KAWAKI MEASURING INSTRUMENT Co., LTD has manufactured parts of shield machine of major heavy industry manufacturers, hydraulic pressure-related parts of major machine manufacturers, and parts for protecting voltage inverters of major heavy electric manufacturers in addition to flow rate measurement gauge (flow meter, flow switch, flow sight etc.) since the initiation in April 1948. We are developing and manufacturing various types of flow meters to meet a very wide range of market requests.

Measurement of flow rate is necessary for comprehending and controlling quantities that are directly linked to manufacturing activity such as production volume of product, amount of raw materials usage, and consumption of energy (steam, fuel, etc.).

It is also necessary for maintaining and managing the water and sewerage disposing facilities, transportation of liquid, business transaction, and monitoring the discharge of pollutant, in addition to manufacturing activity.

On the other hand, there are various targets of flow rate measurement; gas, liquid, steam, powder and granular material. Furthermore, a lot of materials such as high-temperature and high-pressure steam, ultra low-temperature liquefied gas, slurry liquid (liquid containing much solid), pulp liquid, concentrated sulfuric acid, caustic soda, deep etching liquid such as plating liquid, high viscosity fluid such as kneading candy and grease cannot be measured easily.

The flow in conduits such as sewage and factory disposal that have open water surface, the air flow, and the flow of powder and granular material in open spaces are also targets of flow rate measurement, in addition to liquid and gas that flows in pipe lines.

Kawaki Product List

Flow Variable Area Flow Meter and Flow Switch

Kawaki Flow Switch and Flow MeterLogo.jpg
Kawaki Flow Switch and Flow MeterLogo.jpg

SF type flow switch / flow meter

  • Suitable for high-temperature and high-pressure liquid of unclear liquid (oil etc.)
  • The contact of flow switch is the internal variable type, however, if you change the contact frequently, the external variable type is also manufactured.
  • For use outdoors and at places with bad environment, totally waterproof type (IEC, IP67) is also manufactured.

Specification

Type SF-M type instantaneous flow rate indicator
SF-MA type instantaneous flow rate indicator + with lower limit (upper limit) contact
SF-MAA type instantaneous flow rate indicator + with lower limit (upper limit) contact
Bore 3/8B to 12B Flange type
RC3/8 to RC1.1/2 Screw type
Withstanding pressure Standard product 1.0MPa
Special order item 3.0MPa and above
Temperature Standard product 80°C or less
Special order item 300°C or less
Accuracy Each indication scale ±3%
Capacity of contact For the micro switch used for the contact, three types shown below are separately used depending on bore and flow rate.
*15A: 125,250VAC、0.5A: 125VDC、0.25A: 250VDC
*5A: 125,250VAC、0.5A: 125VDC、0.25A: 250VDC
*10A: 125,250VAC
Material of main unit FC250,CAC406,SS400,SUS304,SUS316,SUS316L etc.
Material of main section C3604B,SUS304,SUS316,SUS316L etc.
Remark *For places with frequent vibration, please use earthquake resistant type.

FY type flow switch / flow meter

  • Suitable for comparatively small flow rate (equivalent to water 0 to 15L/min) of high-temperature and high-pressure fluid of unclear liquid (oil, etc.)

Specification

Type FY-M type instantaneous flow rate indicator
FY-M type instantaneous flow rate indicator
Bore 3/8B to 12B Flange type
RC3/8 to RC1.1/2 Screw type
Withstanding pressure Standard product 1.0MPa
Temperature Standard product 80°C or less
Accuracy Each indication scale ±3%
Capacity of contact *5A: 125,250VAC,0.5A: 125VDC,0.25A: 250VDC
Material of main unit FC250,CAC406,SUS304
Material of main section C3604B,SUS304
Remark *For places with frequent vibration, please use earthquake resistant SF type.
*If the use pressure is 1.0MPa or more, use SF type for high pressure.
*For use outdoors and at places with bad environment, totally waterproof type (IEC, IP67) is also manufactured

SA type flow switch / flow meter

  • This flow meter / flow switch is the down-sized SF type and the features are same as those of SF type and SA type.
  • The external variable type is also manufactured.

Specification

Self-holding proximity switch SA-M type instantaneous flow rate indicator
SA-MA type instantaneous flow rate indicator + with lower limit (upper limit) contact
SA-MAA type instantaneous flow rate indicator + with lower limit (upper limit) contact
Bore 3/8B to 1B Flange type
RC3/8 to RC1 Screw type
Withstanding pressure Standard product 1.0MPa
Temperature Standard product 80°C or less
Special order item 300°C or less
Accuracy Each indication scale ±3%
Capacity of contact *50W: 0.5A,125VAC
Self-holding proximity switch
Material of main unit FC250,CAC406,SS400,SUS304,SUS316,SUS316L etc.
Material of main section C3604B,SUS304,SUS316,SUS316L etc.
Remark *For places with frequent vibration, please use earthquake resistant type.

KY type flow switch / flow meter

  • Suitable for unclear liquid because the indication part is separated using a mechanical seal
  • Flow direction is not restricted
  • Contact position is variable

Specification

Type KY-M type instantaneous flow rate indicator
KY-MA type instantaneous flow rate indicator + with lower limit (upper limit) contact
Bore 3/8B to 5B Flange type
RC3/8 to RC1.1/2 Screw type
Withstanding pressure Standard product 1.0MPa
Temperature Standard product 80°C or less
Accuracy Each indication scale ±5%
Capacity of contact *15A: 125,250 or 480VAC,0.5A: 125VDC,0.25A: 250VDC
Application Suitable for indication and warning of flow rate of lubrication oil quantity
Suitable for indication and warning of flow rate of fluid that contains iron powder
Material of main unit FC250,CAC406,SUS304
Material of main unit C3604B,SUS304
Remark *For places with frequent vibration, please use earthquake resistant SF type.
*If the use pressure is 1.0MPa or more, use SF type for high pressure.
*The range of minimum scale is 0 to 30L/min (water) and 0 to 20L/min (oil).

Orifice Flow Meter

Orifice flow meter

A simple structure that attaches a flow rate indicator to the corner tap orifice  realizes superior cost performance and low-cost flow rate measurement even for large bore. Various types of flow rate indicators are lined up to meet wide-ranging needs.

  • Can select either digital indication or analog indication.
  • For relay output, up to two contacts are available.
  • Various output signals such as analog signal and HART communication function are available.
  • If power supply cannot be ensured, the analog indicator type or the digital indicator is supported by a built-in battery type.

Spescification.

Type ODF
Fluid to be measured Liquid, gas (however, for corrosive fluid, please contact us)
Bore Wafer connection, flange connection
15A to 100A : JIS 5K/10K/16K/20K/30K FF/RF
1/2” to 4” : ANSI#150Lb #300Lb
Maximum use pressure Max. 2.0MPa (standard product) (for high pressure, please contact us)
Temperature of fluid -10~70°C(standard product)
Accuracy F.S. ±5%
Installation location can be installed outdoors <IP65> (however, please avoid direct sunlight)
Material of main unit SS400,SUS304,SU316,SUS316L etc.
Material of plate SUS304,SUS316,SUS316L etc.
Remark *If you are worried about pressure loss, please contact us.
*Both horizontal piping and vertical piping can be used.
*Drain for drainage can be installed.
Example of use *Cooling water line by purified water, industrial water, coolant liquid, etc.
*Gas line of air, nitrogen, etc.
*General process line

Orifice flange / orifice plate

Also possible to manufacture only either the orifice flange or the orifice plate

Specification

Orifice type Flange tap orifice, corner tap orifice (ring orifice), D.1/2D tap orifice
Fluid to be measured liquid, gas
Bore Wafer connection, flange connection
15A to 100A JIS 5K/10K/16K/20K/30K FF/RF
1/2” to 4” ANSI#150Lb #300Lb
Port for removing the differential pressure flange connection (JIS, ANSI, JPI, etc.), screw connection (Rc, NPT, PF(G)) 15A and above
Differential pressure designed and manufactured with a specified differential pressure
Material of main unit SS400,SUS304,SU316,SUS316L etc.
Material of plate SUS304,SUS316,SUS316L etc.
Material of sealing various O-rings, various type of packing (decide after meeting)
Remark *If you are worried about pressure loss, please contact us.
*Both horizontal piping and vertical piping can be used.
*Drain for drainage can be installed.
*Drain hole and ventilation hole can be installed.
Example of use *Cooling water line by purified water, industrial water, coolant liquid, etc.
*Gas line of air, nitrogen, etc.
*General large bore process line

Flow Sight / Flow Indicator

Kawaki Flow Sight
Kawaki Flow Sight

FS type flow sight (transparent type sight glass)

Data sheet

Type FS-I: without flapper
FS-II: with flapper
FS-B: ball contained
FS-I-N: with nozzle
FS-IV: for both purposes of forward and reverse
FS-IV: for both purposes of forward and reverse
FS-W: with wiper
Bore 3/8B to 6B flange type (special order item to 12B)
3/8B to 2B screw type
Withstanding pressure 1.0MPa
Temperature 80°C or less (Standard product)
Material Main unit: FC250,FC450,CAC406,SS400,SUS304,SUS316
Main section: C2801P,SUS304,SUS316
Remark For FS-II and FS-IV types, outline flow rate scales can be carved.

FS-M / FS-O type flow sight (magnet servility type)

With FS type, the index cannot be seen clearly due to oil or taint on window glass. However, with this flow sight type, the flow rate can be seen “clearly” because the index is attached on the outside of wetted surface.

Data sheet

Type FS-M : Magnet servility type flow sight
FS-O : Magnet servility type flow sight for small flow rate
Bore *FS-M
3/8B to 6B Flange type (special order item to 12B)
3/8B to 2B Screw type
*FS-O
3/8B to 1B Flange type (special order item to 12B)
3/8B to 1.1/2B Screw type
Withstanding pressure 1.0MPa
Temperature 80°C or less (Standard product)
Material Main unit: FC250、FC450、CAC406、SS400、SUS304、SUS316
Main section: C2801P、SUS304、SUS316
Remark The model of this flow sight that complies with the Fire Service Act is FS-K type.

FS-C / FS-N flow sight type with needle valve

Type FS-C : As a cap is attached to the needle valve, other people cannot touch it easily once the oil quantity is set.
FS-N : the needle valve is a 2.0MPa type for earthquake resistant and high-accuracy fine adjustment is possible
Bore FS-C : 1/4B to 1.1/2B Screw type
FS-N : 1/4B to 1B Screw type
Withstanding pressure 1.0MPa
Temperature 80°C or less (Standard product)
Material *FS-C
Flow sight : Main unit FCD450, Main section C2801P
Needle valve : Main unit CAC406, Main section C3604B
*FS-N
Flow sight : Main unit FCD450, Main section C2801P
Needle valve : Main unit C3771B, Main section C3604B
Remark FS-K type comes with a protection cover made of steel complying with the Fire Service Act, and is without a window glass in order to prevent the damage of window glass. For small flow rate or when black oil is measured, please use FS-O type.

FI type sight feed indicator

The flow direction is side to bottom and a needle valve is attached to the inlet side for adjusting the amount of lubrication.

Type FI-1 to FI-12
Bore FI-1 type : RC1/4×RC1/2 : Maximum flow rate 3L/min
FI-2 type : RC3/8×RC1/2 : Maximum flow rate 3L/min
FI-3 type : RC1/2×RC1/2 : Maximum flow rate 3L/min
FI-4 type : RC1/4×RC3/4 : Maximum flow rate 5L/min
FI-5 type : RC3/8×RC3/4 : Maximum flow rate 5L/min
FI-6 type : RC1/2×RC3/4 : Maximum flow rate 5L/min
FI-7 type : RC3/4×RC3/4 : Maximum flow rate 5L/min
FI-8 type : RC1/4×RC1 : Maximum flow rate 5L/min
FI-9 type : RC3/8×RC1 : Maximum flow rate 5L/min
FI-10 type : RC1/2×RC1 : Maximum flow rate 5L/min
FI-11 type : RC3/4×RC1 : Maximum flow rate 5L/min
FI-12 type : RC1×RC1 : Maximum flow rate 10L/min
Withstanding pressure 1.0MPa
Temperature 80°C or less (Standard product)
Material Main unit : AC-8BT6, Main section : C3604B, Needle valve : SUS304
Remark Product with a protection cover made of steel complying with the Fire Service Act is also manufactured for preventing the damage of window glass.

MFI type multi flow sight

Type MFI-1 type (1-strand) to MFI-10 type (10-strand)
Bore Inlet: 3/8B to 3/4B screw type
Outlet: 3/8B screw type
Flow rate 0 to 6L/min at 220mm2/s. 0.2MPa
Withstanding pressure 0.5MPa
Temperature 80°C or less (Standard product)
Material Main unit : SS400,C3604B,SUS304
Main section : S25C,C3604B,SUS304
Float : C3604B,SUS304
Remark 3 to 4-point scale can be attached as an option.

Kawaki Variable Area Flow Meter

  • SR type flow meter
  • KNR type flow meter
  • NF type flow switch
  • INF type flow meter / flow switch

Other Article:

author

Rudy Wiratama

rudywinoto.com/wmablog.com/flowmasonic.com