Description of Seametrics FT Series FT430/440/450 Rate/Total Indicator
Seametrics FT Series FT430/440/450 Rate/Total Indicator are microcontroller-based indicator/transmitters that interface with pulse output flow sensors to compute and display flow rate, and flow total, and also generate output signals representing flow. The FT430 and FT450 have one scaled pulse output and one pulse pass-through. The FT440 has two scaled pulse outputs.

Seametrics FT Series is battery-powered while the FT430 may be powered by an external DC power source or an optional internal AC power supply*. The FT440 is a “two-wire” or “loop-powered” device, meaning that it is powered by the 4-20 mA loop circuit itself. An optional internal AC power supply* is available for the FT440 with dual 24 and 12VDC outputs to power both the loop and sensors requiring more power than the loop can supply.
Pulse and 4-20mA analog outputs can be used to signal external devices, e.g. certain metering pumps and water treatment controls. Alternatively, one or more pulse outputs can be configured as alarm outputs.
These flow computers can be password-protected to prevent resetting the total or changing configuration settings. The FT430/440/450 indicators are available in wall and meter mount configurations. The FT430 and FT440 models can also be panel mounted. Order the FT440 only if a 4-20mA output signal is a requirement or the FT450 if internal battery power is needed. Otherwise, the FT430 can be ordered.
Features of Seametrics FT Series FT430/440/450 Rate/Total Indicator
- Simple Setup
- DC Powered (FT430)
- Loop Powered (FT440)
- Battery Powered (FT450)
- Remote or Flow Sensor Mounted Indicator
- Rugged Plastic Housing
- Non-volatile Memory
- Data Logging (Optional)
- Sensus Smart Output (Optional)
Application of Seametrics FT Series FT430/440/450 Rate/Total Indicator
- Water Treatment
- Water Utility
- Industrial Processes
- Reuse/Reclaim Water
- Dewatering
- Irrigation
- Well Usage Monitoring
Specification of Seametrics FT Series FT430/440/450 Rate/Total Indicator
FT430 | FT440 | FT450 | ||
Power | 7-30Vdc, 4mA | 9-30Vdc, 4mA (4-20 mA when loop-powered) | Lithium “C”, 3.6Vdc, replaceable. Life is ~5 years depending on usage. | |
Display | Rate | 5-digit auto-range | 5-digit auto-range | 5-digit auto-range |
Total | 8-digit | 8-digit | 8-digit | |
Units | Rate Unit | Gallons/Second/Minute/Hour/Day, Liter/Second/Minute/Hour/Day, Cubic Feet/Second/Minute/Hour/Day, Cubic Meters/Second/Minute/Hour/Day, Mega Liters/Day, Million Gallons/Day, Fluid Oz/Second/Minute/Hour/Day, Barrels/ Second/Minute/Hour/Day | ||
Total Unit | Gallon, Gallon x 1000, Liters, Mega Liter, Cubic Meter, Acre Feet, Cubic Feet, Cubic Feet x 1000, Million Gallon, Acre Inch, Fluid Ounce, Barrels | |||
Output | Pulse Output 1 | Scaled pulse output, high alarm output, or low alarm output. Optoisolated on FT430 and FT440. | ||
Pulse Output 2 | Pulse pass-through | Scaled pulse output, high alarm output, or low alarm output. | Pulse pass-through | |
Loop Power Output | N/A | 4-20mA Loop | N/A | |
Sensus Smart Output | Optional | Optional | Optional | |
Set P Range | 0.1 – 99999.9 units/pulse | 0.1 – 99999.9 units/pulse | 0.1 – 99999.9 units/pulse | |
Input | 5V pulse or contact closure | Micropower GMR Sensor (square wave) | 5V pulse or contact closure | |
Input Range | – 2000Hz | – 2000Hz | – 550Hz | |
K-Factor Range | .001 – 999999.999 | .001 – 999999.999 | .001 – 999999.999 | |
Flow Alarm Output Range | 0.1 – 99999.9 | 0.1 – 99999.9 | 0.1 – 99999.9 | |
Operating Temperature | -5? to 55? C (23? to 131? F) | -5? to 55? C (23? to 131? F) | -5? to 55? C (23? to 131? F) | |
Non-Operating Temperature | -40? to 75? C (-40? to 158? F) | -40? to 75? C (-40? to 158? F) | -40? to 75? C (-40? to 158? F) | |
Environmental | NEMA 4X, IP67 | NEMA 4X, IP67 | NEMA 4X, IP67 | |
Regulatory | ? MARK | ? MARK | ? MARK |
Pulse Output Function Table
PULSE OUTPUT 1 (SCALED) | FT430 | FT440 | FT450 | |
TYPE | Current sinking | Current sinking | Current sinking | |
MAX. VOLTAGE | 36 Vdc | 36 Vdc | 36 Vdc | |
MAX. CURRENT | 100 mA | 100 mA | 100 mA | |
MAX. FREQUENCY | 6.5 Hz | 6.5 Hz | 6.5 Hz | |
PULSE WIDTH | 100 ms | 100 ms | 100 ms | |
ISOLATION | 300 V | 300 V | NOTE 1 | |
CONFIGURABLE AS ALARM | YES (High or Low) | YES (High or Low) | YES (High or Low) | |
PULSE OUTPUT 2 (SCALED) | FT430 | FT440 (Note 2) | FT450 | |
TYPE | Not Available | Current sinking | Not Available | |
MAX. VOLTAGE | 36 Vdc | |||
MAX. CURRENT | 100 mA | |||
MAX. FREQUENCY | 6.5 Hz | |||
PULSE WIDTH | 100 ms | |||
ISOLATION | 300 V |
For More Information and Price: Seametrics FT Series FT430/440/450 Rate/Total Indicator