Weidmuller ACT20X HART® Transparent Driver

Description

The Weidmuller ACT20X-SAI-HAO/2SAI-2HAO current output isolators are suitable for controlling field devices in Ex areas, up to Zone 0. The input/output-side HART protocol transparent signal connection is implemented using 4 to 20 mA current loops.

Integrated alarm contacts issue an alert in the event of a malfunction; this makes troubleshooting easier and increases system availability. The rail-mounted current output isolators are optionally available in one- or two-channel versions. With an 11 mm width per channel, the devices need little space in the electrical cabinet.

Feature

  • HART-compatible for 0.5…2.5 kHz
  • Configuration and diagnosis via FDT/DTM Software “WI-Manager”.
  • The device can be mounted in the safe area and in zone 2 / division 2 and receive signals from zone 0, 1, 2, 20, 21, and 22, as well as Class I/II/ III, division 1, group A-G.
  • The mA current signal inputs are completely electrically isolated.
  • The device detects automatically whether an active or passive current signal is connected.
  • Extended self-diagnostic: Monitoring of error events (e.g. cable breakage) via status relay.
  • Front LEDs indicate operation status and malfunction.
  • 3-way galvanic isolation between input, output, and power supply.

Specifications (ACT20X and ACT20X-SAI-HAO-S)

Dimensions and weights

  • Width: 22.5 mm
  • Width (inches): 0.886 inch
  • Height: 119.2 mm
  • Height (inches): 4.693 inch
  • Depth: 113.6 mm
  • Depth (inches): 4.472 inch
  • Net weight: 189 g

Temperatures

  • Humidity : 0…95 % (no condensation)
  • Operating temperature, max. : 60 °C
  • Operating temperature, min. : -20 °C
  • Storage temperature, max. : 85 °C
  • Storage temperature, min. : -20 °C
  • Operating temperature: -20 °C…60 °C
  • Storage temperature: -20 °C…85 °C

Probability of failure  MTBF: 135 Years

Environmental Product Compliance  REACH SVHC: Lead 7439-92-1

Rated data UL  UL certificate: E337701.pdf

Input EX

  • Input current: 4…20mA
  • Input frequency : 0,5…2,5 kHz @ 3,5…23 mA bi-directional HART® signal
  • Output signal in case of wire break: < 1 mA
  • Voltage drop: < 2 V
  • Voltage drop not powered: < 6 V
  • Voltage drop powered: < 2 V

Input

  • Input current: 4…20mA
  • Input frequency : 0,5…2,5 kHz @ 3,5…23 mA bi-directional HART® signal
  • Voltage drop: < 2 V

Output

  • Type: intrinsically safe circuit
  • Influence of load resistance: ≤ 0.01% of span / 100 Ω
  • 2-wire supply : > 14.5 V @ 20 mA
  • Output signal limit: < 28 mA
  • Residual ripple (current loop): < 7.5 mVeff
  • Output current: 4…20 mA (max. 23 mA)
  • Cut-off frequency (-3 dB) : 0.5…2.5 kHz @ 3.5…23 mA bi-directional HART® signal
  • Load impedance current: ≤ 725 Ω

Alarm output

  • Alarm function: Signal limit exceeded, Line interruption at the input, No supply voltage, Device error
  • Type: Relay, 1 NO (voltage-free)
  • Nominal switching voltage :
    • ≤ 125 V AC / 110 V DC (safe area)
    • ≤ 32 V AC / 32 V DC (zone 2)
  • Continuous current : ≤ 0,5 A AC / 1 A DC (zone 2)
  • Power rating :
    • ≤ 62.5 VA / 32 W (safe area)
    • ≤ 16 VA / 32 W (Zone 2)
  • Hysteresis :
    • 0.1 mA (switching threshold)
    • Switching thresholds 0…29.9 mA (programmable)

General specifications

  • Configuration: With FDT/DTM software
  • Voltage supply: 19.2…31.2 V DC
  • Type of connection: Screw connection
  • Power consumption: ≤ 1.0 W
  • Accuracy: < 0.1% span
  • Temperature coefficient: < 0.01% of span/°C (TU)
  • Step response time: ≤ 5 ms
  • Protection degree: IP20
  • Humidity : 0…95 % (no condensation)

Insulation coordination

  • EMC standards: DIN EN 61326, NE 21
  • Insulation voltage: 2.6 kV (input/output)
  • Rated voltage: 300 V

Data for Ex applications (ATEX)

  • Voltage U0: 28 V DC
  • Current I0 : 93 mA
  • Power P0 : < 650 mW
  • Marking:  II (1) G [Ex ia Ga] IIC/IIB/ IIA, II (1) D [Ex ia Da] IIIC, I (M1) [Ex ia Ma] I
  • Installation location: The device was installed in a safe area, zone 2

Safety-related basic specifications

  • Demand mode: High
  • Description of the “safe state”: analog Output ≤ 3.6 mA or output ≥ 21 mA
  • Device type: A
  • Hardware fault tolerance (HFT) : 0
  • Mean Time To Repair (MTTR): 24 h
  • Safe Failure Fraction (SFF): 85 %
  • Tproof: 5 Years
  • The total failure rate for dangerous detected failures (λDD): 127 FIT
  • The total failure rate for dangerous undetected failures (λDU): 48 FIT
  • The total failure rate for safely detected failures (λSD) : 0 FIT
  • The total failure rate for safe undetected failures (λSU): 164 FIT
  • Safety category: SIL 2
  • Probability of outage PFH : 4.8 x 10-8 h-1

Safety-related specifications Low demand mode

  • Average Probability of Failure on Demand (PFDavg) :
    2.29 x 10-4 (Tproof = 1 year), 4.37 x 10-4 (Tproof = 2 years), 1.06 x 10-4 (Tproof = 5 year)

Connection data

  • Type of connection: Screw connection
  • Tightening torque, min. : 0.4 Nm
  • Tightening torque, max. : 0.6 Nm
  • Clamping range, rated connection: 2.5 mm²
  • Clamping range, min. : 0.25 mm²
  • Clamping range, max. : 2.5 mm²
  • Wire connection cross-section AWG, min. : AWG 26
  • Wire connection cross-section AWG, max. : AWG 12

Classifications

  • ETIM 6.0: EC002475
  • ETIM 7.0: EC002475
  • eClass 9.0: 27-21-01-23
  • eClass 9.1: 27-21-01-23
  • eClass 10.0: 27-21-01-23
  • USPS: 30-21-18-01

Product information

  • Weidmüller provides an extended guarantee period of 36 months for this device.

Approvals

  • UL, Ex, DNV, DNV-GL, EAC, FM, IECEx
  • ROHS: Conform

Download Datasheet: Weidmuller HART® Transparent Driver

Reference : weidmueller.com