Bamo Variable area flow metre C6/C5-250

Bamo Variable area flow metre C6/C5-250

  • Magnetic movement transmission
  • Indirect reading
  • Scales
    in water: 2.5 to 63000 L/h
    in air: 0.08 to 1000 Nm3/h
  • Threaded or flange connections
  • Options:
    LCD digital display for flow rate and totalization
    Hart protocol, 4-20 mA output
    1 or 2 adjustable alarm contacts
    ATEX certification,
    EEx ia IIC T6 / EEx d IIB T4
Kofloc FCC4000-3660-18SW Flow Compo Compact Handy Mass Flow Control (4)
Kofloc FCC4000-3660-18SW Flow Compo Compact Handy Mass Flow Control (4)

Descriptions Bamo Variable area flow metre C6/C5-250

These flow-metres are designed for gases.
Viscosity variations have less effect on results thanks to a specific profile of the diver.
The transmission of the diver position to the display is magnetically operated.
The small distances between the connections allow an easy location in a small volume.
A dumper option is available for low nominal pressures where pulses on pressure could affect the accuracy.
As options there are a transmitter 4-20 mA two wires model and alarm contacts.
For ATEX area, two versions are certified, intrinsically safe EEx ia and explosion proof EEx d.

PRINCIPLE Bamo Variable area flow metre C6/C5-250

For a correct operation, the flow must be vertical and upward.
The gas passes through a diaphragm pushing a conical. The diver position is at the equilibrium point between the kinetic energy due to the speed of the fluid and the diver weight, profile and diaphragm geometry.
– Each balance point corresponds to a flow rate value.
– Flow rate transmission is done with a magnetic transmission.

Benefits & Features Bamo Variable area flow metre C6/C5-250

Scale range: 1 to 10
Analogical scale length: 80 mm
Accuracy: +/- 1.5% full scale (standard)
Repeatability: 0.5% full scale
Maximal pressure: 40 bar (higher pressures on request)

Temperature limits:
-10 … +150°C without alarm contacts
-10 … +100°C with alarm contacts
-30 … +300°C high temperature version (with and without alarm contacts)

Process connections: Flanges PN 16 UNI 2223/29 (standard); threads BSP, NPT, Triclamp
Wetted parts: Stainless steel 316 L, PTFE – on request: Titanium, Hastelloy C
Display housing: Cast aluminium, epoxy painted RAL 7001
Protection: IP 67
OPTIONS: Inductive contacts (adjustable all along the scale) with 8 V CC power supply

Indicator with transmitter

Scale range: 1 to 10
Analogical scale length: 80 mm
Accuracy: +/- 1% full scale (standard)
Repeatability: 0.5% full scale
Programmable display: LCD, 8 digits (flow rate, %, totalization)
Response time: < 0.5 s (only the electronic)
Analogical output: 4-20 mA, 2 wires
Hart protocol transmission: optional
Main power: 24 V DC +/-10%
Alarm contacts: optional, 1 or 2 adjustable contacts
Maximal pressure: 40 bar

Temperature limits:
-10 … +90°C without alarm contacts
-10 … +90°C with alarm contacts
-30 … +300°C high temperature version (with and without alarm contacts)

Process connections: Flanges PN 16 UNI 2223/29 (standard); threads BSP, NPT, Triclamp
Wetted parts: Stainless steel 316 L, PTFE – on request: Titanium, Hastelloy C
Display housing: Cast aluminium, epoxy painted RAL 7001
Protection: IP 67

OPTIONS:
ATEX Certification EEx ia IIC T6 (Intrinsically safe)
ATEX Certification EEx d IIB T4 (Explosion proof)

Source : www.bamo.fr