Hengstler 486-487 Preset Counter

Hengstler 486-487 Preset Counter is an electronic adding preset counter. It is available with a 3 or 5-digit display and the preset remains visible at al times. Depending on the version, Type 486-487 offers manual, electric or even optional automatic reset. It is a plug-and-play device and can easily be combined with other counters in the modular 400 series.

Totalizing counters tend to be used to register the number of events and display the result as a digital numerical value. The key characteristics of this versatile range of products, as you would expect from any HENGSTLER product, are state-of-the-art technology, appealing design, quality and reliability. Examples of typical applications: Production counting, recording flow volume.

Hengstler 486-487 Preset Counter Features

  • Permanently visible preset
  • Reset manual, electric or automatic
  • Display 3 or 5-digit
  • Plug-and-play in Modular System 400

Another Article:

Specification

Product Family 486/487
Function Preset counter
Technology Electromechanical
Digits 3-digit
5-digit
Display 3-digit
5-digit
Preset 1 preset
Digit Height [mm] 4 mm (0.2 in)
Voltage 12 – 220 VDC
24 – 230 VAC
Reset manual reset
electrical reset
key reset
Signal Times from when preset has been reached until reset
Duty Cycle at 25 °C DC: counter 100%, reset magnet: 20%, max. 2 min.
AC: counter 100 %, reset magnet: 10 %, max. 1 min
Duty Cycle at 50 °C counter 50 % max. run time 10 min
Pulse Duty Factor Reset Impulse DC: 1:5
AC: 1:10
Power Consumption DC: counter 2.5 W, reset magnet 12 W
AC: counter 2.75 VA, reset magnet 16 VA
Pulse Length min. DC: counter 20 ms, reset magnet 200 ms
AC: counter 50 ms, reset magnet 200 ms
Residual Ripple [%] DC: 48 %
Supply Voltage 12, 24, 48, 60, 110, 220 VDC
24, 42, 48, 100, 115, 200, 230 VAC
Contact Type floating changeover contact
Switching Voltage max. 220 V AC
Switching Current max. 20 VA / 1 A
non-inductive
Count Frequency [Hz] DC: counter 25 Hz, reset magnet 1 per s
AC: counter 10 Hz, reset magnet 1 per 2 s
Count Input adding
Pulse Duty Factor Count Impulse DC: counter 1:1
reset magnet: 1:5
AC: counter 1:1
reset magnet: 1:10
Reset Frequency DC: max. 1 per s
AC: max. 1 per 2 s
Electrical Connection AMP connector plug 0.8 x 2.8 mm (0.3 x 1.1 in) (via connection box)
Maintenance-Free operation counter 2 x 10 pulses
reset magnet 1.5 x 10 pulses

Download Data Sheet: Preset Counter Type 486/487

Ref: hengstler.de

Share