West Control Solutions delivers a specialized suite of thyristor power controllers engineered to optimize thermal management through exceptional durability, surge resistance, and high-temperature stability.

The compact design and inexpensive wiring expenses are just two of the many features that West Control Solutions’ single, double, and triple phase power controllers have to offer. Additional features include quick access to internal fuses, heater break alert, zero crossing or burst firing mode, and more. There are additional alternatives for certifications like CE and UL.
We have the appropriate thyristor power controller to satisfy your precise needs, regardless of the load’s constant or variable resistance, inductive or transformer coupling, single or three-phase. Thyristor units come in a variety of sizes up to 2600A and 690Vac, with a starting point of 3A.
Descriptions of West Control Solution Relay M – 1PH Thyristor Power Controller
A variety of thyristor power controllers made to switch single-phase loads are offered by West Control Solutions. These thyristor units are perfect for transformer and inductive loads, as well as conventional or variable resistive loads.
With a DC linear input, front panel display, and RS485 communications as standard, Relay M-1PH = Time proportioned burst firing.
Specification of West Control Solution Relay M – 1PH Thyristor Power Controller
- Single Phase
- 24Vac to 690Vac Supply
- DC logic (SSR)
- 4-20mA or 0-10V DC linear inputs
- 10K Pot or RS485 Comms input
- Zero Crossing
- Single Cycle
- Burst Firing
- Soft Start + Burst Firing
- Delayed Triggering + Burst Firing
- Phase Angle, Soft Start + Phase Angle
Benefits & Features of West Control Solution Relay M – 1PH Thyristor Power Controller
- RS485 Comms
- MODBUS Protocol Standard
- Frontal Key Pad to configure the unit and to read V, I, and Power
- Configurability via RS485, USB Port, and frontal Key Pad
- Microprocessor-based electronic circuit fully isolated from power
- Universal input signal: RS485,Pot, Analog and SSR
- Configurable Control Mode: V, I, V2, and VxI
- Heather Break alarm to diagnose partial or total load failure and Thyristor Short circuit
- Digital input configurable
- Fuse and Fuse Holder Standard
- Current transformer integrated in the Fuse Holder
- Comply with EMC, cUL pending
- IP20 Protection
- DIN RAIL mounting