Description

Flexim Fluxus F401 is the ideal flow meter for long-term measurement campaigns in the field. Depending on the programmed measurement interval the FLUXUS F401 can operate autonomously for several months.

This makes it suitable for leak detection campaigns and hydraulic studies, where regular measurements are needed over a longer period of time.

The clamp-on ultrasonic system has been designed specially to meet the needs of the water and wastewater industries. The FLUXUS F401 is installed without process interruption and the installation can be completed within a few minutes

Thereafter, it delivers accurate and highly repeatable measurements that are not affected by drift. Due to its excellent low flow capability (down to 0.01 m/s), the FLUXUS F401 is ideally suited for monitoring drinking water networks, in which low flow velocities are common.

The strong signal output and the noise suppression technology make it possible to use the FLUXUS F401 on very large pipes and challenging materials: Old and rusty steel, badly manufactured GRP or even armored concrete pipes (independent of lining and build-up inside the pipe) are not a metering challenge to the FLUXUS F401.

All parts of the FLUXUS F401 have been designed to ensure utmost robustness for regular heavy-duty use in rough conditions. The metal sheathing of the transducer cable ends protects them against strong bending or cuts and ensures tangle-free operation.

The six-meter cable length of the IP68 transducers allows for the installation of the transducers even in deep manholes, whereby the transmitter can be placed in the upper part of the manhole. The transmitter is housed in a robust case and has IP67 protection.

All this makes the FLUXUS F401 the ideal companion for the daily work of water suppliers, hydrologists, and engineering offices.

Flexim Fluxus F401 Applications

  • Temporary measurements in the water and wastewater industry
  • Leakage detection
  • Water loss balancing
  • Accuracy verification of permanently installed flowmeters
  • Monitoring of pumping tests

Specification

Measurement accuracy±2.0 % of reading ±0,01 m/s
Repeatability0.25 % of reading ±0,01 m/s
Flow velocity range0,01 … 25 m/s
Pipe diameter range40 mm … 3000 mm
Outputs1x Current, 1x Binary
Communication InterfaceRS232 / USB (with adapter)
Fluidwater with <6% gaseous or solid content by volume
Power Supply100…230 V/50…60 Hz (power supply unit
12 V DC (socket at the transmitter)
integrated battery
Physical Quantitiesvolumetric flow rate, mass flow rate, flow velocity
Totalizervolume, mass
Operating TemperatureTransmitter: -10 °C … 50 °C
Transducer: -40 °C … 100 °C
Degree of protectionTransmitter: IP67 (when closed), IP65 (when open)
Transducer: IP68