading |
Transmitter Mounting | : | Wall mounting |
Keypad | : | 16 Key with tactile action |
Response Time | : | <1 s |
Resolution | : | 0.0001 m/s |
Flow Velocity | : | 0.01~+/-32 m/s |
Ambient Temperature | : | -20~50 °C |
Max. Cable Length | : | 300 m |
Power Consumption | : | <2 W |
Power Supply | : | 85-265 VAC 50/60 Hz or 8-36 VDC |
Data Storage | : | Operation parameters and totalizer |
| | figures are stored by EEPROM for more |
| | than 10 years |
Current Output | : | 4-20 mA / 0-20 mA / 20-4-20 mA |
Pulse Output | : | 1-9999 Hz |
Data Logger | : | SD card (16 G) Data-Logger |
| | (Flowrate, totalizer, time, Energy, etc.) |
Recording Capability | : | 4 Years (1 columns / 1 seconds) |
| : | 240 Years (1 columns / 1 minutes) |
Alarm | : | High / Low with buzzer |
| : | 30 VDC 1 A / 125 VAC 0.5 A |
Communication | : | RS485 (MODBUS) |
Protection Class | | |
Converter | : | IP65 |
Sensor | : | IP67 |
Alia AUF610 Portable Ultrasonic Flow Meter
The AUF610 Series is a Handheld transit-time ultrasonic flowmeter with clamp-on transducers for non-invasive liquid measurement. Based on microprocessor and programmable flow measurement techniques the process flow can be accurately measured without interrupting the flow and with low installation costs.
Features
- 4 line LCD to display flow rate, totalizer signal condition, etc.
- The flowmeter is designed in high accuracy +/-1.0%.
- Small-sized (260 * 100 * 35 mm) light-weight (600 g).
- Wide range, Velocities (0.01~+/-32 m/s).
- Ni-MH Battery lasts for over 10 hours of continuous operation.
- Maximum temperature of 160 oC.
- Transducers for pipes size from 15-6000 mm (1/2″-240″).
- A built-in magnet in transducers, no need for a steady tool on metal pipe.
- Data logger which records flowrate, date, total flow, signal condition, etc.
- Response time less than 1 second.
Specification
Measuring Principle | : | Transit time difference |
Pipe Size | : | S Type: 15-100 mm (1/2″-4″) |
| : | M Type: 50-1000 mm (2″-40″) |
| : | L Type: 300-6000 mm (12″-240″) |
| : | HS Type: 15-100 mm (1/2″-4″) |
| : | HM Type: 50-1000 mm (2″-40″) |
Pipe Material | : | Cast Iron, Stainless Steel, Ductile Iron |
| | Copper, PVC, Aluminum, Asbestos |
| | Fiberglass etc. |
Liner Material | : | Tar Epoxy, Rubber, Mortar, Polypropylene, |
| | Polystyrol, Polystyrene, Polyester, Ebonite, |
| | Polyethylene, Teflon etc. |
Display | : | 4 Line LCD with illumination |
Flowrate | : | 5 Digit with decimal point |
Totalizer | : | 8 Digit, Forward, Reverse & Net values |
Engineer Unit | : | m3, Liter, US Gallon, Imperial Gallon, |
| | Million Gallon, Cubic Feet, US Barrels, |
| | Imperial Barrels, Oil Barrel |
Time Unit | : | Second, Minute, Hour, Day |
Other | : | Velocity, Date, Time, Signal condition |
Accuracy | : | +/-1%~+/-2% value of reading (0.5-30 m/s) |
| : | +/-0.5% value of reading (Online calibration) |
Repeatability | : | +/-0.2% value of reading |
Keypad | : | 18 Key with tactile action |
Response Time | : | Less than 1 second |
Flow Velocity | : | 0.01~+/-32 m/s |
Resolution | : | 0.0001 m/s |
Ambient Temperature | : | -40~60 °C |
Ambient Humidity | : | 90% RH or Less |
Built-in Battery | : | Ni-MH Battery |
Operation Time | : | >10 Hours |
Charger | : | 90-260 VAC 50/60 Hz, 8-12 h charging |
Data Storage | : | Operation parameters and totalizer |
| | figures are stored by EEPROM for more |
| | than 10 years |
Data Logger | : | Limitless overwriting in 64 columns |
| | (Flowrate, totalizer, time, date included) |
Alarm | : | High / Low with buzzer |
Power Consumption | : | Less than 2W |
Dimensions | : | 206 * 100 * 35 mm |
Weight | : | 0.6 kg |
Protection Class | | |
Converter | : | IP65 |
Sensor | : | IP65 (Standard) |
| : | IP68 (Submersible) |
Alia AUF760 Ultrasonic Flow Meter
The AUF760 Series is a fixed mounted, transit-time ultrasonic flowmeter. It features factory mounted transducers that allow it to flow lab calibrated reducing or eliminating the random or bias error that can be present in clamp-on style transducer mounting. The meter ensures an accurate, non-invasive measurement of clean homogeneous liquids process.
Features
- 4 line LCD display with flowrate, totalizer & signal condition.
- Stores up 64 Day / Month / Year Totalizer daily value.
- Batch control function.
- Wide range velocities of 0.01~+/- 32 m/s.
- Pipe size from 100-1000 mm.
- High accuracy of +/-1% of reading.
- Data logger function, include the date, totalizer, signal condition, etc.
- Response time less than 1 second
Alia AUF750 Clamp-on Ultrasonic Flow Meter
The AUF750 Series is a fixed mounted, transit-time ultrasonic Flowmeter. It features clamp-on style transducers for non-invasive measurement of clean homogeneous liquid processes. This user-friendly microprocessor-based, field programmable flowmeter ensures that the flow of existing processes can be performed without interrupting the flow and has very low installation costs.
Features
- 4 line LCD display with flowrate, totalizer & signal condition.
- Stores up 64 Day / Month / Year Totalizer daily value.
- Batch control function.
- Wide range velocities of 0.01~+/- 32 m/s.
- Transducers for pipe size from 15-6000 mm.
- High accuracy of +/-0.5% of reading.
- A built-in magnet in transducers, no need for a steady tool on metal pipe.
- Data logger function, include the date, totalizer, signal condition, etc.
- Response time less than 1 second.
Specification
Measuring Principle | : | Transit time difference |
Pipe Size | : | 100-1000 mm |
| : | 4″-40″ |
Material | : | Carbon Steel / Stainless Steel 304 |
| : | Stainless Steel 316 |
Process Connection | : | Flange |
Flange Type | : | JIS 7.5K / JIS 10K / JIS 20K / JIS 40K |
| | ANSI 150# / ANSI 300# / ANSI 600# |
| | DIN PN10 / PN16 / PN25 / PN40 |
Max. Pressure | : | 40 kgf/cm2 |
Process Temperature | : | -20~110 °C |
Display | : | 4 Line LCD with illumination. |
Flowrate | : | 5 Digit with decimal point |
Totalizer | : | 8 Digit, Forward, Reverse & Net values. |
Engineer Unit | : | m3, Liter, US Gallon, Imperial Gallon, |
| | Million Gallon, Cubic Feet, US Barrels, |
| | Imperial Barrels, Oil Barrel |
Time Unit | : | Second, Minute, Hour, Day |
Other | : | Velocity, Date, Time, Signal condition |
Accuracy | : | +/-1.0% of reading |
Repeatability | : | +/-0.2% of reading |
Response Time | : | Less than 1 second |
Mounting | : | Wall mounting |
Keypad | : | 16 Key with tactile action |
Flow Velocity | : | 0.01~+/-32 m/s |
Resolution | : | 0.0001 m/s |
Ambient Temperature | : | -20~50 °C |
Max. Cable Length | : | 300 m |
Power Consumption | : | Less than 2 W |
Power Supply | : | 85-265 VAC 50/60 Hz or 8-36 VDC |
Data Storage | : | Operation parameters and totalization |
| | figures are stored by EEPROM for more |
| | than 10 years |
Current Output | : | 4-20 mA or 0-20 mA or 20-4-20 mA |
Pulse Output | : | 1-9999 Hz |
Data Logger | : | SD card (16 G) Data-Logger |
| | (Flowrate, totalizer, time, Energy,etc.) |
Recording Capability | : | 4 Years (1 columns / 1 seconds) |
| : | 240 Years (1 columns / 1 minutes) |
Alarm | : | High / Low with buzzer |
| : | 30 VDC 1 A / 125 VAC 0.5 A |
Communication | : | RS485 (MODBUS) |
Dimension | : | 235 * 205 * 95 mm |
Weight | : | 1.5 kg (Converter) |
Protection Class | | |
Converter | : | IP65 |
Sensor | : | IP68 (Submersible) |
Alia AUF790 Ultrasonic Open Channel Flow Meter
The AUF790 Series is a fixed mounted, open channel ultrasonic flowmeter, with clamp-on transducer used for non-invasive measurement. Our microprocessor based, user friendly, field programmable flow measurement technique allows no interruption of the process flow and has low installation costs.
Features
- 4 line LCD display with flowrate, totalizer & Level condition
- V-notch, rectangular with and without end contractions, Cipolletti
- Parshall, Palmer-Bowlus, Leopold-Lagco, trapezoidal, H
- A sampler relay will signal your sampler to collect flow proportion
- High accuracy of +/-0.25% of Full Scale
- Non-contact flow measurement
- Exclusive sensor for open channel flow
- Response time less than 1 second
Specification
Measuring Principle | : | Ultrasonic Sound |
Measuring Range | | |
Level | : | 0-3 Meter |
Flow Rate | : | 0-120000 m3/s |
Accuracy | : | +/-0.25% of Full Scale |
Repeatability | : | +/-0.1% of reading |
Material | | |
Ultrasonic Tube | : | ABS |
Sensor Head | : | Polyurethane (Standard) / ETFE / PTFE |
Housing | : | ABS (Remote Version) |
| : | Low copper cast aluminum alloy with |
| | polyurethane (Compact Version) |
Display | : | 4 Line LCD with illumination |
Flowrate | : | 9 Digits with decimal point |
Totalizer | : | 9 Digits |
Level | : | 4 Digits |
Flow Engineer Unit | : | m3, Liter |
Level | : | Meter / Feet |
Time Unit | : | Second, Hour |
Other | : | Signal condition |
Formula | : | V-notch, Parshall, Palmer-Bowlus |
| : | Rectangular, Cipolletti, Leopold-Lagco |
Sensor Frequency | : | 40 kHz / 1 kHz |
Temp Compensation | : | Built-in to compensate over temperature |
| | range |
Low Level Cutoff | : | 0.000-1.000 Meter |
Dead Band | : | 0.35 m Max. |
Bean Angle | : |  |
Keypad | : | 4 Key with tactile action |
Response Time | : | Less than 1 second |
Ambient Temperature | : | -20~60 °C |
Mounting | : | G2″ (Standard) / Flange end (Optional) |
Max. Cable Length | : | 50 m |
Power Consumption | : | Less than 3 W |
Power Supply | : | 90-260 VAC, 50/60 Hz (4 wires) |
| : | 18-36 VDC (4 wires) |
Data Storage | : | Operation parameters and totalization |
| | date are stored by EEPROM for more |
| | than 10 years |
Output | : | 4-20 mA |
Load | : | Rohm= (VDC-12) * 50 W |
Alarm | : | High / Low / High-High / Low-Low |
Communication | : | RS485 (MODBUS) |
Dimensions | | |
Compact | : | 130 mm (W) * 230 mm (H) * 180 mm (D) |
Remote | : | 183.5 mm (W) * 218 mm (H) * 125.5 mm (D) |
Weight | : | 3.5 kg (Compact), 2.2 kg (Remote) |
Enclosure | : | IP65 (ABS) / IP67 (Aluminum Alloy) |
| : | Explosion Proof, Ex d (ia) IIB T4 |
Source : alia-inc.com