Schreiner LPC 528

Description

Schreiner LPC 528 makes a unique auto test setup possible. The communication via RS232, USB, Ethernet, and ProfiNET includes parameters, results, counters, and statistics at baud rates up to 115,200 for RS232. The LPC 528 is characterized by excellent measuring accuracy, simple intuitive operation, and durability.

  • Unique auto test setup
  • Multilingual software
  • ProfiNET, RS232, Ethernet
  • Color graphic display
  • Intuitive user interface
  • Compact modular design
  • Self-test diagnostics verification

Schreiner LPC 528 Description

  • High speed 32 bit processor
  • 32 freely programmable measuring programs
  • RS232, TCP/IP (Telnet), EtherNet/IP™ and PROFINET a communication interfaces
  • External calibration port for automatic calibration routine using calibrated leak standard
  • Environmental drift correction
  • Data collection & storage of up to 5,000 test results
  • Real-time data transmission (0.05 seconds) via RS232
  • High resolution 24 bit A/D converter
  • Versatile test capabilities including pressure/vacuum decay, differential pressure decay, and occlusion
  • Multi-level password protection
  • Quick test function to reduce cycle times
  • Self-test functions: internal pneumatic leak check, calibration test, transducer zero and span calibration, test regulator adjustment

Schreiner LPC 528 Technical Specifications

Housing (WxHxD)270 x 170 x 260 mm
(10.6 x 6.7 x 10.3 in)
Weight6-7 kg (13.2-15.7 lbs)
Rated Voltage Range120 V AC 1A /
230 V AC 0.5 A
ProtectionIP30
Air SupplyAir, nitrogen
Dried ISO 8573-1 Class 2 Compressed air dew point
-40 °C (-40 °F)
Filtered with min. 1 µm Up to 1 mg/m³ of oil
Operating Temperature Range5-45° C (39.2-113 °F)
Max. Humidity80 % rH not condensing
Power Supply (24 V optional)M12 Connection 24 V max. 2 A

Display

  • Vivid, color LCD display with icon menu screen for easy navigation
  • Bar graph test results, digital test results, test parameters, test counters, and test statistics
  • Displays test specific units of measurement
  • Test result lights for “In Test”, “Accept”, and “Reject”
  • Language neutral keypad

Interfaces

  • Communication via RS232, USB, TCP/IP (Telnet), EtherNet/IP™, and PROFINET
  • Tooling control for simple applications
  • Digital I/O – 6 inputs/3 outputs independently set per part program

Accessories

  • Calibrated test leak and leak simulator
  • Vacuum pump
  • Filter kit
  • CTS-Schreiner Connect® Seals

Options

  • Differential pressure or pressure decay manifold
  • Electronic or manual pressure regulator
  • Externally mounted calibrated leak standard
  • Selectable pressure packages
  • Selectable transducer ranges
  • PROFINET communication interface
  • EtherNet/IP communication

Test Capabilities

  • Pressure/vacuum decay – ?P
  • Pressure/vacuum decay – ?P/?T
  • Pressure/vacuum decay – leak standard
  • Differential Pressure Decay (?P)
  • Differential Pressure Decay Leak Rate (DP Test Type Only)
  • Differential Pressure Decay Leak Standard
  • Occlusion (Back pressure)

Measuring ranges

Pressure DecayVacuum DecayDifferential Pressure DecayDifferential Vacuum Decay
Test Pressure Range0 to 13.8 bar (gauge)-1 to 0 bar (gauge)0 to 13.8 bar (gauge)-1 to 0 bar (gauge)
Test Pressure Control1.5 % FS1.5 % FS1.5 % FS1.5 % FS
Accuracy
Measuring Range-1 to 13.8 bar (gauge)-1 to 0.4 bar0 to 0.345 bar (differential)0 to 0.345 bar (differential)
Measuring Accuracy± 0.4 % FS± 0.4 % FS± 0.006 % FS± 0.006 % FS
Resolution< 6.8 bar: 0.1 Pa0.1 Pa0.007 Pa0.007 Pa
< 13.8 bar: 1 Pa