Description
The ES transmitter is used in combination with the BGN, BGF, and TSK series of flowmeters, as well as in BA level meters. As a result, the areas of both volume and mass flow rate as well as level measurement according to the displacer principles are covered. For the installation in potentially explosive gas atmospheres, the ES transmitter is intended for use in an enclosure providing a degree of protection of at least IP 20.
Applications
The transmitter can be used with the following Heinrichs instruments:
- Variable Area Flow Meter BGN and BGF
- Flap Flow Meter TSK
- Liquid Level Meter BA
- Density Meter DWF
Reliability
Robust, durable, potted electronic
The geomagnetic field is compensated by a differential measurement
Approvals and certificates
Explosion protection:
EC-Type Examination Certificate DMT 00 ATEX E 075
Ignition category II 2G EEx ia IIC T6
CE-mark: Explosion Protection Directive 94/9/EC
Electromagnetic Compatibility. EMC-Directive 89/336/EEC
Communication
HART-protocol
HART-protocol and 2 NAMUR-switches
HART-protocol and 1 NAMUR-switch / pulse output
HART-protocol and counter module
Profibus-PA
Foundation Fieldbus
Technical Data:
Power supply: | 14 – 30 VDC |
Outputs: | passive, galvanically isolated |
Analog: | 4-20 mA |
Binary 1 and 2: | Ui=30 V, Ii=20mA, Pi=100 mW |
Input binary: | Counter reset (only for ES with counter module) |
Ambient temperature: | -40°C up to +70°C |
To be installed in a case of ingress protection at least IP 20 (EN60529) | |
Accuracy ± 0,2% |
Download Catalog: Model ES Electronic transmitter-Heinrichs
Ref: Heinrichs.com
Other Article:
- Hengesbach Pressure Transmitter DME 11 Series
- Differential Pressure Transmitter D32 Series Delta Mobrey
- LEEG Pressure Transmitter, Sensor and Switch
- D22 Pressure Transmitter Delta Mobrey
- 8000 SAN Pressure Transmitter Delta Mobrey