Harton anlagentechnik gmbh

Why Harton?

Our company looks back on a long tradition in which, since the beginning, the idea of innovation has always been in the foreground. An extensive delivery program offers our customers high-grade, constantly controlled quality, which is carefully produced on the basis of the latest technologies and the most advanced scientific findings.

Main Focus

Pumps, for aggressive and abrasive media, with magnetic coupling, sealless-leakfree, numerous material combinations, plastics, steel, stainless steel, special steel for various industrial applications, chemicals, food centrifugal pumps, diaphragm pumps pneumatically and electrically driven, gear pumps, internal gear pumps, eccentric screw pumps metering pumps, as piston and diaphragm pumps, metering systems, peristaltic pumps OEM designs, containers, apparatus, heat exchangers, focus on stainless steel.

Harton anlagentechnik gmbh
Pumps  Harton anlagentechnik gmbh

Centrifugal Pumps

We provide the right pump for each application. For use in the chemical industry, environmental engineering, analysis technology, food technology and many other areas. You can choose from a wide range of products, of different types of pumps and materials.

Harton anlagentechnik gmbh
Centrifugal Pumps Harton

Centrifugal pumps with magnetic coupling

Centrifugal pumps with magnetic coupling are completely maintenance-free thanks to the exclusive use of static seals. In contrast to conventional centrifugal pumps with mechanical seal or shaft seal, centrifugal pumps with magnetic coupling are permanently protected against leakage. The power transmission from the motor to the pump head is done magnetically. The motor drives the outer magnet, which passes through its rotational motion by the isolation shell of the magnetic head located in the pump. The isolation shell located between the magnets is thus the barrier that separates the medium securely from the outside atmosphere.

Centrifugal pumps with shaft seal: The rotary motion and power from the engine must be transmitted to the pump impeller, without the pumped liquid leaking from the pump head. The separation between the pumped medium and environment takes place on the drive shaft. The seal may be executed as a shaft seal or mechanical seal. Shaft seals must be checked regularly for leaks. The safety and lifetime of these gaskets is extremely inferior to that of magnetic couplings.

Pump in block design: The pump head is mounted directly on the engine. The extended motor shaft drives the impeller directly or via a rigid coupling.

Also Read : Sirco Mechanical Instruments

Positive Displacement Pumps

Positive displacement pumps are divided into two categories reciprocating pumps and rotary pumps. Positive displacement pumps are characterized by an almost constant flow with fluctuating back pressure.

A back-flow of the medium during standstill of the pump is prevented by the rotary valves or piston itself. Positive displacement pumps are usually self-priming.

Harton anlagentechnik gmbh
Harton anlagentechnik gmbh

Electric diaphragm pumps are pumps that operate according to the displacement. The axial deformation of the diaphragm, the medium of the pumping chamber is moved into the discharge line. By resetting the diaphragm to its initial state, the medium is sucked into the pumping chamber. Valves prevent the return flow of the liquid. The diaphragm is the sealing element to the atmosphere. Diaphragm pumps are self-priming and suitable for dry running. Since the service life of the membranes may be limited depending on use, this may need to be replaced.

Air operated diaphragm pumps

Air-operated diaphragm pumps are pumps that operate according to the displacement. The compressed air flows alternately in the two membranes. The axial deformation of the diaphragm, the medium of the pumping chamber is moved into the discharge line.

After the escape of compressed air behind the diaphragm, the diaphragm is returned to its original state and the medium is sucked into the pumping chamber. Valves prevent the return flow of the liquid. The diaphragm is the sealing element to the atmosphere. Diaphragm pumps are self-priming and suitable for dry running.

Harton anlagentechnik gmbh
Harton anlagentechnik gmbh

Impeller pumps

Impeller Pumps are rotary positive displacement pumps with pulsation-free and continuous flow. The flexible impeller rotates eccentrically arranged feed chamber. The vanes of the impeller to turn at the costs associated with the eccentric arrangement bottleneck and the pumped liquid is pressed out. If the blades open again in the further course, a new medium is drawn … The direction is reversible.

The pump also media containing particles such. Ex. Beer remains, seeds or stems. The pumps are self-priming and geeigne for short-term dry running

Harton anlagentechnik gmbh
Harton anlagentechnik gmbh

Micro annular gear pumps

Micro annular gear pumps are positive displacement rotary miniaturized. They are based on the so-called micro annular gear principle with an externally toothed internal rotor and an internally toothed outer rotor. The inner rotor has one less tooth than the outer rotor. To use the gear ratios get 6/7 and 10/11. The manufacturing tolerances of the rotors are a few microns in the area.

Harton anlagentechnik gmbh
Micro Gear pump Harton

The product range includes five series of micro annular gear pumps for metering and promoting low volume liquid low to high viscosity media. With different equipment dosing volumes are from 0.25 .mu.l, flow rates of 1 ul / h to 1.1 l / min and pressures from 0 to max. 150 bar feasible. The range of media viscosity ranging from 0.3 to 1,000,000 mPas.

They are suitable for lubricating and non lubricating liquids. Operation in explosion-proof area is also possible. The pumps are characterized by low pulsation, low-shear promotion, low void volume, long service life, low weight and a compact design, self-priming behavior and wear and corrosion resistant materials.

Also Read : Alcor temperature probes and instruments

Pemo Pumps

Built Rugged for Exceptionally Life in Tought Applications.

Harton anlagentechnik gmbh
Pemo Pump Harton

Mining, Aggregate, Quarry & Mineral Extraction: PEMO Pumps are commonly used to feed hydrocyclones and transfer slurries in these applications.
Filter press Feed: Thanks to the unique Double Stage design, PEMO pumps stand alone in the filter press feed industry.
Stone Processing: PEMO is a world leader in the granite and marble industry.
Ceramics: PEMO is a world leader for pumps that transfer ceramic slip.
Chemical Process: PEMO pumps are used in the chemical industry for applications with both acids and abrasive slurries.
Steel Mills: Robust PEMO pumps are widely used to transfer hot water up to 100°C (180°F) containing oil and / or metal particles.
Power Plants: PEMO pumps are used for coal slurries, flyash, and SO2 scrubbers.

Horizontal Pumps

  • Designed for heavy duty slurry and / or acids.
  •  These are suction pumps with single or double mechanical seal.
  •  Capacities from 1 to 1500 m3 / h (5-6613 gpm).
  •  Usually maximum discharge pressure should not exceed 3 bar or 43 psi.
  •  The heart of PEMO product line, the AO / AB pump series, are truly unique. Due to the side
    Inlet the maximum pressure on the mechanical seal will see is the inlet pressure,
    greatly increasing life of the seal.
  •  Handling of aggressive media, acids, the shaft and the mechanical seal is
    made of special alloys.
  •  Maximum particles size is 2 mm, and is dependent on the specific application.
  •  Capacities from 1 to 900 m3 / h (5 to 3.968 gpm).
  •  Maximum discharge head is 90 m (295 ft) in the Hardalloy PEMO design.
  •  The AO / AB / DC-series is the perfect solution for filter press feed or slurry transfer.
  •  Handling of aggressive media, acids, the shaft and the mechanical seal housing
    can be made of special alloys.
  •  Maximum particle size is 1 mm and is dependent on the specific application.
  •  Capacities from 5 to 600 m3 / h (22 to 2.645 gpm).
  •  Maximum discharge head is 180 meters (590 ft) in Hard Alloy PEMO design.
Harton anlagentechnik gmbh
Horizontal Pump Harton

Horizontal double stage pumps

  • Designed for slurries and / or acids.
  •  The AO / AB / DC-series is the perfect solution for filter press feed or slurry transfer.
  •  Handling of aggressive media, acids, the shaft and the mechanical seal housing
    can be made of special alloys.
  •  Maximum particle size is 1 mm, and is dependent on the specific application.
  •  Capacities from 5 to 600 m3 / h (22 to 2.645 gpm).
  •  Maximum discharge head is 180 meters (590 ft) in Hardalloy PEMO design.
Harton anlagentechnik gmbh
Horizontal Double Stage Pump Harton

Vertical Pumps

  • Designed to support heavy slurris and / or aggressive fluids, acids.
    Vertical pumps are manufactured in three different series:
  •  VEC – The VEC pump series corresponds to specific customer requirements.
  •  MEC – The MEC pump series has a direct transfer via a elastic joint. The engine is equipped with a protection and a Eyebolt for transport / assembly provided.
  •  OFF – The OFF-series pumps are suitable for dry running, because without mechanical seal.
Harton anlagentechnik gmbh
Vertical Pumps Harton

Submersible Pumps

  • Abrasive liquids with suspended solids
  • Depth or inaccessible bays
  •  Operating under the water surface
  •  Double mechanical seal with permanent lubrication
  •  No need for maintenance
Harton anlagentechnik gmbh
Submersible Pumps Harton

Also Read : TAKK Industries – Static Control and Static Elimination

Drum & Container Pumps

Harton anlagentechnik gmbh
Drum & Container Pumps Harton

Refference : https://www.harton.de/ 

Similar Posts